Plan Review Details - Permit 14070406
Plan Review Stops For Permit 14070406
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-08-28 Cont ID  
Sent By jwitmer Date 2014-08-28 Time 06:31 Rev Time 0.00
Received By jwitmer Date 2014-08-28 Time 05:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-07-23 Cont ID  
Sent By jwitmer Date 2014-07-23 Time 16:21 Rev Time 0.00
Received By jwitmer Date 2014-07-23 Time 12:04 Sent To  
Notes
2014-07-23 16:21:37PLANS WILL BE STAMPED NEXT REVIEW CYCLE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-08-07 Cont ID  
Sent By rlecky Date 2014-08-07 Time 12:45 Rev Time 0.00
Received By rlecky Date 2014-08-07 Time 10:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-07-15 Cont ID  
Sent By pleduc Date 2014-07-15 Time   Rev Time 0.00
Received By pleduc Date 2014-07-15 Time 15:19 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2014-08-28 Cont ID  
Sent By jwitmer Date 2014-08-28 Time 06:31 Rev Time 0.00
Received By jwitmer Date 2014-08-28 Time 05:35 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2014-07-23 Cont ID  
Sent By jwitmer Date 2014-07-23 Time 16:13 Rev Time 0.00
Received By jwitmer Date 2014-07-23 Time 15:30 Sent To  
Notes
2014-07-23 16:13:23FUEL GAS PLAN REVIEW
 PERMIT: 14070406
 ADD:101 N CLEMATIS ST SUITES 120 & 130
 CONT: CHANDLER
 TEL: (561)791-6934
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED JULY 23/ 2014
 ACTION: DENIED
  
 1) SHEET P02 & P2.3 SHOW SOME GAS DETAILS, SHEET P3.1
 DETAIL # 4 SHOW A 120 GALLON GAS WATER HEATER. THE
 DETAIL SHOWS WHAT APPEARS TO BE A ONE STORY BUILDING,
 PLEASE NOTE THIS IS A 5 STORY BUILDING WITH RESIDENTIAL
 UNITS ABOVE. PLEASE PROVIDE COMPLIANCE WITH THE
 FOLLOWING:
  
 1A) SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE
 AND TERMINATION OF THE GAS VENTS PER FBC-2010 FUEL GAS
 CODE SEC. 502 THRU 505.
  
 1B) SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO
 VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2010 FUEL GAS SEC. 402.2
  
 1C) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2010 FUEL GAS CODE SEC. 304
  
 2) THE PLANS ALSO INDICATE (2) GAS DRIERS SHOW
 COMPLIANCE WITH:
  
 2A) SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE
 AND TERMINATION OF THE GAS VENTS PER FBC-2010 FUEL GAS
 CODE SEC. 502 THRU 505.
  
 2B) SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO
 VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2010 FUEL GAS SEC. 402.2
  
 2C) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2010 FUEL GAS CODE SEC. 304.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-08-28 Cont ID  
Sent By jwitmer Date 2014-08-28 Time 06:32 Rev Time 0.00
Received By jwitmer Date 2014-08-26 Time 10:46 Sent To  
Notes
2014-08-27 10:46:31TO JW DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-08-13 Cont ID  
Sent By hmoser Date 2014-08-13 Time 09:12 Rev Time 0.00
Received By hmoser Date 2014-07-11 Time 13:09 Sent To  
Notes
2014-07-14 13:10:29SENT TO B28 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-08-13 Cont ID  
Sent By hmoser Date 2014-08-13 Time 09:12 Rev Time 0.00
Received By hmoser Date 2014-08-12 Time 14:19 Sent To  
Notes
2014-08-13 09:12:17PASS PROVISO
  
 REFER TO SECTION 503.2.4.4 SHUT OFF DAMPER CONTROLS.
 2010 FLORIDA ENERGY CODE .
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-08-28 Cont ID  
Sent By jwitmer Date 2014-08-28 Time 06:31 Rev Time 0.00
Received By jwitmer Date 2014-08-28 Time 05:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-07-23 Cont ID  
Sent By jwitmer Date 2014-07-23 Time 16:20 Rev Time 0.00
Received By jwitmer Date 2014-07-23 Time 12:04 Sent To  
Notes
2014-07-23 16:20:51PLUMBING PLAN REVIEW
 PERMIT: 14070406
 ADD:101 N CLEMATIS ST SUITES 120 & 130
 CONT: CHANDLER
 TEL: (561)791-6934
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED JULY 23/ 2014
 ACTION: DENIED
  
 1) SHEET P3.1 DETAIL # 6 SHOWS A/C CONDENSATE BEING
 DRAINED INTO A SANITARY DRAIN WITH A SINK TAIL PIECE
 ADAPTOR FOR A DISHWASHER WASTE.
 PLEASE PROVIDE COMPLIANCE WITH:
 2010 FBC-PLUMBING 314.2.1 CONDENSATE DISPOSAL.
 CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL
 BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED
 PLACE OF DISPOSAL. SUCH PIPING SHALL MAINTAIN A MINIMUM
 HORIZONTAL SLOPE IN THE DIRECTION OF DISCHARGE OF NOT
 LESS THAN ONE-EIGHTH UNIT VERTICAL IN 12 UNITS
 HORIZONTAL (1-PERCENT SLOPE). CONDENSATE SHALL NOT
 DISCHARGE INTO A STREET, ALLEY OR OTHER AREAS SO AS TO
 CAUSE A NUISANCE. AN APPROVED PLACE OF DISPOSAL IS ROOF
 DRAINS, FRENCH DRAINS, ETC...
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status N Date 2014-08-28 Cont ID  
Sent By aaponte Date 2014-08-28 Time 06:32 Rev Time 0.00
Received By jwitmer Date 2014-08-28 Time 06:32 Sent To  
Notes
2014-07-25 10:16:347/25/14


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved