Plan Review Stops For Permit 14061326 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2015-08-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-08-14 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-08-14 |
Time |
14:41 |
Sent To |
|
|
Notes |
2015-08-14 14:54:11 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- REVISE "METAL HANDRAIL DETAIL ON SHEET A-2 TO MATCH | | FLOOR PLAN AND FRONT ELEVATION. IS THERE A HANDRAIL AND | | GUARDRAIL?. REVISE SIZE OF METAL FRAMING MEMBERS 1-1/2 | | AND 2"?. SPECIFY CONNECTIONS TO CONCRETE STEP AND TO | | COLUMN. | | 2- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR | | CONSTRUCTION OF STEPS AND SPECIFY RISER AND TREAD TO | | SHOW COMPLIANCE WITH SEC. R311.7.4. | | 3- REVISE WALL SECTION A/A-2: SCREEN VENTS AT 24" O.C. | | DON'T PROVIDE CROSS VENTILATION. | | 4- SHEET A2: | | A) REVISE PORCH SECTION: (1) SPECIFICATIONS CALL FOR | | (3)2X10 WD BEAM. ONLY 2 ARE SHOWN. | | (2) ROOF RAFTERS ARE 2X6. ROOF FRAMING CALLS FOR 2X8. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2015-07-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-07-06 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-07-06 |
Time |
15:20 |
Sent To |
|
|
Notes |
2015-07-06 15:21:53 | RESIDENTIAL (R3) ALTERATION/ ADDITION FIFTH BUILDING | | REVIEW CHECKLIST. | | CODE: 2010 FBC. | | | | NOTE: THESE COMMENTS APPLY TO FRONT AND REAR BUILDINGS. | | DRAWINGS A-1 TO A-5 SUBMITTED ARE FOR BOTH STRUCTURES: | | | | 1-VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN | | PROFESSIONAL FEES FEES. PROVIDE COPY OF SIGNED CONTRACT | | THAT DESCRIBES ALL THE SCOPE OF WORK. SEC. 109.3 CITY | | AMENDMENTS. (REPEAT COMMENT. NOT ADDRESSED. PROVIDE | | BREAKDOWN FOR THE SCOPE OF WORK ON MAIN HOUSE AND SCOPE | | OF WORK ON REAR STRUCTURE). | | | | 2- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS | | FOR THE INSTALLATION OF THE NEW ATTIC ACCESS WITH | | LADDER. (REPEAT COMMENT. NOT ADDRESSED. ROOF FRAMING | | DETAILS NOT PROVIDED. ) | | | | 3- PROVIDE GARAGE DOOR COMPLETE FRAMING DETAILS AND | | SPECIFICATIONS. SPECIFY ALL FRAMING MEMBERS AND | | FASTENERS. SEC. R301.1 OF 2010 FBC-RESIDENTIAL. (REPEAT | | COMMENT). | | | | 4- PROVIDE STAIRS, HANDRAILS AND GUARDRAIL THAT MATCHES | | NEW PORCH. PROVIDE COMPLETE FRAMING DETAILS AND | | SPECIFICATIONS SHOWING COMPLIANCE WITH THE LIVE LOADS | | OF TABLE R301.5 OF 2010 FBC-RESIDENTIAL. SPECIFY ALL | | FRAMING MEMBERS AND FASTENERS. (REPEAT COMMENT. THE | | FRONT ELEVATION IS NOW MISSING THE GUARDRAILS. THERE IS | | NOTHING TO COMPARE TO PROPOSED GUARDRAIL. HANDRAIL | | DETAIL SUBMITTED SEEMS TO BE FOR INTERIOR HANDRAIL. AND | | CLARIFY HOW ARE THE #12X3" WD. SCREWS TOP & BTM. @16" | | O/C INSTALLED AS SHOWN ON THE HANDRAIL DETAIL?. FLOOR | | PLAN ON SHEET A-1 CALLS FOR ALUMINUM RAILING. THIS | | DETAIL IS FOR WOOD RAILING. SEC. 107.2.1 CITY | | AMENDMENTS). | | | | 5- WALL SECTION A/A-2: PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW PROVIDING "CROSS | | VENTILATION" SEC. R806 OF 2010 FBC-RESIDENTIAL. (REPEAT | | COMMENT. SPECIFY SPACING OF THE 4"X7" SPECIFIED VENTS | | TO VERIFY CROSS VENTILATION.). | | | | 6- REVISE DOOR STRUCTURAL BUCK DETAIL. REVISE SIZE AND | | REVISE DETAIL TO SHOW FULL SUPPORT TO THE DOOR FRAME AS | | REQUIRED BY SEC. R612.10.2.1 OF 2010 FBC-RESIDENTIAL. | | (REPEAT COMMENT. NOT ADDRESSED. 2X4 BUCK DOESN'T | | PROVIDE FULL SUPPORT TO THE DOOR FRAME). | | | | 7- CLARIFY WHERE IS THE GAF MINERAL GUARD RESIDENTIAL | | ROLL ROOFING UNDERLAYMENT (NOA 13-1104.03) SUBMITTED | | GOING TO BE INSTALLED? SEC. 107.2.1 CITY AMENDMENTS. | | | | 8- CLARIFY WHERE IS THE GAF CONVENTIONAL BUILT-UP ROOF | | SYSTEM (NOA 13-1022.15) SUBMITTED GOING TO BE | | INSTALLED?. SEC. 107.2.1 CITY AMENDMENTS. PLANS CALL | | FOR EXISTING FLAT ROOF ON REAR BUILDING. NO RE-ROOF. IF | | THIS BUILDING IS GOING TO BE RE-ROOFED, THEN NEED TO | | IDENTIFY SPECIFIC ASSEMBLY TO BE INSTALLED AND PROVIDE | | SIGNED AND SEALED RAS 117 CALCULATIONS AS REQUIRED BY | | GENERAL LIMITATION #7 ON LAST PAGE OF THE NOA. | | | | 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: | | A) ROOF SHINGLES. (REPEAT COMMENT. NO PRODUCT APPROVAL | | SUBMITTED). | | | | B) SINGLE HUNG WINDOW. INFORMATION SUBMITTED DOESN'T | | HAVE A FLORIDA PRODUCT APPROVAL NUMBER. PROVIDE THE | | CORRESPONDING FLORIDA PRODUCT APPROVAL FOR THE | | SUBMITTED PACKAGE OR MANUFACTURER MAY APPLY FOR LOCAL | | PRODUCT APPROVAL (COMPLETE ENGINEERING PACKAGE WILL BE | | REQUIRED FOR BUILDING OFFICIAL APPROVAL). | | | | C) ALL SIMPSON STRUCTURAL CONNECTORS AND USP STRUCTURAL | | CONNECTORS SPECIFIED ON FRAMING PLANS AND ALL DETAILS. | | OR SPECIFY THE FLORIDA PRODUCT APPROVAL NEXT TO THE | | SPECIFIED CONNECTOR. (REPEAT COMMENT). | | | | 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ALL PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 11- SHEET A-1: | | A) LETTERING ON THE SITE PLAN IS NOT LEGIBLE. SEC | | 107.2.1.4 CITY AMENDMENTS. | | | | B) MAIN SCOPE ON MAIN NOTES SPECIFY "FIRE DAMAGE | | REPAIRS". PLANS DON'T SHOW ANY INFORMATION REGARDING | | THIS. PROVIDE COMPLETE DETAILS AND SPECIFICATIONS | | SHOWING AREAS DAMAGED BY FIRE AND PROPOSED REPAIRS. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | 12- SHEET A2: | | A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | CONSTRUCTION OF NEW PORCH STEPS SHOWING COMPLIANCE WITH | | SEC. R311.7.4 OF 2010 FBC-RESIDENTIAL. | | | | B) LETTERING ON SIMPSON STRAPS AND POST/CAPS SCHEDULES | | IS NOT LEGIBLE. IT'S TOO SMALL. SEC.107.2.1.4 CITY | | AMENDMENTS. | | | | C) CLEARLY COORDINATE INFORMATION SHOWN ON THE SIMPSON | | STRAPS AND POST/CAPS SCHEDULES, ROOF FRAMING PLAN, | | PORCH SECTION AND DETAILS B/A2, C/A2 AND D/A2. THIS IS | | LIKE CUTTING AND PASTING INFORMATION BUT IT DOESN'T | | MATCH ACTUAL CONDITIONS. CHECK SIZES OF FRAMING | | MEMBERS, ACTUAL CONNECTIONS, CONNECTORS SIZES VS | | STRUCTURAL MEMBERS, ETC. SEC. 107.2.1 CITY AMENDMENTS. | | | | D) PORCH SECTION: (1) CLARIFY FINISH GRADE LEVEL. 