Plan Review Details - Permit 14080058
Plan Review Stops For Permit 14080058
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-08-27 Cont ID  
Sent By dhayes Date 2014-08-27 Time 10:57 Rev Time 0.00
Received By dhayes Date 2014-08-27 Time 10:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-08-14 Cont ID  
Sent By dhayes Date 2014-08-14 Time 08:09 Rev Time 0.00
Received By dhayes Date 2014-08-11 Time 08:09 Sent To  
Notes
2014-08-14 08:10:08DATE: 8/11/2014
 PROJECT: TESH RESIDENCE
 PERMIT#: 14050296 REVISION#14080058
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 1ST ELECTRICAL PLAN REVIEW ON REVISION
 ACTION: DENIED
  
 1) PROVIDE A PANEL SCHEDULE TO INDICATE NEW AND
 EXISTING LOADS.
 2) PROVIDE A LOAD CALCULATION TO INDICATE EXISTING
 ELECTRICAL PANEL AND SERVICE ARE ADAQUATE TO SERVE
 ADDITIONAL LOADS.
 3) INDICATE CIRCUITRY ON PLANS. IDENTIFY NEW AND
 EXISTING CIRCUITS AND DEVICES. FBC 107.2.1.
 4) PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE
 BATHROOMS. NEC 210.11 (C)(3)
 5) INDICATE STAIRWAY AND LANDINGS FROM 1ST TO 2ND FL.
 6) INCATE FAN BOXES WHERE REQUIRED FOR SUPPORT OF A
 CEILING FAN. NEC 314.27(A)
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT
 /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM
 ITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO
 SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED
 SHEETS FOR COMPARATIVE REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-08-27 Cont ID  
Sent By dhayes Date 2014-08-27 Time 10:57 Rev Time 0.00
Received By dhayes Date 2014-08-21 Time 08:17 Sent To  
Notes
2014-08-22 08:17:51REVISION RE-SUBMITTAL SENT TO DAVID'S DESK FOR REVIEW.
 JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-08-14 Cont ID  
Sent By dhayes Date 2014-08-11 Time 08:10 Rev Time 0.00
Received By dhayes Date 2014-08-01 Time 14:04 Sent To  
Notes
2014-08-05 14:05:08REVISION SENT TO DAVID'S DESK FOR REVIEW. JG.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved