Plan Review Details - Permit 14070650
Plan Review Stops For Permit 14070650
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-11-19 Cont ID  
Sent By jwitmer Date 2014-11-19 Time 13:12 Rev Time 0.00
Received By jwitmer Date 2014-11-19 Time 12:15 Sent To  
Notes
2014-11-19 12:46:42BUILDING PROVISO:
 ROOF REVIEW TO BE UNDER SEPARATE PERMIT.
2014-11-04 17:39:39B27
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-08-27 Cont ID  
Sent By jwitmer Date 2014-08-27 Time 07:07 Rev Time 0.00
Received By jwitmer Date 2014-08-27 Time 06:27 Sent To  
Notes
2014-08-27 07:07:36BUILDING PLAN REVIEW
 PERMIT: 14070650
 ADD: 1101 N TAMARIND AVE.
 CONT: FASTRACK CONSTRUCTION
 TEL: (561)772-8848
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. AUG. 27/ 2014
 ACTION: DENIED
  
 1) SHEET A2 INDICATES A 2'-9" A PORTION OF A BOTTOM
 LANDING WITH DETECTABLE WARNING (TRUNCATED DOMES) ON
 THE SURFACE. THIS DEVICE IS ONLY TO BE USED IN
 CONJUNCTION WITH CURB RAMPS SUBJECT TO DEPARTMENT OF
 TRANSPORTATION REGULATION 49 CFR 37.21, WHEN CROSSING
 STREETS, NOT IN PARKING LOTS. 2010 FBC-ACCESSIBILITY
 406.8.
  
 1B-E) COMPLIED.
  
 2) 2ND REQUEST. RESPONSE INDICATES THERE THE CONTRACTOR
 WAS TO SUBMIT A COST BREAKDOWN, NOT INCLUDED IN THIS
 REVIEW. THE COST BREAKDOWN NEEDS TO HAVE THE CONTRACTOR
 LETTERHEAD AND ON A SEPARATE SHEET OF PAPER, NOT PART
 OF THE RESPONCE SHEET. PROVIDE THE BREAK DOWN OF HOW
 $8,450.00 DOLLARS IS GOING TO BE SPENT ON CONCRETE
 APPROACH & SIDEWALKS, PROVIDE THE COST BREAK DOWN ON
 $5,850 DOLLARS HOW MANY DOORS ARE GOING TO BE MADE
 ACCESSIBLE FOR THIS AMOUNT,THE NEXT ITEM ON THE LIST IS
 ACCESSIBLE RESTROOMS. THE LAST ITEM ON THE LIST IS
 PARKING / STRIPPING AND THE CODE AS FAR AS
 DISPEOPORTIONATE COST DOES NOT LIST ADA PASS THROUGH
 WINDOWS UNDER DISPROPORTIONATE COST.
  
 202.4.1 DISPROPORTIONATE COST.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
  
 THE EXITING RESTROOM IS NOT CODE COMPLIANT TO THE 2010
 FL ACCESSIBILITY CODE, PLEASE REVIEW 2010 FL
 ACCESSIBILITY CODE 604.3.2.NOR DOES THE PLANS SHOW ANY
 ELEMENTS FOR A ACCESSIBLE RESTROOM.
  
 3) SUBMITTED PRODUCT APPROVAL FOR EXTERIOR DOORS IS NOA
 12-0706.03 PLEASE SHOW (CIRCLE) WHICH THRESHOLD WILL BE
 INSTALLED PAGE 2.1 OF 7 TO MAKE THE BUILDING CODE
 COMPLIANT WITH 2010 FL ACCESSIBILITY CODE 404.2.5.
  