16" | | OR 24'. SEE FRONT ELEVATION. CLARIFY NEW CONCRETE PORCH | | SLAB CONSTRUCTION. PORCH SECTION SHOWS CRAWL SPACE | | BELOW THE SLAB. NEED TO PROVIDE COMPLETE INFORMATION | | FOR UNDER FLOOR SPACE AS REQUIRED BY SEC. R408 OF 2010 | | FBC-RESIDENTIAL. AND, NEED TO SHOW HOW IS THE SLAB | | ANCHORED TO THE EXITING WALL. SEC. 107.2.1 CITY | | AMENDMENTS. (2) SPECIFICATIONS CALL FOR (3)2X10 WD | | BEAM. ONLY 2 ARE SHOWN. (3) ROOF RAFTERS ARE 2X6. ROOF | | FRAMING CALLS FOR 2X8. (4) | | | | 13- SHEET A-5: | | A) NEW FLOOR PLAN CALLS WINDOW ON THE LEFT HAND SIDE AS | | "EXISTING WINDOW". PLANS ARE MISLEADING BECAUSE | | ACCORDING TO THE DEMOLITION PLAN THIS WINDOW IS NOT | | PLACED IN THE SAME LOCATION. CLEARLY SPECIFY IF THE | | WINDOW WAS REMOVED. IF IT WAS REMOVED, THEN THE SAME | | WINDOW CAN'T BE USED UNLESS PRODUCT APPROVAL FOR THE | | SAME WINDOW IS PROVIDED. SEC. 107.2.1 CITY AMENDMENTS. | | | | 14- SHEET A4: THERE IS A NEW BILLIARD ROOM SHOWN ON THE | | FLOOR PLAN. THE ROOM SEEMS TO BE TOO SMALL FOR A | | BILLIARD ROOM. PROVIDE COMPLETE LAYOUT OF POOL TABLE | | SHOWING CLEARANCES TO PLAY POOL. NOTE: ORIGINALLY, THIS | | ROOM WAS DESIGNED AS A BEDROOM. PROVIDE CLARIFICATION | | WHY CHANGING THE BEDROOM FOR A BILLIARD ROOM THAT MAY | | NOT BE SUITABLE BECAUSE THERE IS NOT ENOUGH ROOM. THE | | PROPOSED USE OF THIS ROOM MAY NOT BE SUITABLE BASED ON | | THE SIZE OF ROOM. SEC. 102.2CITY AMENDMENTS. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2015-04-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-04-13 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-04-13 |
Time |
17:26 |
Sent To |
|
|
Notes |
2015-04-13 17:26:48 | RESIDENTIAL (R3) ALTERATION/ ADDITION FOURTH BUILDING | | REVIEW CHECKLIST. | | CODE: 2010 FBC. | | | | NOTE: THESE COMMENTS APPLY TO FRONT AND REAR BUILDINGS. | | DRAWINGS A-1 TO A-5 SUBMITTED: | | | | 1- SITE PLAN SHOWN ON SHEET A-1 DOESN'T MATCH SITE PLAN | | SHOWN ON SHEET A-5. AND IS MISSING THE CONNECTION | | (LAUNDRY ROOM) OF THE GARAGE WITH THE REAR BUILDING. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | 2- SCOPE OF WORK SPECIFIED ON SHEET A-1 DOESN'T MATCH | | SCOPE OF WORK SPECIFIED ON SHEET A-5. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 3- DESIGN DATA FOR WIND LOADS SHOWN ON SHEET A-1 | | DOESN'T MATCH DESIGN DATA SPECIFIED ON SHEET A-5. SEC. | | 107.2.1 CITY AMENDMENTS. | | | | 4- INFORMATION SHOWN ON THE DESIGN DATA ON SHEET A-1 | | AND SHEET A-5 IS CONFUSING. INFORMATION FOR INTERIOR | | AND END ZONE IS REPEATED TWICE BUT THE DESIGN PRESSURES | | ARE DIFFERENT. REVISE AS REQUIRED. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | PROFESSIONAL FEES FEES. PROVIDE COPY OF SIGNED CONTRACT | | THAT DESCRIBES ALL THE SCOPE OF WORK. SEC. 109.3 CITY | | AMENDMENTS. | | | | 6- SHEET A-1: | | A) PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS | | FOR THE INSTALLATION OF THE NEW ATTIC ACCESS WITH | | LADDER. | | | | B) ENGINEER OF RECORD TO SPECIFY THE ALTERATION LEVEL | | TYPE OR COMBINATION OF LEVELS OF ALTERATION AS REQUIRED | | BY SEC. 401.4 OF 2010 FBC-EXISTING BUILDING. | | | | C) CLEARLY SPECIFY WHICH WINDOWS AND EXTERIOR DOORS ARE | | EXISTING AND WHICH ARE GOING TO BE REPLACED. IF | | REPLACING EXISTING BEDROOM WINDOWS, THEN SPECIFY | | EXISTING TYPE AND SIZE AND PROPOSED TYPE AND SIZE TO | | VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. | | 604 OF 2010 FBC-EXISTING BUILDING. | | | | 7- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. | | | | 8- COORDINATE LABELING NUMBERS OF BUILDINGS SHOWN ON | | THE SITE PLAN WITH LABELING OF BUILDINGS SHOWN ON | | SHEETS A-2 TO A-5. REVISE AS REQUIRED. CLEARLY MATCH | | BUILDING #1, BUILDING #2 AND BUILDING #3 WITH NUMBERS | | SHOWN ON THE SITE PLAN. SEC. 107.2.1 CITY AMENDMENTS. | | | | 9- SHEET A-2: | | A) PROVIDE GARAGE DOOR COMPLETE FRAMING DETAILS AND | | SPECIFICATIONS. SEC. R301.1 OF 2010 FBC-RESIDENTIAL. | | | | B) PROVIDE STAIRS, HANDRAILS AND GUARDRAIL THAT MATCHES | | NEW PORCH ON SHEET A-5. PROVIDE COMPLETE FRAMING | | DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE WITH THE | | LIVE LOADS OF TABLE R301.5 OF 2010 FBC-RESIDENTIAL. | | SPECIFY ALL FRAMING MEMBERS AND FASTENERS. | | | | C) INFORMATION SHOWN ON THE WOOD FRAMING DETAIL | | SECTION, WALL SECTION AND DOOR FRAMING SECTION DOESN'T | | MATCH. REVISE AS REQUIRED TO MATCH AND CLARIFY WHERE | | ARE THESE SECTIONS TAKEN AT. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 10- SHEET A-3: | | A) WALL SECTION A/A-1: PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW PROVIDING "CROSS VENTILATION | | IN BLOCKING" AS SPECIFIED ON THE WALL SECTION. SEC. | | R806 OF 2010 FBC-RESIDENTIAL. | | | | B) REVISE DOOR STRUCTURAL BUCK DETAIL. REVISE SIZE AND | | REVISE DETAIL TO SHOW FULL SUPPORT TO THE DOOR FRAME AS | | REQUIRED BY SEC. R612.10.2.1 OF 2010 FBC-RESIDENTIAL. | | | | C) SIZE OF WINDOW SHOWN ON THE LEFT ELEVATION DOESN'T | | MATCH SIZE SPECIFIED ON THE FLOOR PLAN. REVISE AS | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | D) REVISE WINDOWS AND DOORS DESIGN PRESSURES TO MATCH | | CORRECT DESIGN PRESSURES AS SPECIFIED ON SHEET A-1 AND | | A-5. SEC. R301.1 OF 2010 FBC-RESIDENTIAL. | | | | E) RIGHT ELEVATION DOESN'T MATCH FLOOR PLAN. SEC. | | 107.2.1 CITY AMENDMENTS. | | | | 11- SHEET A-4: | | A) CLEARLY SPECIFY EXISTING AND PROPOSED WINDOWS AND | | EXTERIOR DOORS. (COORDINATE WITH EXTERIOR ELEVATIONS ON | | SHEET A-3). SEC. 107.2.1 CITY AMENDMENTS. | | | | B) NEW FLOOR PLAN SHOWS "NEW BILLIARD ROOM" AND "NEW | | PLAYROOM". PREVIOUS PLANS SHOWED THESE ROOMS AS | | BEDROOMS. IT'S NOT CLEAR WHY THE ROOMS WERE REDESIGNED | | AS PLAYROOMS, BUT IF THE ROOMS ARE NOT DESIGNED AS | | BEDROOMS, THEN ENGINEER OF RECORD TO SPECIFY ON PLANS | | THAT THESE ROOMS CAN NOT BE USED FOR SLEEPING PURPOSES. