Plan Review Details - Permit 14081140
Plan Review Stops For Permit 14081140
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-10-03 Cont ID  
Sent By JWITMER Date 2014-10-03 Time 09:57 Rev Time 0.00
Received By jwitmer Date 2014-10-03 Time 09:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-08-28 Cont ID  
Sent By jwitmer Date 2014-08-28 Time 09:45 Rev Time 0.00
Received By jwitmer Date 2014-08-28 Time 09:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-10-17 Cont ID  
Sent By DHAYES Date 2014-10-17 Time 15:09 Rev Time 0.00
Received By dhayes Date 2014-10-17 Time 14:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-09-08 Cont ID  
Sent By dhayes Date 2014-09-08 Time 13:15 Rev Time 0.00
Received By dhayes Date 2014-09-08 Time 12:57 Sent To  
Notes
2014-09-08 13:15:14DATE: 9/8/2014
 PROJECT: SUITE 302 BANYAN BUILDING
 PERMIT#: 14081140
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) THE WIRE INDICATED AS FEEDING PANEL MDP3 IS NOT
 APPROVED FOR 1200AMPS. PROVIDE A PANEL SCHEDULE AND A
 LOAD CALCULATION FOR PANEL MDP3. WPB AMENDMENTS TO THE
 FBC SECTION 107.3.5
  
 2) PROVIDE MANUFACTURER SPECIFICATIONS ON THE FLOOR BOX
 SPECIFIED FOR THE CONFERANCE ROON AND EXECUTIVE OFFICE.
 BOXES LISTED SPECIFICALLY FOR THIS APPLICATION SHALL BE
 USED FOR RECEPTACLES LOCATED IN THE FLOOR. NEC
 314.27(C).
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO
 SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED
 SHEETS FOR COMPARATIVE REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-10-07 Cont ID  
Sent By PLEDUC Date 2014-10-07 Time   Rev Time 0.00
Received By pleduc Date 2014-10-06 Time 12:49 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-08-29 Cont ID  
Sent By pleduc Date 2014-08-29 Time   Rev Time 0.00
Received By pleduc Date 2014-08-28 Time 15:12 Sent To  
Notes
2014-08-29 09:52:27THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE
 FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND
 COMPLIANCE.
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-10-17 Cont ID  
Sent By dhayes Date 2014-10-17 Time 15:09 Rev Time 0.00
Received By dhayes Date 2014-09-25 Time 17:40 Sent To  
Notes
2014-09-26 17:40:29B23

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-08 Cont ID  
Sent By rmcdouga Date 2014-09-08 Time 13:54 Rev Time 0.00
Received By hmoser Date 2014-08-26 Time 16:29 Sent To  
Notes
2014-08-26 16:29:50B25

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-10-03 Cont ID  
Sent By HMOSER Date 2014-10-03 Time 09:57 Rev Time 0.00
Received By jwitmer Date 2014-10-03 Time 09:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-09-08 Cont ID  
Sent By hmoser Date 2014-09-08 Time 13:52 Rev Time 0.00
Received By hmoser Date 2014-09-08 Time 13:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-08-28 Cont ID  
Sent By jwitmer Date 2014-08-28 Time 09:45 Rev Time 0.00
Received By jwitmer Date 2014-08-28 Time 09:45 Sent To  
Notes
***NONE***