 4) SEE COMMENT # 2 ABOVE THE COMMENT HAS BEEN
 EXSPANDED. PLEASE REVIEW 2010 FL ACCESSIBILITY CODE,
 SECTIONS 202.4.1 DISPROPORTIONATE COST. ALTERATIONS
 MADE TO PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE
 ALTERED AREA WILL BE DEEMED DISPROPORTIONATE TO THE
 OVERALL ALTERATION WHEN THE COST EXCEEDS 20% OF THE
 COST OF THE ALTERATION TO THE PRIMARY FUNCTION AREA.
 COSTS THAT MAY BE COUNTED AS EXPENDITURES REQUIRED TO
 PROVIDE AN ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I)
 COSTS ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE
 AND AN ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS
 ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS
 INSTALLING GRAB BARS, ENLARGING TOILET STALLS,
 INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET
 CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING
 ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE
 TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION
 DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV)
 COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE
 DRINKING FOUNTAIN.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS
 NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED
 AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST
 OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE
 MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE
 ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN
 CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY
 SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE
 GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN
 ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM
 FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV)
 ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING
 FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 PLEASE MAKE A ITEMIZED LIST WHERE $25,000.00 DOLLARS OF
 ACCESSIBLE UPGRADES (20%) WILL BE MADE TO MAKE THE
 BUILDING ACCESSIBLE TO THE CURRENT 2010 ACCESSIBILITY
 CODE.
  
  
 5) 2ND REQUEST. NOTICE: CHAPTER 553.80(2)(B) FLORIDA
 STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A
 FEE OF FOUR TIMES THE FEE FOR
 PLAN REVIEW, IF PLANS ARE REJECTED OR MORE TIMES FOR
 REPEATED FAILURE TO CORRECT A CODE VIOLATION.
  
 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.. IF APPROVED SHOW APPROVED WITH A
 SHOP DRAWING STAMP, APPROVED OR APPROVED AS NOTED!
  
 6) NOTE AWNING SHOWN ON THE PLANS WILL BE REVIEWED
 UNDER A SEPARATE PERMIT.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-07-24 Cont ID  
Sent By jwitmer Date 2014-07-24 Time 07:51 Rev Time 0.00
Received By jwitmer Date 2014-07-24 Time 06:50 Sent To  
Notes
2014-07-24 07:49:39BUILDING PLAN REVIEW
 PERMIT: 14070650
 ADD: 1101 N TAMARIND AVE.
 CONT: FASTRACK CONSTRUCTION
 TEL: (561)772-8848
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. JULY 24/ 2014
 ACTION: DENIED
  
 1) SHEET A2 INDICATES A 2'-9" ACCESSIBLE RAMP WITH
 DETECTABLE WARNING ON THE RAMP. THE RAMP IS LACKING A
 TOP LANDING IN THE DIRECTION OF TRAVEL WITHOUT HAVING
 TO MAKE A 90 DEGREE TURN. PLEASE REVIEW THE FOLLOWING
 2010 FL ACCESSIBILITY CODE SECTIONS THAT DEAL WITH
 RAMPS.
 1A) 405.3 CROSS SLOPE. CROSS SLOPE OF RAMP RUNS SHALL
 NOT BE STEEPER THAN 1:48.
  
 1B) 405.4 FLOOR OR GROUND SURFACES. FLOOR OR GROUND
 SURFACES OF RAMP RUNS SHALL COMPLY WITH 302. CHANGES IN
 LEVEL OTHER THAN THE RUNNING SLOPE AND CROSS SLOPE ARE
 NOT PERMITTED ON RAMP RUNS.
  
 1C) 405.7 LANDINGS. RAMPS SHALL HAVE LANDINGS AT THE
 TOP AND THE BOTTOM OF EACH RAMP RUN. LANDINGS SHALL
 COMPLY WITH 405.7.
  
 1D) 05.7.3 LENGTH. THE LANDING CLEAR LENGTH SHALL BE 60
 INCHES (1525 MM) LONG MINIMUM.
  
 1E) 405.7.4 CHANGE IN DIRECTION. RAMPS THAT CHANGE
 DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR
 LANDING 60 INCHES (1525 MM) MINIMUM BY 60 INCHES (1525
 MM) MINIMUM.
  
