Plan Review Details - Permit 14060014
Plan Review Stops For Permit 14060014
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-07-03 Cont ID  
Sent By shill Date 2014-07-03 Time 10:20 Rev Time 0.00
Received By shill Date 2014-07-03 Time 10:20 Sent To  
Notes
2014-07-03 11:04:53****PROVISO****
 ****ISSUED AT CONTRACTOR'S RISK****
  
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 COMMENT NOT ADDRESSED - CALCULATIONS NOT PROVIDED, WIND
 DESIGN NOT CHANGED, SEAL DIFFICULT TO READ, FASTENER
 SIZE REDUCED FROM FIRST REVIEW
  
 PER CONVERSATION WITH RALPH LASHELLS, QUALIFIER,
 ADDITIONAL FASTENERS WILL BE INSTALLED. A MINIMUM OF
 EIGHT FASTENERS IS RECOMMENDED.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-06-14 Cont ID  
Sent By shill Date 2014-06-14 Time 16:33 Rev Time 0.00
Received By shill Date 2014-06-14 Time 16:33 Sent To  
Notes
2014-06-14 16:33:44****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PROVIDE CALCULATIONS TO SHOW THAT THE FOUR ANCHORS
 IS ADEQUATE FOR THE PROPOSED SIGN TO RESIST WIND LOADS.
 ALSO PROVIDE A FASTENING PATTERN; ARE THE FOUR TO BE
 ONE ON EACH CORNER? AS THE SIGN IS 8'6" LONG, IT
 APPEARS THAT INTERMEDIATE FASTENERS MAY BE REQUIRED.
  
 2. WIND DESIGN CRITERIA NOT CLEAR. BOTH 160MPH AND
 180MPH 3 SECOND GUST PER FBC2010 REFERENCED. LANGUAGE
 IS CONFUSING.
  
 3. SEAL IS ILLEGIBLE, FAC61G15-23.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-06-28 Cont ID  
Sent By dhayes Date 2014-06-28 Time 13:45 Rev Time 0.00
Received By dhayes Date 2014-06-28 Time 13:45 Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-06-12 Cont ID  
Sent By albarran Date 2014-06-12 Time 12:10 Rev Time 0.00
Received By albarran Date 2014-06-12 Time 11:53 Sent To B
Notes
2014-06-12 12:16:06IF NOT ALREADY IN PLACE, THIS SIGN SHALL BE CONNECTED
 TO A TIME CLOCK TO COMPLY WITH THE FLORIDA BUILDING
 CODE-ENERGY CONSERVATION, SECTION 505
  
 ROUTED TO B >$5K

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-07-03 Cont ID  
Sent By shill Date 2014-07-03 Time 11:05 Rev Time 0.00
Received By shill Date 2014-06-27 Time 13:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-06-14 Cont ID  
Sent By shill Date 2014-06-14 Time 16:33 Rev Time 0.00
Received By shill Date 2014-06-02 Time 11:17 Sent To  
Notes
2014-06-02 11:18:05ZONING
  

Review Stop Z ZONING
Rev No 2 Status P Date 2014-07-02 Cont ID  
Sent By ajones Date 2014-07-02 Time 16:10 Rev Time 0.00
Received By ajones Date 2014-07-02 Time 16:10 Sent To B
Notes
2014-06-30 12:58:356/30/14 ZONING SENT TO AV. SG

Review Stop Z ZONING
Rev No 1 Status P Date 2014-06-11 Cont ID  
Sent By ajones Date 2014-06-11 Time 15:33 Rev Time 0.00
Received By ajones Date 2014-06-11 Time 15:33 Sent To  
Notes
2014-06-02 14:37:016/2/14 ZONING SENT TO AV. SG