Plan Review Details - Permit 14081026
Plan Review Stops For Permit 14081026
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-01-07 Cont ID  
Sent By jwitmer Date 2015-01-07 Time 15:29 Rev Time 0.00
Received By jwitmer Date 2015-01-05 Time 12:00 Sent To  
Notes
2015-01-05 13:45:24IN REVIEW, WAITING FOR 3RD SET OF PLANS, THRESHOLD
 PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-11-19 Cont ID  
Sent By jwitmer Date 2014-11-19 Time 11:25 Rev Time 0.00
Received By jwitmer Date 2014-11-17 Time 11:50 Sent To  
Notes
2014-11-19 11:24:16BUILDING PLAN REVIEW
 PERMIT: 14081026
 ADD: 222 LAKEVIEW AVE.
 CONT: FASTRACK
 TEL: (561)304-7881
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2ND REVIEW
 DATE: WED. NOV. 19/2014
 ACTION: DENIED
  
 1) COMPLIED.
  
 2) THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) "
 THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH
 HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN
 THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
  
 2A) COMPLIED.
 SPECIAL INSPECTOR PLAN. P 109.3.6.1 THE ENFORCING
 AGENCY SHALL REQUIRE A SPECIAL INSPECTOR TO PERFORM
 STRUCTURAL INSPECTIONS ON A THRESHOLD BUILDING PURSUANT
 TO A WRITTEN STRUCTURAL INSPECTION PLAN PREPARED BY THE
 ENGINEER OF RECORD. THE STRUCTURAL INSPECTION PLAN MUST
 BE SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE
 ISSUANCE OF A BUILDING PERMIT FOR THE CONSTRUCTION OF A
 THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL
 INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION
 PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE
 ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED
 DOCUMENTS. 3 SETS OF DOCUMENTS WILL BE REQUIRED.
  
 2B) 2ND REQUEST. NOTE: 1) ON THE SPECIAL INSPECTOR
 FORMS PAGE 4 OF 6, THE CERTIFIED INSPECTION COM. IS NOT
 FILLED OUT OR NOTIRIZED.
 2) ON THE SPECIAL INSPECTOR FORMS PAGE 5 OF 6 THE
 CONTRACTOR NAME IS NOT FILLED IN OR NOTIRIZED.
 THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S
 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS
 REQUIRED BY THIS CODE. THRESHOLD INSPECTOR FORM WILL BE
 REQUIRED TO BE FILED OUT BEFORE PERMIT ISSUANCE CAN
 OCCUR. CONTACT KEN CONRAD MANAGER OF THE SPECIAL
 INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER
 INFORMATION.
  
 2C)COMPLIED.
 THRESHOLD BLDG, REQUIRED STATEMENT:
 W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE
 LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE.
  
 2D) 2ND REQUEST. THE CONTRACTOR WILL PRODUCE A JOB
 SUMMARY OR HISTORY FOR THIS TYPE OF CONSTRUCTION.
 THIS MAY BE SUBMITTED TO KEN CONRAD BY E-MAIL. KEN
 CONRAD: [email protected]
  
 2E) COMPLIED.
 FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' OF
 INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME'
 MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED
 HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL
 REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, AN
 INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES
 WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST
 MEETING THE ABOVE CRITERIA.
 CONTACT KEN CONRAD
 TEL: 561-805-6666
 E-MAIL: [email protected]
  
 2F) PROVISO:109.3.6 THRESHOLD BUILDINGS, OPERATING
 GUIDELINES FOR THRESHOLD INSPECTORS #26. ASSURE THAT
 THE DESIGNER HAS REQUIRED ON THE PLANS OR
 SPECIFICATIONS ONE MATERIAL, APPROVED FOR FIRE STOPPING
 PENETRATIONS, FOR WALLS AND CEILINGS.
  
 2G) PROVISO: PLEASE CALL THE CITY OF WEST PALM BEACHS
 AUTOMATED TELEPHONE INSPECTIONS LINE (561) 805-6700)
 FOR IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE
 INSPECTIONS.
  
 3) 2ND REQUEST. THE BUILDING SHEETS A3.2 AND MECHANICAL
 SHEETS M.2 BOTH INDICATE REQUIREMENTS FOR PRODUCT
 APPROVALS TO BE SUBMITTED.
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 RULE 9N-3(31)(C) WALL LOUVERS
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 4) 2ND REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE
 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC..
  