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | 12- SHEET A-5: | | A) THIS IS NOT ALTERATION LEVEL 2. REVISE AS REQUIRED. | | SEE SEC.401.4 OF 2010 FBC-EXISTING BUILDING. | | | | B) ROOF FRAMING PLAN IS MISSING INFORMATION: (1) | | PROVIDE WALL SECTION SHOWING WHERE IS THE NEW 2X8 WOOD | | LEDGER GOING TO BE ATTACHED TO THE EXISTING BUILDING. | | (2) SPECIFY LEDGER ANCHOR BOLT SIZE AND SPACING. (3) | | SPECIFY CEILING CLEARANCES. (4) SPECIFY BEAM SIZE. (5) | | SPECIFY ROOF PITCH. (6) SPECIFY ROOF SHEATHING SIZE AND | | FASTENER TYPE AND SPACING. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 13- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: | | A) EXTERIOR DOORS AS SHOWN ON PLANS. | | | | B) ROOF SHINGLES. NOA 11-0913.10 SUBMITTED WAS THE | | APPROVAL FOR ANOTHER PROJECT AND WAS REVIEWED AND | | APPROVED BY ANOTHER ENGINEER NOT THE ONE RESPONSIBLE | | FOR THIS PROJECT. AND NEED 2 COPIES. ONLY 1 WAS | | SUBMITTED. | | | | C) OVERHEAD GARAGE DOOR. NEED PRODUCT APPROVAL FOR SIZE | | OF GARAGE DOOR SPECIFIED ON PLANS. ALSO, NOA 12-0125.20 | | SUBMITTED IS FOR ANOTHER PERMIT AND WAS APPROVED BY | | ANOTHER ENGINEER NOT THE ONE RESPONSIBLE FO THIS | | PROJECT. | | | | D) SINGLE HUNG WINDOW. NOA 11-1013.14 SUBMITTED IS NOT | | LEGIBLE. | | | | E) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | FRAMING PLANS AND ALL DETAILS. OR SPECIFY THE FLORIDA | | PRODUCT APPROVAL NEXT TO THE SPECIFIED CONNECTOR. | | FLORIDA PRODUCT APPROVAL WAS SUBMITTED FOR SOME | | CONNECTORS, BUT NOT ALL OF THEM. | | | | 14- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ALL PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. | | NOTE: ENGINEER TO CLARIFY WHY THE SIGNATURE ON THE | | APPROVED PRODUCT APPROVALS IS DIFFERENT THAT THE | | SIGNATURE ON THE PLANS. PROVIDE SIGNED AND SEALED | | LETTER WITH EXPLANATION. CHAPTER 471 F.S. | | | | 15- ENGINEER IS USING OLD SEAL. NEED TO USE CURRENT | | SEAL WITH THE WORDING "LICENSE" NOT "CERTIFICATE". SEC. | | 61G15-23.001. F.A.C. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2014-11-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-07 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-07 |
Time |
07:29 |
Sent To |
|
|
Notes |
2014-11-07 07:30:20 | RESIDENTIAL (R3) ALTERATION THIRD BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | ***NOTE: THESE COMMENTS APPLY TO FRONT BUILDING ONLY. | | REAR BUILDING COMMENTS ARE UNDER PERMIT #14061324. | | | | 1- SCOPE OF WORK IS NOT CLEAR. SCOPE OF WORK SPECIFIED | | ON SHEET A-1 DOESN'T REFLECT WHAT THE FLOOR PLANS SHOW | | AND WHAT THE PERMIT APPLICATION SPECIFIES. REVISE ALL L | | THE INFORMATION AS REQUIRED TO MATCH. SEC. 107.2.1 CITY | | AMENDMENTS TO FBC. | | | | 2- REVISE VALUATION ON THE PERMIT APPLICATION TO MATCH | | ALL THE SCOPE OF WORK SPECIFIED IN THE REVISED | | INFORMATION REQUESTED ON ITEM #1 ABOVE. SEC. 109.3 CITY | | AMENDMENTS TO FBC. | | | | 3- ENGINEER TO PROVIDE COMPLETE INFORMATION FOR THE NEW | | STAIRS AT THE BOTTOM RIGHT SIDE SHOWN ON THE ELECTRICAL | | PLAN. PROVIDE COMPLETE FRAMING DETAILS AND | | SPECIFICATIONS FOR NEW DOOR, INCLUDING SIZE. PROVIDE | | COMPLETE DETAILS AND SPECIFICATIONS FOR THE NEW STAIRS | | SHOWING COMPLIANCE WITH SEC. R311.3 OF 2010 FBC- | | RESIDENTIAL. INCLUDE THE REQUIRED LANDING AND RISER AND | | TREADS DIMENSIONS. | | | | 4- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: | | A) ANY NEW DOORS OR EXTERIOR DOORS TO BE REPLACED. | | B) ANY NEW WINDOWS OR WINDOWS TO BE REPLACED. | | C) ALL STRUCTURAL CONNECTORS SPECIFIED ON THE FRAMING | | DETAILS. PROVIDE ONLY THE PRODUCT APPROVAL COVER PAGE | | AND PAGE SHOWING THE SPECIFIED CONNECTOR. | | D) WINDOW MULLIONS, IF USED. | | E) ROOF SHINGLES IF THIS SCOPE OF WORK IS GOING TO BE | | INCLUDED. | | | | ***NOTE: THERE WERE SOME PRODUCT APPROVALS THAT WERE | | INLCUDED IN THIS PACKAGE. THEY HAD A DIFFERENT PERMIT | | NUMBER STAMPED ON THE FRONT COVER. THEY WERE ROUTED TO | | R12 SHELF TO RIDE ALONG WITH THAT PERMIT APPLICATION. | | | | 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ALL PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS | | TO FBC. | | | | 6- IF REPLACING BEDROOM WINDOWS, THEN SPECIFY EXISTING | | WINDOW TYPE AND SIZE AND PROPOSED WINDOW TYPE AND SIZE | | TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENT OF | | SEC. 604 OF 2010 FBC-EXISTING BUILDING. | | | | 7- IF REPLACING DOOR AND WINDOWS, THEN CLEARLY IDENTIFY | | ON PLANS WHICH DOORS AND WINDOWS ARE GOING TO BE | | REPLACED. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | ***PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected]. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-10-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-10-15 |
Time |
17:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-10-15 |
Time |
17:55 |
Sent To |
|
|
Notes |
2014-10-15 17:55:39 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | ***NOTE: | | FLOOR PLANS AND INFORMATION SUBMITTED IS FOR 635 37TH | | STREET. THIS IS THE INCORRECT ADDRESS FOR THIS PERMIT | | APPLICATION. NEED TO PROVIDE COMPLETE INFORMATION | | ADDRESSING THE ORIGINAL COMMENTS BELOW: | | | | | | | | 1- NO PLANS WERE SUBMITTED SHOWING SCOPE OF WORK. | | PROVIDE COMPLETE INFORMATION FOR REVIEW. SEC. 107.2.1 | | CITY AMENDMENTS TO FBC. ***NOTE: COORDINATE WITH ITEM | | #2 BELOW. | | | | 2- IT LOOKS LIKE THIS PERMIT WAS APPLIED FOR TO REVOKE | | EXPIRED PERMIT APPLICATION #10110532. PERMIT | | APPLICATION #10110532 WAS NEVER APPROVED BECAUSE | | COMMENTS WERE NEVER ADDRESSED. PLEASE REVISE SCOPE OF | | WORK TO MATCH SCOPE OF WORK SUBMITTED ON PERMIT | | APPLICATION #10110532. THE FOLLOWING IS THE SCOPE OF | | WORK FOR PERMIT APPLICATION #10110532: "MAIN HOUSE - | | RENOVATION / REPAIRS. ELECTRIC, SHEETROCK, STUCCO, | | CLOSE 2 WINDOWS & 1 DOOR WITH LATHE/STUCCO. INSTALL NEW | | DOOR ON NORTH SIDE & REAR DOOR. ROOF SHINGLES, HVAC AIR | | HANDLER & COMPRESSOR". SEC. 107.2.1 CITY AMENDMENTS TO | | FBC. | | | | 3- REVISE VALUATION TO REFLECT ALL THE SCOPE OF WORK. | | VALUATION TO INCLUDE ALL LABOR AND MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | PROFESSIONAL FEES. SEC. 109.3 CITY AMENDMENTS TO FBC. | | | | 4- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: ALL WINDOW TYPES TO BE REPLACED, | | WINDOW MULLIONS TO BE REPLACED, ALL EXTERIOR DOORS, | | ROOF SHINGLES, | | | | 5- PROVIDE SOME SORT OF KEY PLAN IDENTIFYING ALL | | WINDOWS AND DOORS TO BE REPLACED. CLEARLY SPECIFY TYPE | | AND SIZE OF ALL EXISTING BEDROOM WINDOWS TO BE REPLACED | | AND PROPOSED WINDOW TO BE INSTALLED TO VERIFY | | COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. 604 OF | | 2010 FBC-EXISTING BUILDING. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-07-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-07-29 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-07-29 |