 2) THE EXITING RESTROOM IS NOT CODE COMPLIANT TO THE
 2010 FL ACCESSIBILITY CODE, PLEASE REVIEW 2010 FL
 ACCESSIBILITY CODE 604.3.2.NOR DOES THE PLANS SHOW ANY
 ELEMENTS FOR A ACCESSIBLE RESTROOM.
  
 3) SUBMITTED PRODUCT APPROVAL FOR EXTERIOR DOORS IS NOA
 12-0706.03 PLEASE SHOW (CIRCLE) WHICH THRESHOLD WILL BE
 INSTALLED PAGE 2.1 OF 7 TO MAKE THE BUILDING CODE
 COMPLIANT WITH 2010 FL ACCESSIBILITY CODE 404.2.5.
  
 4) PLEASE REVIEW 2010 FL ACCESSIBILITY CODE, SECTIONS
 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE TO
 PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED
 AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL
 ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE
 ALTERATION TO THE PRIMARY FUNCTION AREA. COSTS THAT MAY
 BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN
 ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COSTS
 ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS
 ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS
 INSTALLING GRAB BARS, ENLARGING TOILET STALLS,
 INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET
 CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING
 ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE
 TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION
 DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV)
 COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE
 DRINKING FOUNTAIN.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS
 NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED
 AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST
 OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE
 MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE
 ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN
 CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY
 SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE
 GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN
 ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM
 FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV)
 ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING
 FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 PLEASE MAKE A ITEMIZED LIST WHERE $25,000.00 DOLLARS OF
 ACCESSIBLE UPGRADES (20%) WILL BE MADE TO MAKE THE
 BUILDING ACCESSIBLE TO THE CURRENT 2010 ACCESSIBILITY
 CODE.
  
  
 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 6) NOTE AWNING SHOWN ON THE PLANS WILL BE REVIEWED
 UNDER A SEPARATE PERMIT.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-09-08 Cont ID  
Sent By dhayes Date 2014-09-08 Time 09:02 Rev Time 0.00
Received By dhayes Date 2014-09-08 Time 09:02 Sent To  
Notes
2014-09-08 09:06:08DATE: 9/8/2014
 PROJECT: E & M LIQUORS
 PERMIT#: 14070650
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 2ND ELECTRICAL PLAN REVIEW
 ACTION: PROVISO
  
 SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY
 MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS
 FOR STORE FRONT SIGN.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-07-18 Cont ID  
Sent By dhayes Date 2014-07-18 Time 12:44 Rev Time 0.00
Received By dhayes Date 2014-07-18 Time 12:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2014-11-05 Cont ID  
Sent By pleduc Date 2014-11-05 Time   Rev Time 0.00
Received By pleduc Date 2014-11-05 Time 14:30 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-08-19 Cont ID  
Sent By pleduc Date 2014-08-19 Time   Rev Time 0.00
Received By pleduc Date 2014-08-19 Time 10:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-07-25 Cont ID  
Sent By pleduc Date 2014-07-25 Time   Rev Time 0.00
Received By pleduc Date 2014-07-25 Time 10:37 Sent To  
Notes
2014-07-25 12:13:57THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 ON SHEET A-2 IN THE FLOOR PLAN NOTES SECTION IT READS
 "ALL NEW DOORS SHALL BE IN FULL COMPLIANCE WITH THE
 PROVISIONS OF NFPA 101, 24.2.4". THAT SECTION OF THE
 CODE REFERS TO ONE AND TWO FAMILY DWELLINGS AND IS NOT
 APPLICCABLE TO THIS OCCUPANCY. A PROVISO HAS BEEN ADDED
 TO READ "37.2.2.2", REFERING TO MERCANTILE OCCUPANCY.
  
