Plan Review Details - Permit 14081140
Plan Review Stops For Permit 14081140 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-10-03 |
|
|
Cont ID |
|
Sent By |
JWITMER |
Date |
2014-10-03 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-10-03 |
Time |
09:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2014-08-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-08-28 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-08-28 |
Time |
09:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-10-17 |
|
|
Cont ID |
|
Sent By |
DHAYES |
Date |
2014-10-17 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-10-17 |
Time |
14:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-09-08 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-08 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-08 |
Time |
12:57 |
Sent To |
|
|
Notes |
2014-09-08 13:15:14 | DATE: 9/8/2014 | | PROJECT: SUITE 302 BANYAN BUILDING | | PERMIT#: 14081140 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | 1) THE WIRE INDICATED AS FEEDING PANEL MDP3 IS NOT | | APPROVED FOR 1200AMPS. PROVIDE A PANEL SCHEDULE AND A | | LOAD CALCULATION FOR PANEL MDP3. WPB AMENDMENTS TO THE | | FBC SECTION 107.3.5 | | | | 2) PROVIDE MANUFACTURER SPECIFICATIONS ON THE FLOOR BOX | | SPECIFIED FOR THE CONFERANCE ROON AND EXECUTIVE OFFICE. | | BOXES LISTED SPECIFICALLY FOR THIS APPLICATION SHALL BE | | USED FOR RECEPTACLES LOCATED IN THE FLOOR. NEC | | 314.27(C). | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | SHEETS FOR COMPARATIVE REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2014-10-07 |
|
|
Cont ID |
|
Sent By |
PLEDUC |
Date |
2014-10-07 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-10-06 |
Time |
12:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2014-08-29 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-08-29 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-08-28 |
Time |
15:12 |
Sent To |
|
|
Notes |
2014-08-29 09:52:27 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE | | FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND | | COMPLIANCE. | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | CONSTRUCTION PERIOD. | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | AND COMPLETE PROTECTION IS RETURNED. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-10-17 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-10-17 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-25 |
Time |
17:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-09-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-09-08 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-08-26 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2014-10-03 |
|
|
Cont ID |
|
Sent By |
HMOSER |
Date |
2014-10-03 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-10-03 |
Time |
09:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2014-09-08 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2014-09-08 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-09-08 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2014-08-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-08-28 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-08-28 |
Time |
09:45 |
Sent To |
|
|
Notes |
|
|
|