Time |
09:49 |
Sent To |
|
|
Notes |
2014-07-29 09:59:16 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- NO PLANS WERE SUBMITTED SHOWING SCOPE OF WORK. | | PROVIDE COMPLETE INFORMATION FOR REVIEW. SEC. 107.2.1 | | CITY AMENDMENTS TO FBC. ***NOTE: COORDINATE WITH ITEM | | #2 BELOW. | | | | 2- IT LOOKS LIKE THIS PERMIT WAS APPLIED FOR TO REVOKE | | EXPIRED PERMIT APPLICATION #10110532. PERMIT | | APPLICATION #10110532 WAS NEVER APPROVED BECAUSE | | COMMENTS WERE NEVER ADDRESSED. PLEASE REVISE SCOPE OF | | WORK TO MATCH SCOPE OF WORK SUBMITTED ON PERMIT | | APPLICATION #10110532. THE FOLLOWING IS THE SCOPE OF | | WORK FOR PERMIT APPLICATION #10110532: "MAIN HOUSE - | | RENOVATION / REPAIRS. ELECTRIC, SHEETROCK, STUCCO, | | CLOSE 2 WINDOWS & 1 DOOR WITH LATHE/STUCCO. INSTALL NEW | | DOOR ON NORTH SIDE & REAR DOOR. ROOF SHINGLES, HVAC AIR | | HANDLER & COMPRESSOR". SEC. 107.2.1 CITY AMENDMENTS TO | | FBC. | | | | 3- REVISE VALUATION TO REFLECT ALL THE SCOPE OF WORK. | | VALUATION TO INCLUDE ALL LABOR AND MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | PROFESSIONAL FEES. SEC. 109.3 CITY AMENDMENTS TO FBC. | | | | 4- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: ALL WINDOW TYPES TO BE REPLACED, | | WINDOW MULLIONS TO BE REPLACED, ALL EXTERIOR DOORS, | | ROOF SHINGLES, | | | | 5- PROVIDE SOME SORT OF KEY PLAN IDENTIFYING ALL | | WINDOWS AND DOORS TO BE REPLACED. CLEARLY SPECIFY TYPE | | AND SIZE OF ALL EXISTING BEDROOM WINDOWS TO BE REPLACED | | AND PROPOSED WINDOW TO BE INSTALLED TO VERIFY | | COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. 604 OF | | 2010 FBC-EXISTING BUILDING. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2015-08-29 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-29 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-29 |
Time |
13:02 |
Sent To |
|
|
Notes |
2015-07-09 13:40:50 | APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN APPROVED | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | FEE(S). | | | | NFPA 72.SECTION 29.8.3.4 SPECIFIC SMOKE DETECTOR | | LOCATION REQUIREMENTS: | | THE INSTALLATION OF SMOKE ALARMS AND SMOKE DETECTORS | | SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: | | (1) SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE | | LOCATED WHERE AMBIENT CONDITIONS, INCLUDING HUMIDITY | | AND TEMPERATURE, ARE OUTSIDE THE LIMITS SPECIFIED BY | | THE MANUFACTURER?S PUBLISHED INSTRUCTIONS. | | (2) SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE | | LOCATED WITHIN UNFINISHED ATTICS OR GARAGES OR IN OTHER | | SPACES WHERE TEMPERATURES CAN FALL BELOW 40?F (4?C) OR | | EXCEED 100?F (38?C). | | (3)*WHERE THE MOUNTING SURFACE COULD BECOME | | CONSIDERABLY WARMER OR COOLER THAN THE ROOM, SUCH AS A | | POORLY INSULATED CEILING BELOW AN UNFINISHED ATTIC OR | | AN EXTERIOR WALL, SMOKE ALARMS AND SMOKE DETECTORS | | SHALL BE MOUNTED ON AN INSIDE WALL. | | (4)*SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE | | INSTALLED WITHIN AN AREA OF EXCLUSION DETERMINED BY A | | 10 FT (3.0 M) RADIAL DISTANCE ALONG A HORIZONTAL FLOW | | PATH FROM A STATIONARY OR FIXED COOKING APPLIANCE, | | UNLESS LISTED FOR INSTALLATION IN CLOSE PROXIMITY TO | | COOKING APPLIANCES. SMOKE ALARMS AND SMOKE DETECTORS | | INSTALLED BETWEEN 10 FT (3.0 M) AND 20 FT (6.1 M) ALONG | | A HORIZONTAL FLOW PATH FROM A STATIONARY OR FIXED | | COOKING APPLIANCE SHALL BE EQUIPPED WITH AN | | ALARM-SILENCING MEANS OR USE PHOTOELECTRIC DETECTION. | | EXCEPTION: SMOKE ALARMS OR SMOKE DETECTORS THAT USE | | PHOTOELECTRIC DETECTION SHALL BE PERMITTED FOR | | INSTALLATION AT A RADIAL DISTANCE GREATER THAN 6 FT | | (1.8 M) FROM ANY STATIONARY OR FIXED COOKING APPLIANCE | | WHEN THE FOLLOWING CONDITIONS ARE MET: | | (A) THE KITCHEN OR COOKING AREA AND ADJACENT SPACES | | HAVE NO CLEAR INTERIOR PARTITIONS OR HEADERS AND | | (B) THE 10 FT (3.0 M) AREA OF EXCLUSION WOULD PROHIBIT | | THE PLACEMENT OF A SMOKE ALARM OR SMOKE DETECTOR | | REQUIRED BY OTHER SECTIONS OF THIS CODE. | | (5)*SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE | | INSTALLED WITHIN A 36 IN. (910 MM) HORIZONTAL PATH FROM | | A DOOR TO A BATHROOM CONTAINING A SHOWER OR TUB. | | (6) SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE | | INSTALLED WITHIN A 36 IN. (910 MM) HORIZONTAL PATH FROM | | THE SUPPLY REGISTERS OF A FORCED AIR HEATING OR COOLING | | SYSTEM AND SHALL BE INSTALLED OUTSIDE OF THE DIRECT | | AIRFLOW FROM THOSE REGISTERS. | | (7) SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE | | INSTALLED WITHIN A 36 IN. (910 MM) HORIZONTAL PATH FROM | | THE TIP OF THE BLADE OF A CEILING-SUSPENDED (PADDLE) | | FAN. | | (8) WHERE STAIRS LEAD TO OTHER OCCUPIED LEVELS, A SMOKE | | ALARM OR SMOKE DETECTOR SHALL BE LOCATED SO THAT SMOKE | | RISING IN THE STAIRWAY CANNOT BE PREVENTED FROM | | REACHING THE SMOKE ALARM OR SMOKE DETECTOR BY AN | | INTERVENING DOOR OR OBSTRUCTION. | | (9) FOR STAIRWAYS LEADING UP FROM A BASEMENT, SMOKE | | ALARMS OR SMOKE DETECTORS SHALL BE LOCATED ON THE | | BASEMENT CEILING NEAR THE ENTRY TO THE STAIRS. | | (10)*FOR TRAY-SHAPED CEILINGS (COFFERED CEILINGS), | | SMOKE ALARMS AND SMOKE DETECTORS SHALL BE INSTALLED ON | | THE HIGHEST PORTION OF THE CEILING OR ON THE SLOPED | | PORTION OF THE CEILING WITHIN 12 IN. (300 MM) | | VERTICALLY DOWN FROM THE HIGHEST POINT. | | (11) SMOKE ALARMS AND DETECTORS INSTALLED IN ROOMS WITH | | JOISTS OR BEAMS SHALL COMPLY WITH THE REQUIREMENTS OF | | 17.7.3.2.4. | | (12) HEAT ALARMS AND DETECTORS INSTALLED IN ROOMS WITH | | JOISTS OR BEAMS SHALL COMPLY WITH THE REQUIREMENTS OF | | 17.6.3. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | 2015-07-06 15:26:30 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