 ON SHEET A-2 IN THE FLOOR PLAN DRAWING, IT READS NEW
 IMPACT RATED DOOR WITH SECURITY SHUTTER ON INSIDE. THE
 SHUTTER SHALL NOT RESTRICT EGRESS AND COMPLY WITH NFPA
 101, CHAPTER 7. THE FIRE INSPECTOR SHALL CONFIRM
 COMPLIANCE ON FINAL INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-11-26 Cont ID  
Sent By hmoser Date 2014-11-26 Time 15:13 Rev Time 0.00
Received By hmoser Date 2014-11-04 Time 16:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-09-16 Cont ID  
Sent By aaponte Date 2014-09-16 Time 11:29 Rev Time 0.00
Received By aaponte Date 2014-08-14 Time 09:55 Sent To  
Notes
2014-09-16 11:30:00FAILED. UNDER "F" CONTRACTOR CONTACTED BY PHONE.
2014-08-15 09:55:15B26
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-08-15 Cont ID  
Sent By shill Date 2014-07-29 Time 09:55 Rev Time 0.00
Received By shill Date 2014-07-18 Time 12:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2014-11-26 Cont ID  
Sent By hmoser Date 2014-11-26 Time 15:13 Rev Time 0.00
Received By hmoser Date 2014-11-26 Time 15:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2014-08-18 Cont ID  
Sent By jdariton Date 2014-08-18 Time 09:49 Rev Time 0.00
Received By jdariton Date 2014-08-18 Time 09:52 Sent To  
Notes
2014-08-18 09:51:418/18/14 MUST ADDRESS THE PREVIOUS COMMENTS. JDA.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-07-29 Cont ID  
Sent By hmoser Date 2014-07-29 Time 10:07 Rev Time 0.00
Received By hmoser Date 2014-07-29 Time 09:03 Sent To  
Notes
2014-07-29 10:07:41PLAN DENIED
 PROVIDE DUCT AND GRILL SIZE ON NEW EXPOSED DUCT.
 PER SECTION 107 FBC 2010
 REFER TO SECTION 603.5 NONMETALLIC DUCT
 FYI DO NOT PAINT FIBERGLASS OR FLEX DUCT.
 2010 FBC (M) .
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 3 Status P Date 2014-11-19 Cont ID  
Sent By jwitmer Date 2014-11-19 Time 12:47 Rev Time 0.00
Received By jwitmer Date 2014-11-19 Time 12:47 Sent To  
Notes
2014-11-19 12:49:58NO PLUMBING WORK, EXISTING RESTROOM IS NOT ACCESSIBLE,
 THE CONTRACTOR USED UP THE 20 % DISPROPORTIONATE COST
 TO ACCESSIBLE ENTRANCE AND ACCESSABLE ALTERED WORK
 AREAS BEFORE BEFORE GETTING TO THE RESTROOMS.

Review Stop P PLUMBING
Rev No 2 Status F Date 2014-08-27 Cont ID  
Sent By jwitmer Date 2014-08-27 Time 06:31 Rev Time 0.00
Received By jwitmer Date 2014-08-27 Time 06:15 Sent To  
Notes
2014-08-27 06:29:04PLUMBING PLAN REVIEW
 PERMIT: 14070650
 ADD: 1101 N TAMARIND AVE.
 CONT: FASTRACK CONSTRUCTION
 TEL: (561)772-8848
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. AUG. 27/ 2014
 ACTION: DENIED
  
 RESPONSE INDICATES THERE IS A ITEMIZED LIST FROM THE
 CONTRACTOR IN THIS RESUBMITTAL, NO SUCH SUBMITTAL IN
 PACKAGE!!!!!!
  
 1 THE EXITING RESTROOM IS NOT CODE COMPLIANT TO THE
 2010 FL ACCESSIBILITY CODE, PLEASE REVIEW 2010 FL
 ACCESSIBILITY CODE 604.3.2.NOR DOES THE PLANS SHOW ANY
 ELEMENTS FOR A ACCESSIBLE RESTROOM.
  
