Plan Review Details - Permit 14080666
Plan Review Stops For Permit 14080666
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status N Date 2014-11-25 Cont ID  
Sent By tklarge Date 2014-11-25 Time 06:19 Rev Time 0.00
Received By tklarge Date 2014-11-25 Time 06:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-11-10 Cont ID  
Sent By shill Date 2014-11-10 Time 17:56 Rev Time 0.00
Received By shill Date 2014-11-10 Time 17:56 Sent To  
Notes
2014-11-10 17:58:35CONTRACTOR PROVIDED ALL INFORMATION FOR FUTURE WORK
 (INSTALLATION OF CAR WASH EQUIPMENT) TO CLARIFY SCOPE
 UNDER THIS PERMIT. AN EMAIL WAS SENT TO THE CONTRACTOR;
 THIS PERMIT IS FOR CONCRETE WORK ONLY AND A SEPARATE
 PERMIT WILL BE REQUIRED FOR THE EQUIPMENT INSTALLATION.
 OR, CONTRACTOR CAN ADJUST VALUE TO INCLUDE CAR WASH
 EQUIPMENT AND ASSOCIATED WORK AND HAVE IT INCLUDED ON
 THIS PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-09-13 Cont ID  
Sent By shill Date 2014-09-13 Time 11:40 Rev Time 0.00
Received By shill Date 2014-09-13 Time 11:40 Sent To  
Notes
2014-09-13 11:46:45****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
 [email protected]
  
 1. FS471, FAC61G15-23.002, TITLE BLOCK REQUIRED FOR
 ENGINEER AND PLANS ARE TO BE SIGNED, SEALED,DATED
 ORIGINALS.
  
 2. SOILS REPORT WILL BE REQUIRED PRIOR TO CONCRETE POUR
 PER ENGINEER, FBC 16.
  
 3. PLANS REFER TO OTHER SHEETS WHICH WERE NOT
 SUBMITTED. PLEASE PROVIDE OR REVISE PLAN TO REMOVE
 REFERENCE.
  
 4. PROVIDE A SITE PLAN SHOWING LOCATION OF PROPOSED
 WORK, FBC 107.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-11-24 Cont ID  
Sent By tklarge Date 2014-11-25 Time 06:19 Rev Time 0.00
Received By sciard Date 2014-11-24 Time 13:47 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2014-10-20 Cont ID  
Sent By cranford Date 2014-10-20 Time 13:25 Rev Time 0.00
Received By cranford Date 2014-10-20 Time 13:24 Sent To P
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2014-09-23 Cont ID  
Sent By Mgonzale Date 2014-09-23 Time   Rev Time 1.00
Received By mgonzale Date 2014-09-23 Time   Sent To I
Notes
2014-09-23 16:14:03PLEASE RESPOND TO COMMENTS IN WRITING:
  
 #1 PROVIDE LOCATION MAP OF EXTENTS OF AREA WHERE
 CONCRETE WILL BE CUT.
  
 #2 NOTE PLANS "CALL 811 BEFORE DIGG"
  
 #3 PLAN IS NOT SIGNED AND SEALED BY A FLORIDA LICENSE
 PROFESSIONAL
  
 #4 PLAN SCALE IS NOT 1/4"=1'-0" IT IS 1/2"=1'-0" (PLAN
 VIEW)
  
 #5 TRENCH DIMENSIONS DO NOT MEASURE OUT TO BE CORRECT
 AS PER SCALE CALLED OUT.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-11-25 Cont ID  
Sent By tklarge Date 2014-11-25 Time 06:19 Rev Time 0.00
Received By tklarge Date 2014-11-25 Time 06:19 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-11-10 Cont ID  
Sent By shill Date 2014-11-10 Time 17:58 Rev Time 0.00
Received By shill Date 2014-10-06 Time 09:48 Sent To  
Notes
2014-10-07 09:49:30RE-SUBMITTAL SENT TO B5 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By mgonzale Date 2014-09-23 Time 16:14 Rev Time 0.00
Received By wlehnhar Date 2014-08-14 Time 14:25 Sent To  
Notes
2014-09-13 11:47:50B13
  
2014-08-14 14:25:29ZONING
  

Review Stop P PLUMBING
Rev No 4 Status N Date 2014-11-25 Cont ID  
Sent By tklarge Date 2014-11-25 Time 06:18 Rev Time 0.00
Received By tklarge Date 2014-11-25 Time 06:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2014-11-07 Cont ID  
Sent By tklarge Date 2014-11-07 Time 10:28 Rev Time 0.00
Received By tklarge Date 2014-11-07 Time 10:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2014-10-21 Cont ID  
Sent By tklarge Date 2014-10-21 Time 14:44 Rev Time 0.00
Received By tklarge Date 2014-10-21 Time 14:44 Sent To  
Notes
2014-10-21 14:47:07THE SUBMITTED PLAN IS ONLY FOR STRUCTURAL. SUBMIT A
 COMPLETE SET OF PLANS FOR THE CAR WASH SYSTEM FOR
 REVIEW. WPB AMEND. TO 2010 FBC SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-09-24 Cont ID  
Sent By tklarge Date 2014-09-24 Time 12:44 Rev Time 0.00
Received By tklarge Date 2014-09-24 Time 12:44 Sent To  
Notes
2014-09-24 12:55:071) THE PLAN REFERS TO OTHER DRAWINGS AND
 SPECIFICATIONS. SUBMIT ALL DRAWINGS AND SPECS FOR THE
 SCOPE OF WORK TO BE DONE UNDER THIS PERMIT APPLICATION.
 WPB AMEND. TO 2010 FB SEC. 107.2.1.
 2) PLANS SHALL BEAR THE TITLE BLOCK, SEAL AND SIGNATURE
 OF THE ENGINEER OF RECORD PER FL. STATUTE 471 & THE FL.
 ADMIN. CODE RULE 61G15-23.002,
 3) SUBMIT A SITE PLAN THAT SHOWS THE LOCATION OF WHERE
 THE WORK IS BEING DONE. WPB AMEND. TO 2010 FBC SEC.
 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2014-10-09 Cont ID  
Sent By sgraham Date 2014-10-09 Time 16:15 Rev Time 0.00
Received By sgraham Date 2014-10-09 Time 16:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2014-08-14 Cont ID  
Sent By sgraham Date 2014-08-14 Time 15:46 Rev Time 0.00
Received By sgraham Date 2014-08-14 Time 15:46 Sent To B
Notes
2014-08-14 15:46:068/14/14 ZONING FAILED
  
 1. PROVIDE TWO UP TO DATE SURVEYS OF THE PROPERTY,
 HIGHLIGHT THE AREA OF THE NEW CONCRETE.