N |
Date |
2015-04-28 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-04-28 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
|
Time |
16:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2015-04-28 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-04-28 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-04-28 |
Time |
15:25 |
Sent To |
|
|
Notes |
2015-04-28 16:01:17 | DATE:4/28/2015 | | PROJECT: 3721 EASTVIEW | | PERMIT#: 14061326 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 4TH ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | SEE BUILDING COMMENTS AS WELL. | | | | 1) PROVIDE A LOAD SUMMARY. NEC 220.16 | | | | 2) PROVIDE AN ELECTRICAL RISER DIAGRAM INDICATING SIZE, | | TYPE AND LOCATION OF THE SERVICE ENTRANCE, | | DISCONNECT(S), FEEDERS, GROUNDING ELECTRODE SYSTEM, | | MAIN(S), AND PANEL(S). | | | | 3) VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS | | HAS A FAULT CURRENT RATING THAT IS SUFFICIENT AT | | NOMINAL CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE | | INTERRUPTED. NEC 110.9 A FAULT CURRENT CALCULATION IS | | REQUIRED. | | | | 4) VERIFY RECEPTACLE SPACING. NEC 210.52 | | | | 5) INDICATE ALL CIRCUIT NUMBERS ON THE FLOOR PLAN | | CORRESPONDING TO THE REQUIRED CIRCUIT IN THE PANEL | | SCHEDULE. | | | | 6) PROVIDE A CIRCUIT DIRECTORY FOR EACH PANEL AND | | SUB-PANEL. EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL | | BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND | | SPECIFIC PURPOSE OR USE. NEC 408.4 | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2014-11-13 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-11-13 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-11-13 |
Time |
10:41 |
Sent To |
|
|
Notes |
2014-11-13 10:50:37 | DATE:11/13/14 | | PROJECT: 3721 EASTVIEW | | PERMIT#: 14061326 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 3RD ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | 1) PLANS AND NOTES ARE CONFLICTING. THE NOTES AND | | APPLICATION INDICATE ELECTRICAL SCOPE CONFORMING TO ALL | | CURRENT FBC AND NEC BUT THE EDITIONS OF THE CODES NOTED | | ARE NOT ACCURATE. THE PLANS WILL BE REVIEWED UNDER THE | | 2010 FBC AND THE 2008 NEC. THE SCOPE OF WORK ON THE | | APLICATION AND THE SCOPE OF WORK THAT APPEARS TO BE | | PROPOSED ON THE PLANS SUBMITTED ARE CONFLICTING. THE | | APPLICATION STATES THAT ONLY REPAIRS ARE TO BE | | PERFORMED INVOLVING 3 SHEETS OF DRYWALL ALONG WITH SOME | | TILE AND PAINT. THE PLANS INDICATE A NEW ELECTRICAL | | PANEL, NEW A/C, SEVERAL NEW OUTLETS, CEILING FANS, AND | | LIGHTS. PLEASE ADDRESS ALL COMMENTS REGARDING THE PALNS | | SUBMITTED. | | | | 2) A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL | | COUNTERTOP SPACE THAT IS 300 MM (12 IN.) OR WIDER. | | RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT | | ALONG THE WALL LINE IS MORE THAN 600 MM (24 IN.) | | MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT | | SPACE. NEC 210.52(C)(1) | | | | 3) PROVIDE AN ELECTRICAL RISER DIAGRAM INDICATING SIZE, | | TYPE AND LOCATION OF THE SERVICE ENTRANCE, | | DICONNECT(S), FEEDERS, GROUNDING ELECTRODE SYSTEM, | | MAIN(S), AND PANEL(S). | | | | 4) AN INTER-SYSTEM BONDING TERMINATION FOR CONNECTING | | INTER-SYSTEM BONDING AND GROUNDING CONDUCTORS REQUIRED | | FOR OTHER SYSTEMS SHALL BE PROVIDED EXTERNAL TO | | ENCLOSURES AT THE SERVICE EQUIPMENT AND AT THE | | DISCONNECTING MEANS FOR ANY ADDITIONAL BUILDINGS OR | | STRUCTURES. NEC 250.94. | | | | 5) VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS | | HAS A FAULT CURRENT RATING THAT IS SUFFICIENT AT | | NOMINAL CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE | | INTERRUPTED. NEC 110.9 A FAULT CURRENT CALCULATION IS | | REQUIRED. | | | | 6) THE CALCULATED LOAD OF A FEEDER OR SERVICE SHALL NOT | | BE LESS THAN THE SUM OF THE LOADS ON THE BRANCH | | CIRCUITS SUPPLIED. NEC 220.40. PROVIDE A LOAD | | CALCULATION IN COMPLIANCE WITH NEC ARTICLE 220 ACTUAL | | LOAD CALCULATION REQUIRED BASED ON THE NEC ARTICLE 220. | | 220.1 SCOPE. THIS ARTICLE PROVIDES REQUIREMENTS FOR | | CALCULATING BRANCH-CIRCUIT, FEEDER, AND SERVICE LOADS. | | PART I PROVIDES FOR GENERAL REQUIREMENTS FOR | | CALCULATION METHODS. PART II PROVIDES CALCULATION | | METHODS FOR BRANCH-CIRCUIT LOADS. PARTS III AND IV | | PROVIDE CALCULATION METHODS FOR FEEDERS AND SERVICES. | | FABRICATING A TOTAL CONNECTED ELECTRICAL DEMAND BASED | | ON A PARTIAL PANEL SCHEDULE IS NOT AN APPROVED METHOD. | | ADDITIONALLY INCLUDE A LOAD FOR THE REAR BUILDING. | | | | 7) FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL SWITCH? | | CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED TO | | PROVIDE ILLUMINATION ON THE EXTERIOR SIDE OF OUTDOOR | | ENTRANCES OR EXIT SWITH GRADE LEVEL ACCESS. A VEHICLE | | DOOR IN A GARAGE SHALL NOT BE CONSIDERED AS AN OUTDOOR | | ENTRANCE OR EXIT.. NEC 210.70(A)(2) INDICATE ALL | | REQUIRED SWITCHES AND LIGHTS REQUIRED. | | | | 8) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER | | RESISTANT AND AFCI PROTECTED. NEC 210.12, 406.11(C)(2) | | | | 9) FOR ATTICS, UNDERFLOOR SPACES, UTILITY ROOMS, AND | | BASEMENTS, AT LEAST ONE LIGHTING OUTLET CONTAINING A | | SWITCH OR CONTROLLED BY A WALL SWITCH SHALL BE | | INSTALLED WHERE THESE SPACES ARE USED FOR STORAGE OR | | CONTAIN EQUIPMENT REQUIRING SERVICING. AT LEAST ONE | | POINT