 2)) PLEASE REVIEW 2010 FL ACCESSIBILITY CODE, SECTIONS
 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE TO
 PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED
 AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL
 ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE
 ALTERATION TO THE PRIMARY FUNCTION AREA. COSTS THAT MAY
 BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN
 ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COSTS
 ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS
 ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS
 INSTALLING GRAB BARS, ENLARGING TOILET STALLS,
 INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET
 CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING
 ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE
 TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION
 DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV)
 COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE
 DRINKING FOUNTAIN.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS
 NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED
 AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST
 OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE
 MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE
 ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN
 CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY
 SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE
 GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN
 ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM
 FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV)
 ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING
 FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 PLEASE MAKE A ITEMIZED LIST WHERE $25,000.00 DOLLARS OF
 ACCESSIBLE UPGRADES (20%) WILL BE MADE TO MAKE THE
 BUILDING ACCESSIBLE TO THE CURRENT 2010 ACCESSIBILITY
 CODE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-07-24 Cont ID  
Sent By jwitmer Date 2014-07-24 Time 07:49 Rev Time 0.00
Received By jwitmer Date 2014-07-24 Time 07:49 Sent To  
Notes
2014-07-24 07:51:07PLUMBING PLAN REVIEW
 PERMIT: 14070650
 ADD: 1101 N TAMARIND AVE.
 CONT: FASTRACK CONSTRUCTION
 TEL: (561)772-8848
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. JULY 24/ 2014
 ACTION: DENIED
  
 1 THE EXITING RESTROOM IS NOT CODE COMPLIANT TO THE
 2010 FL ACCESSIBILITY CODE, PLEASE REVIEW 2010 FL
 ACCESSIBILITY CODE 604.3.2.NOR DOES THE PLANS SHOW ANY
 ELEMENTS FOR A ACCESSIBLE RESTROOM.
  
 2)) PLEASE REVIEW 2010 FL ACCESSIBILITY CODE, SECTIONS
 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE TO
 PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED
 AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL
 ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE
 ALTERATION TO THE PRIMARY FUNCTION AREA. COSTS THAT MAY
 BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN
 ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COSTS
 ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS
 ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS
 INSTALLING GRAB BARS, ENLARGING TOILET STALLS,
 INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET
 CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING
 ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE
 TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION
 DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV)
 COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE
 DRINKING FOUNTAIN.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS
 NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED
 AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST
 OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE
 MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE
 ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN
 CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY
 SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE
 GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN
 ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM
 FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV)
 ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING
 FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 PLEASE MAKE A ITEMIZED LIST WHERE $25,000.00 DOLLARS OF
 ACCESSIBLE UPGRADES (20%) WILL BE MADE TO MAKE THE
 BUILDING ACCESSIBLE TO THE CURRENT 2010 ACCESSIBILITY
 CODE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2014-11-19 Cont ID  
Sent By jwitmer Date 2014-11-19 Time 12:46 Rev Time 0.00
Received By jwitmer Date 2014-11-19 Time 12:46 Sent To  
Notes
2014-11-19 12:47:33BUILDING PROVISO:
 ROOF REVIEW TO BE UNDER SEPARATE PERMIT,SUBMIT PRODUCT
 APPROVALS, TO BE REVIEWED BY THE DESIGNER OF RECORD
 BEFORE SUBMITANCE TO CITY FOR REVIEW. MINIMUM PERMIT
 FEE OF $80.00 SUB-PERMIT. JW

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2014-08-27 Cont ID  
Sent By jwitmer Date 2014-08-27 Time 07:09 Rev Time 0.00
Received By jwitmer Date 2014-08-27 Time 07:09 Sent To  
Notes
2014-08-27 07:09:49ROOFING PLAN REVIEW
 PERMIT: 14070650
 ADD: 1101 N TAMARIND AVE.
 CONT: FASTRACK CONSTRUCTION
 TEL: (561)772-8848
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. AUG. 27/ 2014
 ACTION: DENIED
  
