Plan Review Details - Permit 14060881
Plan Review Stops For Permit 14060881 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2014-08-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-08-30 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-08-30 |
Time |
09:30 |
Sent To |
|
|
Notes |
2014-08-30 09:58:11 | BUILDING PROVISO: BEDROOMS MUST MEET THESE | | REQUIREMENTS: | | | | R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. | | R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND | | RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING | | OF 5.7 SQUARE FEET. | | EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM | | NET CLEAR OPENING OF 5 SQUARE FEET (0.465 M2). | | R310.1.2 MINIMUM OPENING HEIGHT. THE MINIMUM NET CLEAR | | OPENING HEIGHT SHALL BE 24 INCHES (610 MM). | | R310.1.3 MINIMUM OPENING WIDTH. THE MINIMUM NET CLEAR | | OPENING WIDTH SHALL BE 20 INCHES (508 MM). | | R313.3 SMOKE ALARMS. LOCATION | | SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING | | LOCATIONS: | | 1. IN EACH SLEEPING ROOM. | | 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE | | VICINITY OF THE BEDROOMS. | | | | | 2014-06-20 14:24:39 | MASTER PERMIT #14050971 BUILDING REVIEW BY SHILL |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2014-09-02 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-02 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-09-02 |
Time |
08:20 |
Sent To |
|
|
Notes |
2014-09-02 08:30:54 | DATE: 9/2/2014 | | PROJECT: BATHROOM ADDITION | | PERMIT#: MASTER 14050971, PLUMBING 14060881, REVISION | | TRACKING #14060885 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 2ND ELECTRICAL PLAN REVIEW | | ACTION: POVISO | | | | ELECTRICAL SCOPE FOR THIS BATHROOM ADDITION COVERED | | UNDER ELECTRICAL PERMIT APPLICATION #14080935. | | ELECTRICAL PERMIT 14080935 NOT APPROVED OR ISSUED YET. | | THEREFORE THE ELECTRICAL SCOPE OF WORK INVOLVED AND | | REQUIRED FOR THIS BATHROOM ADDITION AND INSPECTIONS FOR | | SAME CANNOT PROCEED UNTILL ELECTRICAL PERMIT#14080935 | | HAS BEEN ISSUED. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-06-20 |
|
|
Cont ID |
|
Sent By |
dah |
Date |
2014-06-20 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-06-20 |
Time |
14:18 |
Sent To |
P |
|
Notes |
2014-06-20 14:21:44 | PROJECT: 640 FORREST HILLS BLVD | | PERMIT#: 14060881 | | CODE: 2008 EDITION OF THE NEC. | | 2010 EDITION OF THE FBC, | | 2010 EDITION OF THE WPB AMENDMENTS TO THE FBC, CHAPTER | | 1, ADMINISTRATION | | 2009 EDITION OF NFPA 101 | | | | 1ST ELECTRICAL REVIEW | | | | ACTION: DENIED | | | | 1) NO ELECTRICAL PLANS OR DETAILS PROVIDED. ELECTRICAL | | PERMIT AND PLANS REQUIRED TO INDICATE ANY AND ALL | | ALTERATIONS AND INSTALLATIONS OF ELECTRICAL CIRCUITRY | | FOR POWER OUTLETS AND LIGHTING. FBC 107.2.1 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-09-02 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-09-02 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-08-25 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-08-30 |
|
|
Cont ID |
|
Sent By |
|
Date |
2014-08-30 |
Time |
|
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-06-20 |
Time |
12:43 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2014-08-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-08-30 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-08-30 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
|