Plan Review Details - Permit 14060547
Plan Review Stops For Permit 14060547 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-06-24 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-06-24 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-06-24 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-06-16 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-06-16 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-06-16 |
Time |
14:50 |
Sent To |
|
|
Notes |
2014-06-16 15:26:19 | DATE: 6/16/2014 | | PROJECT: GAINES PARK BASKETBALL REPLACEMENT | | PERMIT#: 14060547 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | ELECTRICAL PLAN REVIEW | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) EACH MULTI-WIRE BANCH CIRCUIT SHALL BE PROVIDED WITH | | A MEANS THAT WILL SIMULTANTOIUSLY DISCONNECT ALL | | UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH | | CIRCUIT ORIGINATES. 210.4 (B) INDICATE IF THE DEDICATED | | CIRCUIT ALSO IMPLIES A DEDICATED NEUTRAL. | | | | 2) INDICATE THE LOCATION AND WIRINF MEATHOD FOR THE | | ELEVATION KEY SWITCH. THE MANUFACTURER NOTES CALL FOR A | | KEY SWITCH FOR OPERATION OF THE ELEVATION OF THE GOAL. | | THE ELECTRICAL PLANS DO NOT INDICATE THE LOCATION OR | | WIRING MEATHOD FOR THE KEY SWITCH. | | | | 3) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN. FBC 107.2.1. | | KNIGHT ELECTRIC IS NOT THE PERSON RESPONSIBLE FOR THE | | DESIGN. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER. PX3421, | | 561-805-6717, [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-06-24 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-06-24 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-06-23 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-06-16 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-06-16 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-06-13 |
Time |
14:50 |
Sent To |
|
|
Notes |
2014-06-13 11:22:14 | ROUTED TO ELECTRICAL |
|
|
|