 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 2) TWO (2) ROOFING REPORTS WERE SUBMITTED ONE FOR STEEL
 DECKS AND ONE FOR A CONCRETE DECK, PLEASE PROVIDE THE
 CORRECT REPORT, CIRCLE WHICH SUB-SYSTEM WHICH IS
 INTENDED TO BE INSTALLED. NOTE EACH SUB-SYSTEM HAS HAS
 LISTED A MAXIMUM DESIGN PRESSURE, SOME HAVE A
 LIMITATION #7 ( ENHANCED FASTENING) OTHER HAVE A
 LIMITATION # 9 (MAXIMUM DESIGN PRESSURE). IF ENHANCED
 FASTENING IS CHOSEN A ARCHITECT OR ENGINEER MUST
 PROVIDE THE RAS 117 CALCULATION FOR ZONES 2 & 3
 .2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.2.1.2 FOR
 ROOF ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION
 DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE
 TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING
 REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE
 RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT
 EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE
 WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE
 OR A STATEMENT BY AN ARCHITECT OR ENGINEER FOR THE
 SPECIFIC SITE MUST BE SUBMITTED WITH THE CONSTRUCTION
 DOCUMENTS.
  
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2014-07-24 Cont ID  
Sent By jwitmer Date 2014-07-24 Time 08:01 Rev Time 0.00
Received By jwitmer Date 2014-07-24 Time 07:53 Sent To  
Notes
2014-07-24 08:01:02ROOFING PLAN REVIEW
 PERMIT: 14070650
 ADD: 1101 N TAMARIND AVE.
 CONT: FASTRACK CONSTRUCTION
 TEL: (561)772-8848
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. JULY 24/ 2014
 ACTION: DENIED
  
 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 2) TWO (2) ROOFING REPORTS WERE SUBMITTED ONE FOR STEEL
 DECKS AND ONE FOR A CONCRETE DECK, PLEASE PROVIDE THE
 CORRECT REPORT, CIRCLE WHICH SUB-SYSTEM WHICH IS
 INTENDED TO BE INSTALLED. NOTE EACH SUB-SYSTEM HAS HAS
 LISTED A MAXIMUM DESIGN PRESSURE, SOME HAVE A
 LIMITATION #7 ( ENHANCED FASTENING) OTHER HAVE A
 LIMITATION # 9 (MAXIMUM DESIGN PRESSURE). IF ENHANCED
 FASTENING IS CHOSEN A ARCHITECT OR ENGINEER MUST
 PROVIDE THE RAS 117 CALCULATION FOR ZONES 2 & 3
 .2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.2.1.2 FOR
 ROOF ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION
 DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE
 TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING
 REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE
 RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT
 EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE
 WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE
 OR A STATEMENT BY AN ARCHITECT OR ENGINEER FOR THE
 SPECIFIC SITE MUST BE SUBMITTED WITH THE CONSTRUCTION
 DOCUMENTS.
  
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2014-11-21 Cont ID  
Sent By aaponte Date 2014-11-21 Time 14:26 Rev Time 0.00
Received By aaponte Date 2014-11-21 Time 14:26 Sent To  
Notes
2014-11-21 14:37:50PROVISO: 1. WHEEL STOP ON SOUTH PARKING SPACES SHALL BE
 MOVED 2 FEET INTO THE SPACE.
 2. PARKING STRIPING DETAIL SHALL FOLLOW CITY STANDARDS
 (SEC 94-485 STALL PAINTING DETAIL)
 3. PROVIDED SABAL PALMS SHALL BE SPACES ALONG THE WEST
 PROPERTY LINE.
 4. ANGLE PARKING SHALL MEET THE MINIMUM DIMENSION FOR A
 STALL DEPTH TO PROVIDE AT LEAST 22 FEET DRIVE AISLE.
 4. A SEPARATE LANDSCAPE AND IRRIGATION PERMIT IS
 REQUIRED.

