2014-08-28 08:08:04 | BUILDING PLAN REVIEW |
| PERMIT: 14080918 |
| ADD: 1016 CLARE AVE SUITE # 2 |
| CONT: FRED BLACK & ASSOC |
| TEL: (561)547-4772 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: THURS. AUG. 28/2014 |
| ACTION: DENIED |
| |
| 1) THE PLANS INDICATE THIS TO BE A LEVEL II ALTERATION. |
| PLEASE REVIEW PERMIT # 13110818 THE AREA WHERE THE WORK |
| IS OCCURRING WAS INDICATED AS STORAGE, THIS WILL BE |
| CONSIDERED A CHANGE OF OCCUPANCY UNDER THE 2010 FL |
| EXISTING BUILDING CODE AND REVIEWED TO CHAPTER 9, |
| PLEASE UPDATE PLANS. 2010 EXISTING BUILDING CODE LEVEL |
| II 701.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, |
| COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE |
| REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, : |
| 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS: |
| 107.3.5.1 COMMERCIAL BUILDINGS: |
| 107.3.5.1.1 BUILDING |
| OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS |
| SHALL BE DETERMINED. |
| MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE |
| TABLE 503) |
| OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| OCCUPANCY LOAD : GROSS/ NET LIFE SAFETY PLAN |
| MEANS OF EGRESS :EXITS |
| |
| 2) SHEET A1.0 DOES NOT INDICATE WHERE THE 2ND MEANS OF |
| EGRESS IS LOCATED. THERE IS A NEW DOORWAY CUT BACK INTO |
| WHAT SHOWS AS A SMALL ROOM THEN INTO A STORAGE ROOM, |
| PLEASE REVIEW EGRESS THROUGH MERCANTILE STORAGE ROOMS. |
| 2010 FBC-B 1014.2 EGRESS THROUGH INTERVENING SPACES. |
| EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH |
| THIS SECTION. |
| 1. EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH |
| ADJOINING OR INTERVENING ROOMS OR AREAS, EXCEPT WHERE |
| SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED ARE |
| ACCESSORY TO ONE OR THE OTHER, ARE NOT A GROUP H |
| OCCUPANCY AND PROVIDE A DISCERNIBLE PATH OF EGRESS |
| TRAVEL TO AN EXIT. |
| EXCEPTION: MEANS OF EGRESS ARE NOT PROHIBITED THROUGH |
| ADJOINING OR INTERVENING ROOMS OR SPACES IN A GROUP H, |
| S OR F OCCUPANCY WHEN THE ADJOINING OR INTERVENING |
| ROOMS OR SPACES ARE THE SAME OR A LESSER HAZARD |
| OCCUPANCY GROUP. |
| 4. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE |
| ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES. |
| EXCEPTIONS: |
| 2. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH |
| STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE |
| FOLLOWING ARE MET: |
| |
| 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS |
| THAT FOUND IN THE MAIN RETAIL AREA; |
| |
| 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS |
| THROUGH THE STOCKROOM; |
| |
| 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE |
| EGRESS SIDE; AND |
| |
| 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118 |
| MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED |
| WALLS OR SIMILAR CONSTRUCTION |
| THAT WILL MAINTAIN THE REQUIRED WIDTH AND LEAD DIRECTLY |
| FROM THE RETAIL AREA TO THE EXIT WITHOUT OBSTRUCTIONS. |
| |
| 3) SHEET A1.0 THE RAMP DOES NOT INDICATE HOW COMPLIANCE |
| WITH RAMP EDGE PROTECTION WILL COMPLY. 2010 FL |
| ACCESSIBILITY CODE 405.9. |
| |
| 4) SHEET A1.0 PLEASE PROVIDE HOW COMPLIANCE WITH 2010 |
| FL ACCESSIBILITY CODE 243.1 GENERAL. WHERE SHOOTING |
| FACILITIES WITH FIRING POSITIONS ARE DESIGNED AND |
| CONSTRUCTED AT A SITE, AT LEAST 5 PERCENT, BUT NO FEWER |
| THAN ONE, OF EACH TYPE OF FIRING POSITION SHALL COMPLY |
| WITH 1010. |
| |
| 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |
| |