 5-7)COMPLIED.
  
 8) 2ND REQUEST!!!!!! REMOVE ALL VOIDED
 SHEETS!!!!!!!!!!! WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE ANY VIODED SHEETS &
 REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-08-27 Cont ID  
Sent By jwitmer Date 2014-08-27 Time 11:06 Rev Time 0.00
Received By jwitmer Date 2014-08-27 Time 08:48 Sent To  
Notes
2014-08-27 11:04:12BUILDING PLAN REVIEW
 PERMIT: 14081026
 ADD: 222 LAKEVIEW AVE.
 CONT: FASTRACK
 TEL: (561)304-7881
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: WED. AUG. 27/2014
 ACTION: DENIED
  
 1) THIS IS A HIGHRISE BUILDING, THE 2010 FBC-B 708.14.1
 REQUIRES ELEVATOR LOBBIES EVEN IF THIS PORTION OF THE
 BUILDING IS ONLY 5 STORIES TALL OR MEET ONE OF THE
 SEVEN EXCEPTIONS, THIS IS CONSIDERED NEW WORK. 2010
 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING. THE M3 SHEET
 DOES SHOW SF-1 FAN PRESSURIZING THE ELEVATOR SHAFTWAY.
 THE SHEET M2 NOTE2 ONCE THE SMOKE ALARM CLOSES VANT #
 1, THE VENTS LABELED # 2 WILL OPEN ON ACTUATION OF
 SMOKE ALARM OTHERWISE THEY ARE SET AND OPERATE AS A
 BAROMETER PRESSURE SENSOR.
  
 2) THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) "
 THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH
 HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN
 THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
  
 2A) 109.3.6.1 THE ENFORCING AGENCY SHALL REQUIRE A
 SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON
 A THRESHOLD BUILDING PURSUANT TO A WRITTEN STRUCTURAL
 INSPECTION PLAN PREPARED BY THE ENGINEER OF RECORD. THE
 STRUCTURAL INSPECTION PLAN MUST BE SUBMITTED TO THE
 ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING
 PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING.
 THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO
 PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO
 THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR
 COMPLIANCE WITH THE PERMITTED DOCUMENTS. 3 SETS OF
 DOCUMENTS WILL BE REQUIRED.
  
 2B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S
 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS
 REQUIRED BY THIS CODE. THRESHOLD INSPECTOR FORM WILL BE
 REQUIRED TO BE FILED OUT BEFORE PERMIT ISSUANCE CAN
 OCCUR. CONTACT KEN CONRAD MANAGER OF THE SPECIAL
 INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER
 INFORMATION.
  
 2C) THRESHOLD BLDG, REQUIRED STATEMENT:
 W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE
 LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE.
  
 2D) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR
 HISTORY FOR THIS TYPE OF CONSTRUCTION.
 THIS MAY BE SUBMITTED TO KEN CONRAD BY E-MAIL. KEN
 CONRAD: [email protected]
  
 2E) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME'
 OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE
 RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS
 SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE
 WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED,
 AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES
 WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST
 MEETING THE ABOVE CRITERIA.
 CONTACT KEN CONRAD
 TEL: 561-805-6666
 E-MAIL: [email protected]
  
 2F) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES
 FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER
 HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE
 MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR
 WALLS AND CEILINGS.
  
 2G) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED
 TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR
 IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE
 INSPECTIONS.
  
 3) THE BUILDING SHEETS A3.2 AND MECHANICAL SHEETS M.2
 BOTH INDICATE REQUIREMENTS FOR PRODUCT APPROVALS TO BE
 SUBMITTED.
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 RULE 9N-3(31)(C) WALL LOUVERS
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 5) NEITHER THE ARCHITECTURAL NOR STRUCTURAL SHEETS
 PROVIDE THE WIND DESIGN CRITERIA FOR THE NEW ELEVATOR
 PENTHOUSE ROOM NOR LOUVERS ONTHE NEW PENTHOUSE. 2010
 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- CHAPTER 6
 OF ASCE 7-10.
  
