Plan Review Details - Permit 14070650
Plan Review Stops For Permit 14070650 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2014-11-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-11-19 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-11-19 |
Time |
12:15 |
Sent To |
|
|
Notes |
2014-11-19 12:46:42 | BUILDING PROVISO: | | ROOF REVIEW TO BE UNDER SEPARATE PERMIT. | 2014-11-04 17:39:39 | B27 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-08-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-08-27 |
Time |
07:07 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-08-27 |
Time |
06:27 |
Sent To |
|
|
Notes |
2014-08-27 07:07:36 | BUILDING PLAN REVIEW | | PERMIT: 14070650 | | ADD: 1101 N TAMARIND AVE. | | CONT: FASTRACK CONSTRUCTION | | TEL: (561)772-8848 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: WED. AUG. 27/ 2014 | | ACTION: DENIED | | | | 1) SHEET A2 INDICATES A 2'-9" A PORTION OF A BOTTOM | | LANDING WITH DETECTABLE WARNING (TRUNCATED DOMES) ON | | THE SURFACE. THIS DEVICE IS ONLY TO BE USED IN | | CONJUNCTION WITH CURB RAMPS SUBJECT TO DEPARTMENT OF | | TRANSPORTATION REGULATION 49 CFR 37.21, WHEN CROSSING | | STREETS, NOT IN PARKING LOTS. 2010 FBC-ACCESSIBILITY | | 406.8. | | | | 1B-E) COMPLIED. | | | | 2) 2ND REQUEST. RESPONSE INDICATES THERE THE CONTRACTOR | | WAS TO SUBMIT A COST BREAKDOWN, NOT INCLUDED IN THIS | | REVIEW. THE COST BREAKDOWN NEEDS TO HAVE THE CONTRACTOR | | LETTERHEAD AND ON A SEPARATE SHEET OF PAPER, NOT PART | | OF THE RESPONCE SHEET. PROVIDE THE BREAK DOWN OF HOW | | $8,450.00 DOLLARS IS GOING TO BE SPENT ON CONCRETE | | APPROACH & SIDEWALKS, PROVIDE THE COST BREAK DOWN ON | | $5,850 DOLLARS HOW MANY DOORS ARE GOING TO BE MADE | | ACCESSIBLE FOR THIS AMOUNT,THE NEXT ITEM ON THE LIST IS | | ACCESSIBLE RESTROOMS. THE LAST ITEM ON THE LIST IS | | PARKING / STRIPPING AND THE CODE AS FAR AS | | DISPEOPORTIONATE COST DOES NOT LIST ADA PASS THROUGH | | WINDOWS UNDER DISPROPORTIONATE COST. | | | | 202.4.1 DISPROPORTIONATE COST. | | ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF | | TRAVEL TO THE ALTERED AREA WILL BE DEEMED | | DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE | | COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE | | PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS | | EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF | | TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING | | AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE | | ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING | | RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, | | ENLARGING TOILET STALLS, INSULATING PIPES, OR | | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS | | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH | | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, | | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT | | TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING | | AN INACCESSIBLE DRINKING FOUNTAIN. | | | | THE EXITING RESTROOM IS NOT CODE COMPLIANT TO THE 2010 | | FL ACCESSIBILITY CODE, PLEASE REVIEW 2010 FL | | ACCESSIBILITY CODE 604.3.2.NOR DOES THE PLANS SHOW ANY | | ELEMENTS FOR A ACCESSIBLE RESTROOM. | | | | 3) SUBMITTED PRODUCT APPROVAL FOR EXTERIOR DOORS IS NOA | | 12-0706.03 PLEASE SHOW (CIRCLE) WHICH THRESHOLD WILL BE | | INSTALLED PAGE 2.1 OF 7 TO MAKE THE BUILDING CODE | | COMPLIANT WITH 2010 FL ACCESSIBILITY CODE 404.2.5. | | | | 4) SEE COMMENT # 2 ABOVE THE COMMENT HAS BEEN | | EXSPANDED. PLEASE REVIEW 2010 FL ACCESSIBILITY CODE, | | SECTIONS 202.4.1 DISPROPORTIONATE COST. ALTERATIONS | | MADE TO PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE | | ALTERED AREA WILL BE DEEMED DISPROPORTIONATE TO THE | | OVERALL ALTERATION WHEN THE COST EXCEEDS 20% OF THE | | COST OF THE ALTERATION TO THE PRIMARY FUNCTION AREA. | | COSTS THAT MAY BE COUNTED AS EXPENDITURES REQUIRED TO | | PROVIDE AN ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) | | COSTS ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE | | AND AN ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS | | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS | | INSTALLING GRAB BARS, ENLARGING TOILET STALLS, | | INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET | | CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING | | ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE | | TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION | | DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV) | | COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE | | DRINKING FOUNTAIN. | | | | 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS | | NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED | | AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST | | OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE | | MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE | | ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN | | CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY | | SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE | | GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN | | ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE | | ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM | | FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV) | | ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING | | FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | ALARMS. | | | | PLEASE MAKE A ITEMIZED LIST WHERE $25,000.00 DOLLARS OF | | ACCESSIBLE UPGRADES (20%) WILL BE MADE TO MAKE THE | | BUILDING ACCESSIBLE TO THE CURRENT 2010 ACCESSIBILITY | | CODE. | | | | | | 5) 2ND REQUEST. NOTICE: CHAPTER 553.80(2)(B) FLORIDA | | STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A | | FEE OF FOUR TIMES THE FEE FOR | | PLAN REVIEW, IF PLANS ARE REJECTED OR MORE TIMES FOR | | REPEATED FAILURE TO CORRECT A CODE VIOLATION. | | | | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. IF APPROVED SHOW APPROVED WITH A | | SHOP DRAWING STAMP, APPROVED OR APPROVED AS NOTED! | | | | 6) NOTE AWNING SHOWN ON THE PLANS WILL BE REVIEWED | | UNDER A SEPARATE PERMIT. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-07-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-07-24 |
Time |
07:51 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-07-24 |
Time |
06:50 |
Sent To |
|
|
Notes |
2014-07-24 07:49:39 | BUILDING PLAN REVIEW | | PERMIT: 14070650 | | ADD: 1101 N TAMARIND AVE. | | CONT: FASTRACK CONSTRUCTION | | TEL: (561)772-8848 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. JULY 24/ 2014 | | ACTION: DENIED | | | | 1) SHEET A2 INDICATES A 2'-9" ACCESSIBLE RAMP WITH | | DETECTABLE WARNING ON THE RAMP. THE RAMP IS LACKING A | | TOP LANDING IN THE DIRECTION OF TRAVEL WITHOUT HAVING | | TO MAKE A 90 DEGREE TURN. PLEASE REVIEW THE FOLLOWING | | 2010 FL ACCESSIBILITY CODE SECTIONS THAT DEAL WITH | | RAMPS. | | 1A) 405.3 CROSS SLOPE. CROSS SLOPE OF RAMP RUNS SHALL | | NOT BE STEEPER THAN 1:48. | | | | 1B) 405.4 FLOOR OR GROUND SURFACES. FLOOR OR GROUND | | SURFACES OF RAMP RUNS SHALL COMPLY WITH 302. CHANGES IN | | LEVEL OTHER THAN THE RUNNING SLOPE AND CROSS SLOPE ARE | | NOT PERMITTED ON RAMP RUNS. | | | | 1C) 405.7 LANDINGS. RAMPS SHALL HAVE LANDINGS AT THE | | TOP AND THE BOTTOM OF EACH RAMP RUN. LANDINGS SHALL | | COMPLY WITH 405.7. | | | | 1D) 05.7.3 LENGTH. THE LANDING CLEAR LENGTH SHALL BE 60 | | INCHES (1525 MM) LONG MINIMUM. | | | | 1E) 405.7.4 CHANGE IN DIRECTION. RAMPS THAT CHANGE | | DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR | | LANDING 60 INCHES (1525 MM) MINIMUM BY 60 INCHES (1525 | | MM) MINIMUM. | | | | 2) THE EXITING RESTROOM IS NOT CODE COMPLIANT TO THE | | 2010 FL ACCESSIBILITY CODE, PLEASE REVIEW 2010 FL | | ACCESSIBILITY CODE 604.3.2.NOR DOES THE PLANS SHOW ANY | | ELEMENTS FOR A ACCESSIBLE RESTROOM. | | | | 3) SUBMITTED PRODUCT APPROVAL FOR EXTERIOR DOORS IS NOA | | 12-0706.03 PLEASE SHOW (CIRCLE) WHICH THRESHOLD WILL BE | | INSTALLED PAGE 2.1 OF 7 TO MAKE THE BUILDING CODE | | COMPLIANT WITH 2010 FL ACCESSIBILITY CODE 404.2.5. | | | | 4) PLEASE REVIEW 2010 FL ACCESSIBILITY CODE, SECTIONS | | 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE TO | | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED | | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL | | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE | | ALTERATION TO THE PRIMARY FUNCTION AREA. COSTS THAT MAY | | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN | | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COSTS | | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN | | ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS | | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS | | INSTALLING GRAB BARS, ENLARGING TOILET STALLS, | | INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET | | CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING | | ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE | | TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION | | DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV) | | COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE | | DRINKING FOUNTAIN. | | | | 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS | | NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED | | AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST | | OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE | | MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE | | ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN | | CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY | | SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE | | GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN | | ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE | | ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM | | FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV) | | ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING | | FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | ALARMS. | | | | PLEASE MAKE A ITEMIZED LIST WHERE $25,000.00 DOLLARS OF | | ACCESSIBLE UPGRADES (20%) WILL BE MADE TO MAKE THE | | BUILDING ACCESSIBLE TO THE CURRENT 2010 ACCESSIBILITY | | CODE. | | | | | | 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 6) NOTE AWNING SHOWN ON THE PLANS WILL BE REVIEWED | | UNDER A SEPARATE PERMIT. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-09-08 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-08 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-08 |
Time |
09:02 |
Sent To |
|
|
Notes |
2014-09-08 09:06:08 | DATE: 9/8/2014 | | PROJECT: E & M LIQUORS | | PERMIT#: 14070650 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 2ND ELECTRICAL PLAN REVIEW | | ACTION: PROVISO | | | | SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | FOR STORE FRONT SIGN. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2014-07-18 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-07-18 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-07-18 |
Time |
12:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2014-11-05 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-11-05 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-11-05 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-08-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-08-19 |
Time |
10:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2014-07-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-07-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-07-25 |
Time |
10:37 |
Sent To |
|
|
Notes |
2014-07-25 12:13:57 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | ON SHEET A-2 IN THE FLOOR PLAN NOTES SECTION IT READS | | "ALL NEW DOORS SHALL BE IN FULL COMPLIANCE WITH THE | | PROVISIONS OF NFPA 101, 24.2.4". THAT SECTION OF THE | | CODE REFERS TO ONE AND TWO FAMILY DWELLINGS AND IS NOT | | APPLICCABLE TO THIS OCCUPANCY. A PROVISO HAS BEEN ADDED | | TO READ "37.2.2.2", REFERING TO MERCANTILE OCCUPANCY. | | | | ON SHEET A-2 IN THE FLOOR PLAN DRAWING, IT READS NEW | | IMPACT RATED DOOR WITH SECURITY SHUTTER ON INSIDE. THE | | SHUTTER SHALL NOT RESTRICT EGRESS AND COMPLY WITH NFPA | | 101, CHAPTER 7. THE FIRE INSPECTOR SHALL CONFIRM | | COMPLIANCE ON FINAL INSPECTION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-11-26 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2014-11-26 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-11-04 |
Time |
16:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-09-16 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2014-09-16 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-08-14 |
Time |
09:55 |
Sent To |
|
|
Notes |
2014-09-16 11:30:00 | FAILED. UNDER "F" CONTRACTOR CONTACTED BY PHONE. | 2014-08-15 09:55:15 | B26 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-08-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-07-29 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-07-18 |
Time |
12:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2014-11-26 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2014-11-26 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-11-26 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2014-08-18 |
|
|
Cont ID |
|
Sent By |
jdariton |
Date |
2014-08-18 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
jdariton |
Date |
2014-08-18 |
Time |
09:52 |
Sent To |
|
|
Notes |
2014-08-18 09:51:41 | 8/18/14 MUST ADDRESS THE PREVIOUS COMMENTS. JDA. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2014-07-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2014-07-29 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-07-29 |
