Plan Review Stops For Permit 14061115 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2014-07-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-07-30 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-07-30 |
Time |
09:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2014-07-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-07-29 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-07-29 |
Time |
08:10 |
Sent To |
|
|
Notes |
2014-07-29 08:10:53 | 2010 FBC | | | | DENIED BY BUILDING | | | | THE FOLLOWING COMMENTS FROM THE PREVIOUS REVIEW WERE | | NOT CORRECTED. | | | | 2) THE BUILDING DATA ON SHEET A-0.1 IS NOT CONSISTENT | | WITH THE MASTER PERMIT DRAWINGS. THE CONDITIONED SPACE | | IS 1072 SQFT ON THE MASTER PLAN AND 1096 SQFT ON THE | | PLAN SUBMITTED FOR PERMIT. THIS AFFECTS THE SQUARE FOOT | | TOTAL AS WELL. PLEASE CORRECT. | | | | 3) THE LENGTH OF THE NORTH WALL OF THE DWELLING IS | | INCORRECTLY LISTED AS 34'. IT SHOULD BE 32'-4". | | (32.33') PLEASE CORRECT. | | | | 4) PROVIDE A SURFACE DRAINAGE PLAN THAT SHOWS | | COMPLIANCE WITH FBCR 401.3. THIS CAN BE SHOWN ON THE | | SITE PLAN THAT IS SUBMITTED FOR PERMIT. | | | | 5) PLEASE IDENTIFY THE MODEL IN THE TITLE BLOCK OF THE | | SITE PLAN THAT IS SUBMITTED FOR PERMIT. CITY AMENDMENTS | | 107.2.1 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-07-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-07-07 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-07-07 |
Time |
16:49 |
Sent To |
|
|
Notes |
2014-07-07 16:49:40 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE PERMITS CAN NOT BE ISSUED UNTIL THE MASTERED | | PLAN HAS BEEN APPROVED. | | | | 2) THE BUILDING DATA ON SHEET A-0.1 IS NOT CONSISTENT | | WITH THE MASTER PERMIT DRAWINGS. THE CONDITIONED SPACE | | IS 1072 SQFT ON THE MASTER PLAN AND 1096 SQFT ON THE | | PLAN SUBMITTED FOR PERMIT. THIS AFFECTS THE SQUARE FOOT | | TOTAL AS WELL. PLEASE CORRECT. | | | | 3) THE LENGTH OF THE NORTH WALL OF THE DWELLING IS | | INCORRECTLY LISTED AS 34'. IT SHOULD BE 32'-4". | | (32.33') PLEASE CORRECT. | | | | 4) PROVIDE A SURFACE DRAINAGE PLAN THAT SHOWS | | COMPLIANCE WITH FBCR 401.3. THIS CAN BE SHOWN ON THE | | SITE PLAN THAT IS SUBMITTED FOR PERMIT. | | | | 5) PLEASE IDENTIFY THE MODEL IN THE TITLE BLOCK OF THE | | SITE PLAN THAT IS SUBMITTED FOR PERMIT. CITY AMENDMENTS | | 107.2.1 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-06-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:04 |
Sent To |
|
|
Notes |
2014-06-25 15:04:51 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE PERMITS CAN NOT BE ISSUED UNTIL THE MASTERED | | PLAN HAS BEEN APPROVED. | | | | 2) SUBMIT TWO SETS OF SURVEYS OR SITE PLANS WITH THE | | PROPOSED STRUCTURE AND DISTANCES TO PROPERTY LINES | | SPECIFIED ON IT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2014-06-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-07-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-07-29 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-07-25 |
Time |
09:22 |
Sent To |
|
|
Notes |
2014-07-28 09:23:11 | RE-SUBMITTAL SENT TO ROBERT MCDOUGAL'S DESK FOR REVIEW. | | JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-07-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-07-07 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-06-24 |
Time |
15:05 |
Sent To |
|
|
Notes |
2014-06-25 15:05:25 | SENT TO ZONING |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2014-07-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-07-07 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-07-07 |
Time |
16:50 |
Sent To |
|
|
Notes |
2014-07-07 16:51:58 | MU2014-14718 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2014-06-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:04 |
Sent To |
|
|
Notes |
2014-06-25 15:07:15 | SUBMIT THE PLAN WITH THE COUNTY IMPACT REVIEW STAMP AND | | A COPY OF THE PAID IMPACT FEE RECEIPT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2014-06-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2014-06-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-06-25 |
Time |
15:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-06-26 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2014-06-26 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2014-06-26 |
Time |
15:37 |
Sent To |
B |
|
Notes |
|
|