 6) SHEET A3.2 DETAIL # A1 SHOWS THIS ELEVATOR TO USE A
 HYDROLIC ELEVATOR, PLEASE PROVIDE CODE COMPLIANCE WITH
 3011.1(1-4) ELECTROLYSIS PROTECTION FOR UNDERGROUND
 HYDRAULIC ELEVATOR CYLINDERS. ALL NEWLY INSTALLED
 UNDERGROUND HYDRAULIC PRESSURE CYLINDERS SHALL BE
 ENCASED IN OUTER PLASTIC CONTAINMENT TO MINIMIZE
 ELECTROLYTIC CORROSION BETWEEN THE METAL CYLINDER AND
 GROUND CATHODE.
  
 7) SHEET M3 SHOWS A NEW ROOF TOP CURB FOR NEITHER THE
 STRUCTURAL SHEETS NOR MECHANICAL SHEETS SHOW THE METHOD
 OF ATTACHMENT OF THE CURB TO THE STRUCTURAL ROOF NOR
 THE FAN TO THE CURB. 2010 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 : WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-01-21 Cont ID  
Sent By tlarge Date 2015-01-21 Time 09:42 Rev Time 0.00
Received By dhayes Date 2015-01-21 Time 09:42 Sent To P
Notes
2015-01-21 09:43:05TO T. LARGE DESK.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-09-03 Cont ID  
Sent By dhayes Date 2014-09-03 Time 12:44 Rev Time 0.00
Received By dhayes Date 2014-09-03 Time 12:07 Sent To  
Notes
2014-09-03 13:01:32DATE: 9/3/2014
 PROJECT: ELEVATORS 9 AND 10
 PERMIT#: 14081026
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 1ST ELECTRICAL PLAN REVIEW
 ACTION: PROVISO
  
 A LICENSED ELECTRICAL CONTRACTOR IS REQUIRED FOR
 APPLICATION AND ISSUANCE OF THE ELECTRICAL PERMIT.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2014-12-16 Cont ID  
Sent By pleduc Date 2014-12-16 Time   Rev Time 0.00
Received By pleduc Date 2014-12-16 Time 11:10 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-10-29 Cont ID  
Sent By pleduc Date 2014-10-29 Time   Rev Time 0.00
Received By pleduc Date 2014-10-29 Time 14:17 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2014-08-25 Cont ID  
Sent By pleduc Date 2014-08-25 Time   Rev Time 0.00
Received By pleduc Date 2014-08-25 Time 13:21 Sent To  
Notes
2014-08-25 14:48:27THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE PROPOSED PLAN DOES NOT INDICATE THE DESIGNATION OF
 AN ELEVATOR LOBBY AND SMOKE PROTECTION ON ANY FLOOR
 LEVEL.
  
 NFPA 101 FLORIDA, 2010 EDITION
  
 7.2.13 ELEVATORS
 7.2.13.3 ELEVATOR LOBBY EVERY FLOOR SERVED BY THE
 ELEVATOR SHALL HAVE AN ELEVATOR LOBBY. BARRIERS FORMING
 THE ELEVATOR LOBBY SHALL HAVE A MINIMUM 1-HOUR FIRE
 RESISTIVE RATING AND SHALL BE ARRANGED AS A SMOKE
 BARRIER IN ACCORDANCE WITH SECTION 8.5.
  
 7.2.13.9 ELEVATOR OPERATIONS. ELEVATORS SHALL BE
 PROVIDED WITH FIRE FIGHTERS EMERGENCY OPERATIONS IN
 ACCORDANCE WITH ASME A 17.A/CSA B44, SAFET CODE FOR
 ELEVATORS AND ESCALATORS.
  
 PLEASE RESUBMIT A PLAN THAT INDICATES THE ELEVATOR
 LOBBY, FIRE FIGHTER EMERGENCY OPERATIONS AND THE MEANS
 TO PROVIDE SMOKE PROTECTION.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-01-22 Cont ID  
Sent By tklarge Date 2015-01-22 Time 05:55 Rev Time 0.00
Received By tklarge Date 2015-01-20 Time 09:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-01-08 Cont ID  
Sent By tklarge Date 2015-01-08 Time 09:24 Rev Time 0.00
Received By tklarge Date 2014-12-11 Time 16:49 Sent To  
Notes
2014-12-11 16:48:18B19

