Plan Review Details - Permit 14071032
Plan Review Stops For Permit 14071032
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-08-19 Cont ID  
Sent By rmcdouga Date 2014-08-19 Time 12:25 Rev Time 0.00
Received By rmcdouga Date 2014-08-19 Time 12:25 Sent To  
Notes
2014-08-19 12:27:18THE HEAT PUMP AND CHANNEL DRAIN CUT SHEETS WERE REMOVED
 FROM THE SUBMITTAL DOCUMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-07-30 Cont ID  
Sent By rmcdouga Date 2014-07-30 Time 16:56 Rev Time 0.00
Received By rmcdouga Date 2014-07-30 Time 16:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-08-19 Cont ID  
Sent By dhayes Date 2014-08-19 Time 08:53 Rev Time 0.00
Received By dhayes Date 2014-08-19 Time 08:53 Sent To P
Notes
2014-08-19 08:55:00TO RM'S DESK FOR PLUMBING REVIEW.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-07-30 Cont ID  
Sent By rmcdouga Date 2014-07-30 Time 16:31 Rev Time 0.00
Received By rmcdouga Date 2014-07-30 Time 16:31 Sent To  
Notes
2014-07-30 16:56:092010 FBC / 2008 NEC
  
 DENIED BY ELECTRICAL
  
 1) CUT SHEETS WERE SUBMITTED FOR A HEAT PUMP AND HEAT
 PUMP TIE DOWN. THERE IS NO WIRING DIAGRAM FOR THE HEAT
 PUMP SHOWN ON THE ELECTRICAL DIAGRAM ON PAGE 3 OF THE
 PLANS AND PAGE 1 HAS N/A SPECIFIED FOR HEATER. PLEASE
 CORRECT. CITY AMENDMENTS 107.2.1
  
 2) SPECIFY WHICH ONE OF THE HEAT PUMP MODELS WILL BE
 INSTALLED AND PROVIDE LOAD CALCULATIONS TO SHOW
 ADEQUATE ELECTRIC SERVICE. CITY AMENDMENTS 107.2.1 AND
 NEC 220.40
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2014-07-30 Cont ID  
Sent By rmcdouga Date 2014-07-30 Time 16:23 Rev Time 0.00
Received By rmcdouga Date 2014-07-30 Time 16:23 Sent To  
Notes
2014-07-30 16:24:03NO PERMIT APPLICATION OR GAS PLANS WERE SUBMITTED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-08-19 Cont ID  
Sent By rmcdouga Date 2014-08-19 Time 12:25 Rev Time 0.00
Received By rmcdouga Date 2014-08-18 Time 08:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-07-30 Cont ID  
Sent By rmcdouga Date 2014-07-30 Time 16:56 Rev Time 0.00
Received By rmcdouga Date 2014-07-28 Time 13:29 Sent To  
Notes
2014-07-28 13:29:58ROUTED TO ZONING

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-08-19 Cont ID  
Sent By rmcdouga Date 2014-08-19 Time 12:25 Rev Time 0.00
Received By rmcdouga Date 2014-08-19 Time 12:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-07-30 Cont ID  
Sent By rmcdouga Date 2014-07-30 Time 16:24 Rev Time 0.00
Received By rmcdouga Date 2014-07-30 Time 16:24 Sent To  
Notes
2014-07-30 16:27:372010 FBC
  
 DENIED BY PLUMBING
  
 1) CUT SHEETS WERE SUBMITTED FOR A 32" CHANNEL DRAIN
 AND THE PLANS SPECIFY TWO MAIN DRAINS. PLEASE CLARIFY.
 CITY AMENDMENTS 107.2.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2014-07-28 Cont ID  
Sent By sgraham Date 2014-07-28 Time 16:07 Rev Time 0.00
Received By sgraham Date 2014-07-28 Time 16:07 Sent To B
Notes
***NONE***