OF CONTROL SHALL BE AT THE USUAL POINT OF ENTRY | | TO THESE SPACES. THE LIGHTING OUTLET SHALL BE PROVIDED | | AT OR NEAR THE EQUIPMENT REQUIRING SERVICING. NEC | | 210.70(3) | | | | 10) PERMANENT LADDERS OR STAIRWAYS SHALL BE PROVIDED TO | | GIVE SAFE ACCESS TO THE WORKING SPACE AROUND ELECTRICAL | | EQUIPMENT INSTALLED ON PLATFORMS, BALCONIES, OR | | MEZZANINE FLOORS OR IN ATTIC OR ROOF ROOMS OR SPACES. | | NEC 110.33(B) | | | | 11) DISCONNECTING MEANS SHALL BE LOCATED WITHIN SIGHT | | FROM AND READILY ACCESSIBLE FROM THE AIR-CONDITIONING | | OR REFRIGERATING EQUIPMENT. THE DISCONNECTING MEANS | | SHALL BE PERMITTED TO BE INSTALLED ON OR WITHIN THE | | AIR-CONDITIONING OR REFRIGERATING EQUIPMENT. NEC 440.14 | | | | 12) INDICATE ALL CIRCUIT NUMBERS ON THE FLOOR PLAN | | CORRESPONDING TO THE REQUIRED CIRCUIT IN THE PANEL | | SCHEDULE. | | | | THE ABOVE LISTED NOTES ONLY NAME A FEW. IF THE INTENT | | OF THIS PERMIT APPLICATION AND ASSOCIATED CONSTRUCTION | | DOCUMENTS IS TO COMPLY WITH THE PROVISIONS OF ALL | | CURRENT CODES AND ORDINANCES PLEASE REVISE PLANS TO | | COMPLY WITH THE PROVISIONS OF THE 2008 EDITION OF THE | | NATIONAL ELECTRICAL CODE, THE 2010 EDITION OF THE | | FLORIDA BUILDING CODE AS WELL AS THE WEST PALM BEACH | | AMENDMENTS TO CHAPTER ONE OF THE FLORIDA BUILDING CODE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM, SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO SUBMITTAL AND | | LEAVE THE PREVIOUSLY REVIEWED SHEETS. | | FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME. | | I CAN BE REACHED AT 561-805-6717 OR [email protected] | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2014-10-16 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-10-16 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-10-16 |
Time |
12:29 |
Sent To |
|
|
Notes |
2014-10-16 12:34:51 | 10/16/2014 | | PROJECT: 3721 EASTVIEW | | PERMIT#: 14061326 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 2ND ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | 1) THE ADDRESS ON THE PLANS SUBMITTED DO NOT MATCH THE | | ADDRESS ON THE APPLICATION OR THE ADDRESS ON THE | | ORIGINAL PLANS SUBMITTED. THIS IS NOT THE SAME PROJECT | | THAT WAS SUBMITTED AND REVIEWED PREVIOUSLY. RESUBMIT | | WITH CORRECT PROJECT ADDRESSING THE DENIED COMMENTS | | FROM THE PREVIOUS REVIEW. | | | | YOU CAN SEE ALL CPREVIOUS COMMENTS AT THE FOLLOWING | | WEBSITE: | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | US.ASPX | | | | ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS | | EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER, | | THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB | | ABOVE THE SECOND PERMIT INFORMATION). | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | SHEETS FOR COMPARATIVE REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-07-30 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-07-30 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-07-30 |
Time |
11:25 |
Sent To |
|
|
Notes |
2014-07-30 11:53:54 | DATE: 7/30/2014 | | PROJECT: 3721 EASTVIEW | | PERMIT#: 14061326 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | 1) SEE BUILDING REVIEW COMMENTS. NO PLANS SUBMITTED. | | 2) SCOPE OF WORK AND VALUATION ON APPLICATION DOES NOT | | MATCH REVOKED EXPIRED PERMIT APPLICATION AND PLANS FOR | | AFTER THE FACT PROJECT. REVISE PERMIT VALUATION. FBC | | WPB AMENDMENTS. 109.3 | | | | BUILDING COMMENTS BY JULIO GOMEZ: | | "1- NO PLANS WERE SUBMITTED SHOWING SCOPE OF WORK. | | PROVIDE COMPLETE INFORMATION FOR REVIEW. SEC. 107.2.1 | | CITY AMENDMENTS TO FBC. ***NOTE: COORDINATE WITH ITEM | | #2 BELOW. | | 2- IT LOOKS LIKE THIS PERMIT WAS APPLIED FOR TO REVOKE | | EXPIRED PERMIT APPLICATION #10110532. PERMIT | | APPLICATION #10110532 WAS NEVER APPROVED BECAUSE | | COMMENTS WERE NEVER ADDRESSED. PLEASE REVISE SCOPE OF | | WORK TO MATCH SCOPE OF WORK SUBMITTED ON PERMIT | | APPLICATION #10110532. THE FOLLOWING IS THE SCOPE OF | | WORK FOR PERMIT APPLICATION #10110532: "MAIN HOUSE - | | RENOVATION / REPAIRS. ELECTRIC, SHEETROCK, STUCCO, | | CLOSE 2 WINDOWS & 1 DOOR WITH LATHE/STUCCO. INSTALL NEW | | DOOR ON NORTH SIDE & REAR DOOR. ROOF SHINGLES, HVAC AIR | | HANDLER & COMPRESSOR". SEC. 107.2.1 CITY AMENDMENTS TO | | FBC." | | 3- REVISE VALUATION TO REFLECT ALL THE SCOPE OF WORK. | | VALUATION TO INCLUDE ALL LABOR AND MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | PROFESSIONAL FEES. SEC. 109.3 CITY AMENDMENTS TO FBC." | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: HTTP://WPB.ORG/DEVELOPMENT | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | ITTAL_FORM_04132010.PDF | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | SHEETS FOR COMPARATIVE REVIEW. | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | | | | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
5 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-08-26 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-08-26 |
Time |
14:07 |
Sent To |
|
|
Notes |
2015-08-26 14:08:41 | NO OBSCURE GLASS |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
F |
Date |
2015-06-19 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-06-19 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-06-19 |
Time |
11:49 |
Sent To |
|
|
Notes |
2015-06-19 11:49:56 | COMMENTS FROM LAST REVIEW NOT ADDRESSED. QUESTIONS | | CONTACT FRIEDERIKE MITTNER AT 822-1457. | 2015-06-04 17:30:49 | NEW PLANS SUBMITTED. JG. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
F |
Date |
2015-04-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-04-08 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-03-31 |
Time |
15:31 |
Sent To |
|
|
Notes |
2015-04-08 11:11:21 | NEW FRONT PROCH REQURIES APPROVAL BY THE HPB. OWNER | | NEEDS TO SUBMIT COA FOR APPROVAL. SAHLLNOT USE OBSCURE | | WINDOW ON FRONT FACADE. QUESTIONS CONTACT FRIEDERIEK | | MITTNER AT 822-1457. | 2015-03-09 12:01:16 | NEW PLANS SUBMITTED. JG. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2014-10-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-10-30 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-10-30 |