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-11-19 Cont ID  
Sent By jwitmer Date 2014-11-19 Time 11:25 Rev Time 0.00
Received By jwitmer Date 2014-10-27 Time 14:21 Sent To  
Notes
2014-10-28 14:22:43SENT TO B-19. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-03 Cont ID  
Sent By dhayes Date 2014-09-03 Time 12:44 Rev Time 0.00
Received By dhayes Date 2014-08-22 Time 11:05 Sent To  
Notes
2014-08-25 11:05:46SENT TO B15 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-01-02 Cont ID  
Sent By hmoser Date 2015-01-02 Time 12:44 Rev Time 0.00
Received By hmoser Date 2015-01-02 Time 12:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-11-06 Cont ID  
Sent By hmoser Date 2014-11-06 Time 11:14 Rev Time 0.00
Received By hmoser Date 2014-11-06 Time 11:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-08-27 Cont ID  
Sent By jwitmer Date 2014-08-27 Time 15:24 Rev Time 0.00
Received By jwitmer Date 2014-08-27 Time 15:24 Sent To  
Notes
2014-08-27 15:25:15BUILDING PLAN REVIEW
 PERMIT: 14081026
 ADD: 222 LAKEVIEW AVE.
 CONT: FASTRACK
 TEL: (561)304-7881
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: WED. AUG. 27/2014
 ACTION: PASSED.
  
 1) THIS IS A HIGHRISE BUILDING, THE 2010 FBC-B 708.14.1
 REQUIRES ELEVATOR LOBBIES EVEN IF THIS PORTION OF THE
 BUILDING IS ONLY 5 STORIES TALL OR MEET ONE OF THE
 SEVEN EXCEPTIONS, THIS IS CONSIDERED NEW WORK. 2010
 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING. THE M3 SHEET
 DOES SHOW SF-1 FAN PRESSURIZING THE ELEVATOR SHAFTWAY.
 THE SHEET M2 NOTE2 ONCE THE SMOKE ALARM CLOSES VANT #
 1, THE VENTS LABELED # 2 WILL OPEN ON ACTUATION OF
 SMOKE ALARM OTHERWISE THEY ARE SET AND OPERATE AS A
 BAROMETER PRESSURE SENSOR.
  