Time |
09:03 |
Sent To |
|
|
Notes |
2014-07-29 10:07:41 | PLAN DENIED | | PROVIDE DUCT AND GRILL SIZE ON NEW EXPOSED DUCT. | | PER SECTION 107 FBC 2010 | | REFER TO SECTION 603.5 NONMETALLIC DUCT | | FYI DO NOT PAINT FIBERGLASS OR FLEX DUCT. | | 2010 FBC (M) . | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2014-11-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-11-19 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-11-19 |
Time |
12:47 |
Sent To |
|
|
Notes |
2014-11-19 12:49:58 | NO PLUMBING WORK, EXISTING RESTROOM IS NOT ACCESSIBLE, | | THE CONTRACTOR USED UP THE 20 % DISPROPORTIONATE COST | | TO ACCESSIBLE ENTRANCE AND ACCESSABLE ALTERED WORK | | AREAS BEFORE BEFORE GETTING TO THE RESTROOMS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2014-08-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-08-27 |
Time |
06:31 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-08-27 |
Time |
06:15 |
Sent To |
|
|
Notes |
2014-08-27 06:29:04 | PLUMBING PLAN REVIEW | | PERMIT: 14070650 | | ADD: 1101 N TAMARIND AVE. | | CONT: FASTRACK CONSTRUCTION | | TEL: (561)772-8848 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: WED. AUG. 27/ 2014 | | ACTION: DENIED | | | | RESPONSE INDICATES THERE IS A ITEMIZED LIST FROM THE | | CONTRACTOR IN THIS RESUBMITTAL, NO SUCH SUBMITTAL IN | | PACKAGE!!!!!! | | | | 1 THE EXITING RESTROOM IS NOT CODE COMPLIANT TO THE | | 2010 FL ACCESSIBILITY CODE, PLEASE REVIEW 2010 FL | | ACCESSIBILITY CODE 604.3.2.NOR DOES THE PLANS SHOW ANY | | ELEMENTS FOR A ACCESSIBLE RESTROOM. | | | | 2)) PLEASE REVIEW 2010 FL ACCESSIBILITY CODE, SECTIONS | | 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE TO | | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED | | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL | | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE | | ALTERATION TO THE PRIMARY FUNCTION AREA. COSTS THAT MAY | | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN | | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COSTS | | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN | | ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS | | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS | | INSTALLING GRAB BARS, ENLARGING TOILET STALLS, | | INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET | | CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING | | ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE | | TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION | | DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV) | | COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE | | DRINKING FOUNTAIN. | | | | 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS | | NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED | | AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST | | OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE | | MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE | | ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN | | CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY | | SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE | | GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN | | ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE | | ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM | | FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV) | | ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING | | FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | ALARMS. | | | | PLEASE MAKE A ITEMIZED LIST WHERE $25,000.00 DOLLARS OF | | ACCESSIBLE UPGRADES (20%) WILL BE MADE TO MAKE THE | | BUILDING ACCESSIBLE TO THE CURRENT 2010 ACCESSIBILITY | | CODE. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-07-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-07-24 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-07-24 |
Time |
07:49 |
Sent To |
|
|
Notes |