Time |
13:24 |
Sent To |
|
|
Notes |
2014-10-15 17:54:42 | SEE BUILDING COMMENTS DATED 7/29/14. JG. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
N |
Date |
2014-09-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-07-30 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2014-07-09 17:10:52 | 7/9/14 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2015-09-02 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-09-02 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-09-02 |
Time |
16:55 |
Sent To |
|
|
Notes |
2015-09-01 15:19:38 | RESUB ROUTED TO GJOHNSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2015-09-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-09-01 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-07-21 |
Time |
17:43 |
Sent To |
|
|
Notes |
2015-07-30 17:43:40 | RE-SUBMITTAL SENT TO R12 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2015-07-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-07-21 |
Time |
17:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-04 |
Time |
17:29 |
Sent To |
|
|
Notes |
2015-07-30 17:45:38 | NEW PACKAGE WAS RE-SUBMITTED ON 7/21/15. JG. | 2015-06-04 17:29:49 | RE-SUBMITTAL SENT TO R9 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2015-04-28 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-04-28 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-03-06 |
Time |
11:59 |
Sent To |
|
|
Notes |
2015-04-25 12:30:49 | SENT TO D HAYES | 2015-03-09 11:59:56 | RE-SUBMITTAL SENT TO R11 BIN FOR REVIEW. JG. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-11-13 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-11-13 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-10-23 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-10-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-10-15 |
Time |
17:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-09-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-08-18 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-06-30 |
Time |
09:06 |
Sent To |
|
|
Notes |
2014-09-03 08:57:44 | LAST REVIEW DONE ON 8/18/14. JG. | 2014-07-07 09:06:46 | R12 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
N |
Date |
2015-09-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-09-01 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-09-01 |
Time |
09:34 |
Sent To |
|
|
Notes |
2015-09-01 09:35:19 | 7/10/15 MET WITH CONTRACTOR DAVID BOWDEN. ALL A/C | | INFORMATION TO BE SUBMITTED UNDER A SEPARATE PERMIT. | | JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
F |
Date |
2015-07-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-07-06 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-07-06 |
Time |
15:22 |
Sent To |
|
|
Notes |
2015-07-06 15:23:32 | RESIDENTIAL (R3) ALTERATION/ ADDITION FOURTH MECHANICAL | | REVIEW CHECKLIST. | | CODE: 2010 FBC. | | | | 1- PROVIDE COMPLETE AND CORRECT INFORMATION FOR | | MECHANICAL REVIEW. PROVIDE A/C PLANS AND EQUIPMENT | | SIZING CALCULATIONS SHOWING THE MANUFACTURER'S MODEL | | AND NUMBER AS REQUIRED BY SEC. 403.6 OF 2010 FBC-ENERGY | | CONSERVATION. ALSO, SHOW THE EQUIPMENT INFORMATION ON | | THE A/C PLAN. | | | | ***NOTE: THERE ARE NOT MECHANICAL PERMITS FOR THIS | | HOUSE. ANY MECHANICAL WORK WAS DONE WITHOUT PERMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2015-04-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-04-13 |
Time |
17:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-04-13 |
Time |
17:27 |
Sent To |
|
|
Notes |
2015-04-13 17:27:31 | RESIDENTIAL (R3) ALTERATION THIRD MECHANICAL REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE COMPLETE INFORMATION FOR MECHANICAL REVIEW. | | PROVIDE A/C PLANS AND EQUIPMENT SIZING CALCULATIONS | | SHOWING THE MANUFACTURER'S MODEL AND NUMBER AS REQUIRED | | BY SEC. 403.6 OF 2010 FBC-ENERGY CONSERVATION. ALSO, | | SHOW THE EQUIPMENT INFORMATION ON THE A/C PLAN. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2014-11-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-07 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-07 |
Time |
11:21 |
Sent To |
|
|
Notes |
2014-11-07 11:22:07 | RESIDENTIAL (R3) ALTERATION THIRD MECHANICAL REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE COMPLETE INFORMATION FOR MECHANICAL REVIEW. | | PROVIDE A/C PLANS AND EQUIPMENT SIZING CALCULATIONS | | SHOWING THE MANUFACTURER'S MODEL AND NUMBER AS REQUIRED | | BY SEC. 403.6 OF 2010 FBC-ENERGY CONSERVATION. ALSO, | | SHOW THE EQUIPMENT INFORMATION ON THE A/C PLAN. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2014-10-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-10-15 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-10-15 |
Time |
17:55 |
Sent To |
|
|
Notes |
2014-10-15 17:57:05 | RESIDENTIAL (R3) ALTERATION SECOND MECHANICAL REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | ***NOTE: | | FLOOR PLANS AND INFORMATION SUBMITTED IS FOR 635 37TH | | STREET. THIS IS THE INCORRECT ADDRESS FOR THIS PERMIT | | APPLICATION. NEED TO PROVIDE COMPLETE INFORMATION | | ADDRESSING THE ORIGINAL COMMENTS BELOW: | | | | | | 1- PROVIDE COMPLETE INFORMATION FOR MECHANICAL REVIEW. | | PROVIDE A/C PLANS AND EQUIPMENT SIZING CALCULATIONS | | SHOWING THE MANUFACTURER'S MODEL AND NUMBER AS REQUIRED | | BY SEC. 403.6 OF 2010 FBC-ENERGY CONSERVATION. ALSO, | | SHOW THE EQUIPMENT INFORMATION ON THE A/C PLAN. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2014-07-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-07-29 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-07-29 |
Time |
11:45 |
Sent To |
|
|
Notes |