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2015-01-22 Cont ID  
Sent By tklarge Date 2015-01-22 Time 05:55 Rev Time 0.00
Received By tklarge Date 2015-01-21 Time 14:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2015-01-08 Cont ID  
Sent By tklarge Date 2015-01-08 Time 08:59 Rev Time 0.00
Received By tklarge Date 2015-01-08 Time 05:45 Sent To  
Notes
2015-01-08 09:23:16!) THE STANCOR DUPLEX OIL-MINDER SPECIFICATION SHEETS
 CALL OUT DUPLEX PUMPS AND A 55 GAL OIL STORAGE
 CONTAINER BUT THE PLANS ONLY SHOW THE DISCHARGE OF ONE
 PUMP. CLARIFY.
 2) SHOW THE LOCATION OF THE OIL STORAGE CONTAINER AND
 THE CONTROL PANEL ON THE PLANS. WPB AMEND. TO 2010 FBC
 SEC.107.2.1. 2ND REQUEST. THE SHOP DRAWING MENTIONED
 AND SUBMITTED DOES NOT IDENTIFY THE TANKS,
 LOCATION,ETC.
 3) IF THIS IS A TWO PUMP SYSTEM, SUBMIT A PIPING
 DIAGRAM SHOWING THE PIPING, OIL CONTAINER,& DISCHARGE
 POINT.
 WPB AMEND. TO 2010 FBC SEC.107.2.1.
 4) SUBMIT DOCUMENTATION THAT SHOWS THAT THESE
 COMPONENTS ARE CERTIFIED BY A NATIONALLY RECOGNIZED
 INDEPENDENT TESTING LABORATORY AS STATED IN THE STANCOR
 SPECIFICATIONS. WPB AMEND. TO 2010 FBC SEC.107.2.1.
 5) A CHECK VALVE SHALL BE INSTALLED ON THE PUMP SIDE OF
 THE SHUTOFF VALVE PER THE 2010 FPC SEC.712.2.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2014-11-03 Cont ID  
Sent By tklarge Date 2014-11-03 Time 12:38 Rev Time 0.00
Received By tklarge Date 2014-11-03 Time 04:00 Sent To  
Notes
2014-11-03 12:17:211) SHOW THE LOCATION OF THE HOLDING TANK AND CONTROL
 PANEL FOR THIS SYSTEM. WPB AMEND. TO FBC SEC. 107.2.1.
 2) SUBMIT DOCUMENTATION THAT SHOWS THAT THIS UNIT IS
 CERTIFIED BY A NATIONALLY RECOGNIZED INDEPENDENT
 TESTING LABORATORY AS STATED IN THE LITERATURE THAT WAS
 SUBMITTED. WPB AMEND. TO FBC SEC. 107.2.1.
 3) SHT. P-2 - THE PARTIAL PLUMBING RISER READS " SUMP
 PUMP - SEE DETAIL SHT. P-2 - THERE IS NO SUCH DETAIL ON
 SHT. P-2. CLARIFY.
 4) 712.2 VALVES REQUIRED.
 A CHECK VALVE AND A FULL OPEN VALVE LOCATED ON THE
 DISCHARGE SIDE OF THE CHECK VALVE SHALL BE INSTALLED IN
 THE PUMP OR EJECTOR DISCHARGE PIPING BETWEEN THE PUMP
 OR EJECTOR AND THE GRAVITY DRAINAGE SYSTEM. ACCESS
 SHALL BE PROVIDED TO SUCH VALVES. SUCH VALVES SHALL BE
 LOCATED ABOVE THE SUMP COVER REQUIRED BY SECTION 712.1
 OR, WHERE THE DISCHARGE PIPE FROM THE EJECTOR IS BELOW
 GRADE, THE VALVES SHALL BE ACCESSIBLY LOCATED OUTSIDE
 THE SUMP BELOW GRADE IN AN ACCESS PIT WITH A REMOVABLE
 ACCESS COVER.
 THE SUMP PIT SHALL BE FITTED WITH A GAS-TIGHT REMOVABLE
 COVER ADEQUATE TO SUPPORT ANTICIPATED LOADS IN THE AREA
 OF USE. THE SUMP PIT SHALL BE VENTED IN ACCORDANCE WITH
 CHAPTER 9.
 5) SUBMIT MANUF. SPECS FOR THE PUMPS. PUMPS SHALL MEET
 THE CRITERIA OF 2010 FPC TABLE 712.4.2.
  
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-08-27 Cont ID  
Sent By jwitmer Date 2014-08-27 Time 12:26 Rev Time 0.00
Received By jwitmer Date 2014-08-27 Time 12:12 Sent To  
Notes
2014-08-27 12:16:50PLUMBING PLAN REVIEW
 PERMIT: 14081026
 ADD: 222 LAKEVIEW AVE.
 CONT: FASTRACK
 TEL: (561)304-7881
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: WED. AUG. 27/2014
 ACTION: DENIED
  
 1) SHEET P2 NOTE NOTE # 3 INDICATES THE INSTALATION OF
 A STANCOR OIL MINDER. PLEASE PROVIDE THE MANUFACTURER
 SPECIFICATIONS FOR CODE COMPLIANCE WITH 2010 FBC-P
 1003.4 OIL SEPARATORS REQUIRED.
 AT REPAIR GARAGES, CAR-WASHING FACILITIES, AT FACTORIES
 WHERE OILY AND FLAMMABLE LIQUID WASTES ARE PRODUCED AND
 IN HYDRAULIC ELEVATOR PITS, SEPARATORS SHALL BE
 INSTALLED INTO WHICH ALL OIL-BEARING, GREASE-BEARING OR
 FLAMMABLE WASTES SHALL BE DISCHARGED BEFORE EMPTYING
 INTO THE BUILDING DRAINAGE SYSTEM OR OTHER POINT OF
 DISPOSAL.
 EXCEPTION: AN OIL SEPARATOR IS NOT REQUIRED IN
 HYDRAULIC ELEVATOR PITS WHERE AN APPROVED ALARM SYSTEM
 IS INSTALLED.
  
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2014-08-26 Cont ID  
Sent By ajones Date 2014-08-26 Time 13:33 Rev Time 0.00
Received By ajones Date 2014-08-26 Time 13:33 Sent To  
Notes
***NONE***