Plan Review Details - Permit 14080802
Plan Review Stops For Permit 14080802 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-08-22 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-08-22 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-08-22 |
Time |
08:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-08-19 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-08-19 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-08-19 |
Time |
09:29 |
Sent To |
|
|
Notes |
2014-08-22 08:34:47 | DATE: 8/19/2014 | | PROJECT: HOPKINS MARINE | | PERMIT#: 14050989, REVISION TRACKING #14080802 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 2ND ELECTRICAL PLAN REVIEW, REVISION TRACKING #14080802 | | ACTION: DENIED | | | | 1)EMERGENCY ILLUMINATION SHALL INCLUDE ALL REQUIRED | | MEANS OF EGRESS LIGHTING, ILLUMINATED EXIT SIGNS, AND | | ALL OTHER LIGHTS SPECIFIED AS NECESSARY TO PROVIDE | | REQUIRED ILLUMINATION. EMERGENCY LIGHTING SYSTEMS SHALL | | BE DESIGNED AND INSTALLED SO THAT THE FAILURE OF ANY | | INDIVIDUAL LIGHTING ELEMENT, SUCH AS THE BURNING OUT OF | | A LAMP, CANNOT LEAVE IN TOTAL DARKNESS ANY SPACE THAT | | REQUIRES EMERGENCY ILLUMINATION. NEC 700.16 | | REVISE PLANS TO INDICATE COMPLIANCE WITH NEC 700.16 | | | | 2) PROVIDE WIND LOAD CALCULATIONS FOR POLE LIGHT IN THE | | PARKING LOT. | | | | 3) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | MANUFACTURERS EQUIPMENT SUBMITTALS, PLANS, AND SHOP | | DRAWINGS AS REQUIRED FOR CCTV, DATA/COM, NETWORK, | | AUDIO/VIDEO, AND SIGNAGE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | ITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | SHEETS FOR COMPARATIVE REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-08-22 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-08-22 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-08-21 |
Time |
08:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-08-19 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-08-19 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-08-18 |
Time |
09:29 |
Sent To |
Z |
|
Notes |
2014-08-19 10:19:16 | DATE: 8/19/2014 | | PROJECT: HOPKINS MARINE | | PERMIT#: 14050989, REVISION TRACKING #14080802 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 2ND ELECTRICAL PLAN REVIEW, REVISION TRACKING #14080802 | | ACTION: DENIED | | | | 1)EMERGENCY ILLUMINATION SHALL INCLUDE ALL REQUIRED | | MEANS OF EGRESS LIGHTING, ILLUMINATED EXIT SIGNS, AND | | ALL OTHER LIGHTS SPECIFIED AS NECESSARY TO PROVIDE | | REQUIRED ILLUMINATION. EMERGENCY LIGHTING SYSTEMS SHALL | | BE DESIGNED AND INSTALLED SO THAT THE FAILURE OF ANY | | INDIVIDUAL LIGHTING ELEMENT, SUCH AS THE BURNING OUT OF | | A LAMP, CANNOT LEAVE IN TOTAL DARKNESS ANY SPACE THAT | | REQUIRES EMERGENCY ILLUMINATION. NEC 700.16 | | REVISE PLANS TO INDICATE COMPLIANCE WITH NEC 700.16 | | | | 2) PROVIDE WIND LOAD CALCULATIONS FOR POLE LIGHT IN THE | | PARKING LOT. | | | | 3) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | MANUFACTURERS EQUIPMENT SUBMITTALS, PLANS, AND SHOP | | DRAWINGS AS REQUIRED FOR CCTV, DATA/COM, NETWORK, | | AUDIO/VIDEO, AND SIGNAGE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | ITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | SHEETS FOR COMPARATIVE REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
|