2014-07-24 07:51:07 | PLUMBING PLAN REVIEW | | PERMIT: 14070650 | | ADD: 1101 N TAMARIND AVE. | | CONT: FASTRACK CONSTRUCTION | | TEL: (561)772-8848 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. JULY 24/ 2014 | | ACTION: DENIED | | | | 1 THE EXITING RESTROOM IS NOT CODE COMPLIANT TO THE | | 2010 FL ACCESSIBILITY CODE, PLEASE REVIEW 2010 FL | | ACCESSIBILITY CODE 604.3.2.NOR DOES THE PLANS SHOW ANY | | ELEMENTS FOR A ACCESSIBLE RESTROOM. | | | | 2)) PLEASE REVIEW 2010 FL ACCESSIBILITY CODE, SECTIONS | | 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE TO | | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED | | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL | | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE | | ALTERATION TO THE PRIMARY FUNCTION AREA. COSTS THAT MAY | | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN | | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COSTS | | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN | | ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS | | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS | | INSTALLING GRAB BARS, ENLARGING TOILET STALLS, | | INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET | | CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING | | ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE | | TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION | | DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV) | | COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE | | DRINKING FOUNTAIN. | | | | 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS | | NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED | | AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST | | OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE | | MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE | | ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN | | CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY | | SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE | | GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN | | ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE | | ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM | | FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV) | | ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING | | FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | ALARMS. | | | | PLEASE MAKE A ITEMIZED LIST WHERE $25,000.00 DOLLARS OF | | ACCESSIBLE UPGRADES (20%) WILL BE MADE TO MAKE THE | | BUILDING ACCESSIBLE TO THE CURRENT 2010 ACCESSIBILITY | | CODE. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
N |
Date |
2014-11-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-11-19 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-11-19 |
Time |
12:46 |
Sent To |
|
|
Notes |
2014-11-19 12:47:33 | BUILDING PROVISO: | | ROOF REVIEW TO BE UNDER SEPARATE PERMIT,SUBMIT PRODUCT | | APPROVALS, TO BE REVIEWED BY THE DESIGNER OF RECORD | | BEFORE SUBMITANCE TO CITY FOR REVIEW. MINIMUM PERMIT | | FEE OF $80.00 SUB-PERMIT. JW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2014-08-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-08-27 |
Time |
07:09 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-08-27 |
Time |
07:09 |
Sent To |
|
|
Notes |
2014-08-27 07:09:49 | ROOFING PLAN REVIEW | | PERMIT: 14070650 | | ADD: 1101 N TAMARIND AVE. | | CONT: FASTRACK CONSTRUCTION | | TEL: (561)772-8848 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: WED. AUG. 27/ 2014 | | ACTION: DENIED | | | | 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 2) TWO (2) ROOFING REPORTS WERE SUBMITTED ONE FOR STEEL | | DECKS AND ONE FOR A CONCRETE DECK, PLEASE PROVIDE THE | | CORRECT REPORT, CIRCLE WHICH SUB-SYSTEM WHICH IS | | INTENDED TO BE INSTALLED. NOTE EACH SUB-SYSTEM HAS HAS | | LISTED A MAXIMUM DESIGN PRESSURE, SOME HAVE A | | LIMITATION #7 ( ENHANCED FASTENING) OTHER HAVE A | | LIMITATION # 9 (MAXIMUM DESIGN PRESSURE). IF ENHANCED | | FASTENING IS CHOSEN A ARCHITECT OR ENGINEER MUST | | PROVIDE THE RAS 117 CALCULATION FOR ZONES 2 & 3 | | .2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.2.1.2 FOR | | ROOF ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION | | DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE | | TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING | | REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE | | RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT | | EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE | | WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE | | OR A STATEMENT BY AN ARCHITECT OR ENGINEER FOR THE | | SPECIFIC SITE MUST BE SUBMITTED WITH THE CONSTRUCTION | | DOCUMENTS. | | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2014-07-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-07-24 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-07-24 |
Time |
07:53 |
Sent To |
|
|
Notes |
2014-07-24 08:01:02 | ROOFING PLAN REVIEW | | PERMIT: 14070650 | | ADD: 1101 N TAMARIND AVE. | | CONT: FASTRACK CONSTRUCTION | | TEL: (561)772-8848 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. JULY 24/ 2014 | | ACTION: DENIED | | | | 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 2) TWO (2) ROOFING REPORTS WERE SUBMITTED ONE FOR STEEL | | DECKS AND ONE FOR A CONCRETE DECK, PLEASE PROVIDE THE | | CORRECT REPORT, CIRCLE WHICH SUB-SYSTEM WHICH IS | | INTENDED TO BE INSTALLED. NOTE EACH SUB-SYSTEM HAS HAS | | LISTED A MAXIMUM DESIGN PRESSURE, SOME HAVE A | | LIMITATION #7 ( ENHANCED FASTENING) OTHER HAVE A | | LIMITATION # 9 (MAXIMUM DESIGN PRESSURE). IF ENHANCED | | FASTENING IS CHOSEN A ARCHITECT OR ENGINEER MUST | | PROVIDE THE RAS 117 CALCULATION FOR ZONES 2 & 3 | | .2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.2.1.2 FOR | | ROOF ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION | | DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE | | TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING | | REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE | | RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT | | EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE | | WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE | | OR A STATEMENT BY AN ARCHITECT OR ENGINEER FOR THE | | SPECIFIC SITE MUST BE SUBMITTED WITH THE CONSTRUCTION | | DOCUMENTS. | | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2014-11-21 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2014-11-21 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-11-21 |
Time |
14:26 |
Sent To |
|
|
Notes |
2014-11-21 14:37:50 | PROVISO: 1. WHEEL STOP ON SOUTH PARKING SPACES SHALL BE | | MOVED 2 FEET INTO THE SPACE. | | 2. PARKING STRIPING DETAIL SHALL FOLLOW CITY STANDARDS | | (SEC 94-485 STALL PAINTING DETAIL) | | 3. PROVIDED SABAL PALMS SHALL BE SPACES ALONG THE WEST | | PROPERTY LINE. | | 4. ANGLE PARKING SHALL MEET THE MINIMUM DIMENSION FOR A | | STALL DEPTH TO PROVIDE AT LEAST 22 FEET DRIVE AISLE. | | 4. A SEPARATE LANDSCAPE AND IRRIGATION PERMIT IS | | REQUIRED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2014-09-16 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2014-09-16 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-09-16 |
Time |
10:06 |
Sent To |
|
|
Notes |
2014-09-16 11:28:09 | 1. ACCORDING TO THE PAPA WEBSITE, THE IMPROVEMENT VALUE | | OF THE PROPERTY IS $34,000, AND THE LISTED VALUE OF THE | | PROPOSED IMPROVEMENTS IS $125,000, EXCEEDING 50% OF THE | | IMPROVEMENT VALUE. THE LANDSCAPE AND PARKING SHALL BE | | UPGRADED TO MEET CODE. | | 2. LANDSCAPE BUFFER ALONG TAMARIND SHALL BE 10 FEET IN | | WIDTH, AND A SHADE TREE SHALL BE PLANTED ON EACH SIDE | | OF PARKING ENTRANCE. | | 3. SHADE TREE SHALL BE PLANTED EVERY 30 FEET ALONG THE | | ENTIRE PERIMETER OF THE PARKING AREA. A HEDGE IS | | REQUIRED ALONG THE ENTIRE PERIMETER OF THE PARKING LOT. | | 4. ALL LANDSCAPE AREAS SHALL BE PROTECTED BY A WHEEL | | STOP OR A CURB. | | 5. SURVEY SHALL BE SIGNED AND SEALED AND AT SCALE. | | 6. CURRENTLY THERE IS A DUMPSTER ON THE SITE NOT SHOWN | | IN THE DRAWINGS. DUMPSTER SHALL BE ENCLOSED AND | | SCREENED WITH AN OPAQUE FENCE OR WALL. A HEDGE SHALL BE | | PROVIDED ALONG THE FENCE OR WALL. PLEASE COORDINATE | | WITH THE SANITATION DEPARTMENT TO ENSURE THE CURRENT | | LOCATION OF THE DUMPSTER IS THE OPTIMAL PICK UP | | LOCATION. (FERDINAND RIVERA 822-2076). | | 7. STRIPING DETAIL DOES NOT REFLECT THE CITY'S STANDARD | | (SEC 94-485), PLEASE UPDATE. | | 8. PARKING SPACES CAN BE REDUCED TO THE MINIMUM | | REQUIRED ACCORDING TO FIGURE XV-2 IN SECTION 94-485 OF | | THE ZONING CODE TO INCREASE THE LANDSCAPE AREAS. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. | 2014-08-26 13:39:28 | 8/25/14 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2014-07-29 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2014-07-29 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-07-29 |
Time |
14:11 |
Sent To |
|
|
Notes |
2014-07-29 14:28:57 | 1. NEW LANDSCAPE SHALL BE INSTALLED AROUND THE SURFACE | | PARKING LOT TO COMPLY WITH CURRENT REQUIREMENTS. SEE | | SEC 94-113(F) OF THE ZONING CODE. | | 2. ALL LANDSCAPED AREAS SHALL BE PROTECTED BY A CURB OR | | A WHEEL STOP. | | 3. PLEASE REVISE PARKING STALL DETAIL TO COMPLY WITH | | CITY REQUIREMENTS (SEC 94-485). | | 4. PLEASE SUBMIT A SURVEY OF THE PROPERTY. | | 5. PLEASE INCLUDE ALL PARKING DIMENSIONS ON SITE PLAN. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. | 2014-07-29 10:52:23 | 7/29/14 ZONING SENT TO AA. SG | 2014-07-25 10:34:46 | 7/25/14 |
|
|
|