Plan Review Details - Permit 14081116
Plan Review Stops For Permit 14081116
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-11-24 Cont ID  
Sent By jwitmer Date 2014-11-24 Time 14:48 Rev Time 0.00
Received By jwitmer Date 2014-11-24 Time 13:35 Sent To  
Notes
2014-11-24 14:23:56BUILDING PLAN REVIEW
 PERMIT: 14081116
 ADD: 444 W. RAILROAD AVE.
 CONT: CHANDLER CONSTRUCTION
 TEL: (561)791-6934
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. NOV. 24/2014
 ACTION: PASSED
  
 1) DEFERRED SUBMITTALS, PRODUCT APPROVAL TO BE
 SUBMITTED AFTER PERMIT ISSUANCE. 2010 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE
 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B), WALL LOUVERS,
  
 3) DEFERRED SUBMITTALS ARE TO BE REVIEWED BY THE
 DESIGNER OF RECORD BEFORE SUBMITTING TO THE BUILDING
 DEPARTMENT. 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC..
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-09-03 Cont ID  
Sent By jwitmer Date 2014-09-03 Time 14:06 Rev Time 0.00
Received By jwitmer Date 2014-09-03 Time 13:30 Sent To  
Notes
2014-09-03 13:51:03BUILDING PLAN REVIEW
 PERMIT: 14081116
 ADD: 444 W. RAILROAD AVE.
 CONT: CHANDLER CONSTRUCTION
 TEL: (561)791-6934
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 03/2014
 ACTION: DENIED
  
 1) SHEET A100 & S1 BOTH INDICATE A NEW ENCLOSED TENANT
 SPACE WITH NEW EXTERIOR DOOR OPENINGS AND PRESSURES.
 PLEASE PROVIDE THE WIND DESIGN CRITERIA AND ASOCIATED
 PRESSURES. 2010 FBC-B 1609.1.1 DETERMINATION OF WIND
 DESIGN- CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 1.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 1.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 1.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 1.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 1.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE
 TABLE 1609.2(2) .
  
 2) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B), WALL LOUVERS,
  
 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 4) SHEET A100 SHEET INDICATES THIS TENANT SPACE IS TO
 BE STORAGE, PLEASE SPECIFY THE TYPE OF STORAGE, S1, S2
 OR IS THIS AREA GOING TO BE USED FOR THE STORAGE OF
 VEHICLES, BEING A ENCLOSED GARAGE REQUIRING VENTILATION
 TO TTHE 2010 FBC-M 406.4.2 VENTILATION. A MECHANICAL
 VENTILATION SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH
 THE FLORIDA BUILDING CODE, MECHANICAL.
  
 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-09-16 Cont ID  
Sent By rlecky Date 2014-09-16 Time 13:35 Rev Time 0.00
Received By rlecky Date 2014-09-16 Time 12:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-11-06 Cont ID  
Sent By pleduc Date 2014-11-06 Time   Rev Time 0.00
Received By pleduc Date 2014-11-06 Time 15:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-08-28 Cont ID  
Sent By pleduc Date 2014-08-28 Time   Rev Time 0.00
Received By pleduc Date 2014-08-28 Time 15:13 Sent To  
Notes
2014-08-28 15:51:46THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 DUE TO THE NATURE OF THE REMODEL AND OCCUPANCY CHANGE,
 AN EVALAUTION OF THE FIRE ALARM AND FIRE SPRINKLER IS
 REQUIRED.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-12-01 Cont ID  
Sent By skennedy Date 2014-12-01 Time 15:00 Rev Time 0.00
Received By skennedy Date 2014-11-04 Time 09:02 Sent To  
Notes
2014-11-05 09:02:30C26
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-24 Cont ID  
Sent By skennedy Date 2014-09-24 Time 09:50 Rev Time 0.00
Received By skennedy Date 2014-08-26 Time 15:28 Sent To  
Notes
2014-09-24 09:46:28TO STEVE KENNEDY.
2014-08-26 15:28:44C26
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2014-09-03 Cont ID  
Sent By jwitmer Date 2014-09-03 Time 11:58 Rev Time 0.00
Received By jwitmer Date 2014-09-03 Time 11:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-09-22 Cont ID  
Sent By rbergsma Date 2014-09-22 Time   Rev Time 1.25
Received By rbergsma Date 2014-09-22 Time   Sent To  
Notes
2014-09-22 13:11:11THIS RENOVATION MUST CONTINUE TO COMPLY WITH FBC-M
 404.1, 404.2 AND 404.3
 A TEST AND BALANCE MAY BE REQUESTED

Review Stop Z ZONING
Rev No 2 Status P Date 2014-12-01 Cont ID  
Sent By aaponte Date 2014-12-01 Time 15:07 Rev Time 0.00
Received By aaponte Date 2014-12-01 Time 15:07 Sent To  
Notes
2014-12-01 15:07:46PROVISO: DRIVEWAY SHALL NOT BE USED FOR PARKING OR
 LOADING.
2014-12-01 15:01:05APPROVED BY AAPONTE

Review Stop Z ZONING
Rev No 1 Status F Date 2014-09-24 Cont ID  
Sent By aaponte Date 2014-09-24 Time 09:35 Rev Time 0.00
Received By aaponte Date 2014-09-24 Time 09:34 Sent To  
Notes
2014-09-24 09:45:561. NEW PEDESTRIAN DOOR ON RAILROAD AVENUE WILL BE
 BLOCKED BY A UTILITY PIPE. DOOR NEEDS TO BE MOVED
 TOWARDS THE SOUTH OF THE OPENNING.
 2. EXISING OPENING SHALL REMAINED, PLEASE MODIFY TO
 ALLOW NEW PEDESTRIAN DOOR BUT MAINTAIN THE WINDOW.
 3.THE LAST PARKING SPACE WITHIN THE 1ST FLOOR PARKING
 AREA SHALL BE RESERVED FOR TURN AROUND ONLY. PLEASE
 MARK THE SPACE AS SUCH ON THE GROUND.
 4.PLEASE PROVIDE A SURVEY CONFIRMING THE NEW EXIT DOOR
 ON EAST ELEVATION DOES NOTENCROACH INTO THE FEC
 PROPERTY. IS THIS EMERGENCY EXIT PROPOSED THROUGH THE
 FEC PROPERTY?
 5. PLEASE PROVIDE A TABLE INDICATING THE TOTAL NUMBER
 OF PARKING SPACES ORIGINALLY APPROVED FOR THE PROJECT
 AND THE PROPOSED REDUCTION.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.
2014-09-11 14:55:099/11/14


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved