Plan Review Details - Permit 14080817
Plan Review Stops For Permit 14080817 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-09-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-09-24 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-09-24 |
Time |
15:00 |
Sent To |
|
|
Notes |
2014-09-24 15:00:36 | ****PROVISO**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | OPENING 2 SPECIFIES POWER TAPPER, RECESS TRACK | | THIS HAS BEEN REDLINED TO 7?, WORST CASE FOR ANCHOR | | CHART ON SHEET 11. | | | | SEE SHEET 9. THE RECESS TRACK, DETAL M, REQUIRES | | TAPCONS, 24? SPACING. | | | | PROVISO - INSTALLATION IS TO COMPLY WITH THE | | REQUIREMENTS OF THE PRODUCT APPROVAL. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-09-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-09-03 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-09-03 |
Time |
17:56 |
Sent To |
|
|
Notes |
2014-09-03 18:09:31 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | | | 1. PROVIDE A LIFE SAFETY PLAN. USE OF THE BUILDING | | (OCCUPANCY CLASSIFICATION FBC CHAPTER 3), NUMBER OF | | OCCUPANTS, TRAVEL DISTANCE, EXITING FROM SECOND FLOOR, | | ETC. ARE NOT CLEAR. SEE THE FOLLOWING: | | | | FBC 1003.6, MEANS OF EGRESS CONTINUITY. THE PATH OF | | EGRESS TRAVEL ALONG A MEANS OF EGRESS SHALL NOT BE | | INTERRUPTED BY ANY BUILDING ELEMENT OTHER THAN A MEANS | | OF EGRESS COMPONENT AS SPECIFIED IN THIS CHAPTER. | | OBSTRUCTIONS SHALL NOT BE PLACED IN THE REQUIRED WIDTH | | OF A MEANS OF EGRESS EXCEPT PROJECTIONS PERMITTED BY | | THIS CHAPTER. | | | | THERE IS NO PROVISION IN THE BUILDING CODE FOR BLOCKING | | OF EXITS WITH IMPACT PROTECTION FOR COMMERCIAL | | BUILDINGS (ONLY RESIDENTIAL). THIS IS CONSIDERED ON A | | CASE BY CASE BASIS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-09-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-09-24 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-09-08 |
Time |
18:46 |
Sent To |
|
|
Notes |
2014-09-08 18:39:02 | RE-SUBMITTAL SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-09-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-09-03 |
Time |
18:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-09-03 |
Time |
18:09 |
Sent To |
|
|
Notes |
2014-08-19 08:32:34 | ROUTED TO BUILDING LESS THAN $5000 |
|
|
|