Review Stop Z ZONING
Rev No 2 Status F Date 2014-09-16 Cont ID  
Sent By aaponte Date 2014-09-16 Time 10:06 Rev Time 0.00
Received By aaponte Date 2014-09-16 Time 10:06 Sent To  
Notes
2014-09-16 11:28:091. ACCORDING TO THE PAPA WEBSITE, THE IMPROVEMENT VALUE
 OF THE PROPERTY IS $34,000, AND THE LISTED VALUE OF THE
 PROPOSED IMPROVEMENTS IS $125,000, EXCEEDING 50% OF THE
 IMPROVEMENT VALUE. THE LANDSCAPE AND PARKING SHALL BE
 UPGRADED TO MEET CODE.
 2. LANDSCAPE BUFFER ALONG TAMARIND SHALL BE 10 FEET IN
 WIDTH, AND A SHADE TREE SHALL BE PLANTED ON EACH SIDE
 OF PARKING ENTRANCE.
 3. SHADE TREE SHALL BE PLANTED EVERY 30 FEET ALONG THE
 ENTIRE PERIMETER OF THE PARKING AREA. A HEDGE IS
 REQUIRED ALONG THE ENTIRE PERIMETER OF THE PARKING LOT.
 4. ALL LANDSCAPE AREAS SHALL BE PROTECTED BY A WHEEL
 STOP OR A CURB.
 5. SURVEY SHALL BE SIGNED AND SEALED AND AT SCALE.
 6. CURRENTLY THERE IS A DUMPSTER ON THE SITE NOT SHOWN
 IN THE DRAWINGS. DUMPSTER SHALL BE ENCLOSED AND
 SCREENED WITH AN OPAQUE FENCE OR WALL. A HEDGE SHALL BE
 PROVIDED ALONG THE FENCE OR WALL. PLEASE COORDINATE
 WITH THE SANITATION DEPARTMENT TO ENSURE THE CURRENT
 LOCATION OF THE DUMPSTER IS THE OPTIMAL PICK UP
 LOCATION. (FERDINAND RIVERA 822-2076).
 7. STRIPING DETAIL DOES NOT REFLECT THE CITY'S STANDARD
 (SEC 94-485), PLEASE UPDATE.
 8. PARKING SPACES CAN BE REDUCED TO THE MINIMUM
 REQUIRED ACCORDING TO FIGURE XV-2 IN SECTION 94-485 OF
 THE ZONING CODE TO INCREASE THE LANDSCAPE AREAS.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.
2014-08-26 13:39:288/25/14

Review Stop Z ZONING
Rev No 1 Status F Date 2014-07-29 Cont ID  
Sent By aaponte Date 2014-07-29 Time 14:11 Rev Time 0.00
Received By aaponte Date 2014-07-29 Time 14:11 Sent To  
Notes
2014-07-29 14:28:571. NEW LANDSCAPE SHALL BE INSTALLED AROUND THE SURFACE
 PARKING LOT TO COMPLY WITH CURRENT REQUIREMENTS. SEE
 SEC 94-113(F) OF THE ZONING CODE.
 2. ALL LANDSCAPED AREAS SHALL BE PROTECTED BY A CURB OR
 A WHEEL STOP.
 3. PLEASE REVISE PARKING STALL DETAIL TO COMPLY WITH
 CITY REQUIREMENTS (SEC 94-485).
 4. PLEASE SUBMIT A SURVEY OF THE PROPERTY.
 5. PLEASE INCLUDE ALL PARKING DIMENSIONS ON SITE PLAN.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.
2014-07-29 10:52:237/29/14 ZONING SENT TO AA. SG
2014-07-25 10:34:467/25/14