2014-07-29 11:46:11 | RESIDENTIAL (R3) ALTERATION MECHANICAL REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE COMPLETE INFORMATION FOR MECHANICAL REVIEW. | | PROVIDE A/C PLANS AND EQUIPMENT SIZING CALCULATIONS | | SHOWING THE MANUFACTURER'S MODEL AND NUMBER AS REQUIRED | | BY SEC. 403.6 OF 2010 FBC-ENERGY CONSERVATION. ALSO, | | SHOW THE EQUIPMENT INFORMATION ON THE A/C PLAN. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2015-09-02 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-09-02 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-09-02 |
Time |
16:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2015-08-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-08-06 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-08-06 |
Time |
15:18 |
Sent To |
|
|
Notes |
2015-08-06 15:57:05 | 1ST REVIEW FBCP | | | | COMMENT | | | | 1.PAGE A-1 SCOPE OF WORK SHOWS NEW BATHROOM. A RISER | | DIAGRAM IS REQUIERD FOR SANITY AND WATER. | | WPB AMENDMENTS TO FBC 2010 SEC. 107.3.5.3[11] | | | | 2. VALUATION FOR SCOPE OF WORK APPEARS LOW SUBMIT | | SIGNED CONTRACT OR DETAILED | | ESTIMATE PER WPB AMEND TO FBC SEC 109.3 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | EX. 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-07-08 |
|
|
Cont ID |
|
Sent By |
TLARGE |
Date |
2015-07-08 |
Time |
05:47 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-07-08 |
Time |
05:41 |
Sent To |
|
|
Notes |
2015-07-08 05:25:23 | 1) I AM THOROGHLY CONFUSED AS TO THE SCOPE OF PLUMBING | | WORK BEING DONE AND TO WHICH STRUCTURE. | | NOTHING ON THE PLANS MATCH FOR THE PLUMBING. THE | | SANITARY RISER DIAGRAMS ON THE PLANS AND THE ONES ON | | THE 8 1/2 X 11 SHEETS DO NOT MATCH THE FLOOR PLANS. | | IDENTIFY ON THE RISER DIAGRAMS TO WHICH BULDING THEY | | APPLY. I CANNOT COMPLETE MY REVIEW UNTIL A SET OF PLANS | | ARE SUBMITTED THAT CLEARY REFLECT THE COMPLETE SCOPE OF | | PLUMBING WORK TO BE DONE. WPB AMEND. TO 201 FBC | | SEC.107.2.1. | | 2) THE PLANS SHOW BUILDING #2 AS A GARAGE YET THERE IS | | A PLUMBING RISER THAT SHOWS PLUMBING FIXTURES. | | CLARIFY.WPB AMEND. TO 201 FBC SEC.107.2.1. | | 3) IDENTIFY ON EACH FLOOR PLAN WHICH BUILDING NUMBER IT | | IS.WPB AMEND. TO 201 FBC SEC.107.2.1. | | 4) THE LAYOUT OF THE FIXTURES ON THE RISER DIAGRAMS DO | | NOT CORRELATE WITH THE FLOOR PLAN.WPB AMEND. TO 201 FBC | | SEC.107.2.1. | | 5) THEWASHING MACHINE IN THE LAUNDRY IS NOT SHOWN ON | | ANY OF THE PLUMBING RISERS.WPB AMEND. TO 201 FBC | | SEC.107.2.1. | | I SUGGEST CALLING ME TO SET UP AN APPOINTMENT TO GO | | OVER THE COMMENTS. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-09 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-09 |
Time |
11:33 |
Sent To |
|
|
Notes |
2015-04-09 11:40:44 | 1) I AM THOROGHLY CONFUSED AS TO THE SCOPE OF PLUMBING | | WORK BEING DONE AND TO WHICH STRUCTURE. | | NOTHING ON THE PLANS MATCH FOR THE PLUMBING. THE | | SANITARY RISER DIAGRAMS ON THE PLANS AND THE ONES ON | | THE 8 1/2 X 11 SHEETS DO NOT MATCH THE FLOOR PLANS. | | IDENTIFY ON THE RISER DIAGRAMS TO WHICH BULDING THEY | | APPLY. I CAN COMPLETE MY REVIEW UNTIL A SET OF PLANS | | ARE SUBMITTED THAT CLEARY REFLECT THE COMPLETE SCOPE OF | | PLUMBING WORK TO BE DONE. WPB AMEND. TO 201 FBC | | SEC.107.2.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2015-08-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-08-14 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-08-14 |
Time |
14:54 |
Sent To |
|
|
Notes |
2015-08-14 14:55:21 | SHINGLES NOA 12-0309.01 SUBMITTED. JG. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2015-07-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-07-06 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-07-06 |
Time |
15:24 |
Sent To |
|
|
Notes |
2015-07-06 15:25:41 | NOTE: THESE COMMENTS APPLY TO FRONT AND REAR BUILDINGS. | | DRAWINGS A-1 TO A-5 SUBMITTED ARE FOR BOTH STRUCTURES: | | | | 1- CLARIFY WHERE IS THE GAF MINERAL GUARD RESIDENTIAL | | ROLL ROOFING UNDERLAYMENT (NOA 13-1104.03) SUBMITTED | | GOING TO BE INSTALLED? SEC. 107.2.1 CITY AMENDMENTS. | | | | 2- CLARIFY WHERE IS THE GAF CONVENTIONAL BUILT-UP ROOF | | SYSTEM (NOA 13-1022.15) SUBMITTED GOING TO BE | | INSTALLED?. SEC. 107.2.1 CITY AMENDMENTS. PLANS CALL | | FOR EXISTING FLAT ROOF ON REAR BUILDING. NO RE-ROOF. IF | | THIS BUILDING IS GOING TO BE RE-ROOFED, THEN NEED TO | | IDENTIFY SPECIFIC ASSEMBLY TO BE INSTALLED AND PROVIDE | | SIGNED AND SEALED RAS 117 CALCULATIONS AS REQUIRED BY | | GENERAL LIMITATION #7 ON LAST PAGE OF THE NOA. | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: | | A) ROOF SHINGLES. (REPEAT COMMENT. NO PRODUCT APPROVAL | | SUBMITTED). | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2014-11-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-11-07 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-11-07 |
Time |
09:14 |
Sent To |
|
|
Notes |
2014-11-07 09:14:57 | NO ROOF WORK ON THIS REVIEW. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-08-26 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-08-26 |
Time |
14:07 |
Sent To |
|
|
Notes |
2015-07-30 17:48:37 | NEW PLANS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2015-06-19 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-06-19 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-06-19 |
Time |
11:50 |
Sent To |
|
|
Notes |
2015-06-04 17:31:07 | NEW PLANS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2015-04-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-04-08 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-04-08 |
Time |
11:10 |
Sent To |
|
|
Notes |
2015-03-09 12:00:58 | NEW PLANS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2014-10-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-10-30 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-10-30 |
Time |
13:24 |
Sent To |
|
|
Notes |
2014-10-15 17:53:04 | SEE BUILDING COMMENTS DATED 7/29/14. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2014-09-08 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-07-30 |
Time |
07:43 |
Rev Time |
|
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2014-07-30 13:50:06 | 7/30/14 ZONING SENT TO FM. SG |
|
|