Plan Review Details - Permit 14050847
Plan Review Stops For Permit 14050847
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-07-23 Cont ID  
Sent By skennedy Date 2014-07-23 Time 07:46 Rev Time 0.00
Received By skennedy Date 2014-07-23 Time 07:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-07-09 Cont ID  
Sent By skennedy Date 2014-07-09 Time 15:20 Rev Time 0.00
Received By skennedy Date 2014-07-09 Time 15:20 Sent To  
Notes
2014-07-09 15:26:522ND REVIEW:
  
 THE STRUCTURE ON THE PROPOSED SURVEY IS 5 FEET WIDER
 THAN THE HOUSE ON THE PLANS. ACCORDINGLY, THE SET BACK
 FOR THE RIGHT SIDE IS OFF BY 5 FEET ON THE SITE PLAN
 VERSUS THE SURVEY. PROVIDE A CORRECTED PROPOSED SURVEY.
 WHEN YOU DO SO, YOU SHOULD ALSO PROVIDE THE DRIVEWAY
 LAYOUT AND ASSOCIATE IT WITH THE DRIVEWAY PERMIT
 APPLICATION YOU SUBMITTED PREVIOUSLY. IT IS 14061329,
 SEE TO IT THAT IT GETS TO ENGINEERING AND ZONING FOR
 REVIEW.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-06-24 Cont ID  
Sent By skennedy Date 2014-06-24 Time 17:02 Rev Time 0.00
Received By skennedy Date 2014-06-24 Time 17:00 Sent To  
Notes
2014-06-24 17:08:261ST REVIEW:
  
 1)THERE IS NO EVIDENCE OF REVIEW BY THE DESIGNER OF
 APPROPRIATENESS OF THE PRODUCT APPROVALS SUBMITTED.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING,
 WINDOW, AND DOOR SUBMITTALS.
  
 2) SEE ZONING COMMENTS REGARDING ELEVATION
 INCONSISTANCIES.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-06-11 Cont ID  
Sent By albarran Date 2014-06-11 Time 18:38 Rev Time 0.00
Received By albarran Date 2014-06-11 Time 16:25 Sent To  
Notes
2014-06-11 18:39:50THE FOLLOWING PROVISOS HAVE BEEN MADE A CONDITION OF
 APPROVAL FOR PERMIT 14050847:
  
 1. ARC-FAULT PROTECTION SHALL COMPLY W/NEC 210.12(B)
 2. SMOKE DET. PLACEMENT SHALL COMPLY W/FBC-R 314 & 315
 3. FEEDER #1 SHALL HAVE A 1/0 CU GEC PER NEC 250.66
 4. INTER-SYSTEM BONDING TERMINAL REQ?D AS PER NEC
 250.94
 5. ALL METAL PIPING SYSTEMS (GAS, COLD WATER,
 STRUCTURAL STEEL ETC. SHALL BE BONDED SHALL BE BONDED
 AS IN NEC 250.104
 6. ALL EXTERIOR RECEPTACLES SHALL BE LISTED ?WR? AS IN
 406.8
 7. TAMPER-RESISTANT RECEPTACLES ARE REQ?D AS PER NEC
 406.11
 THESE PLANS WERE REVIEWED BY MIKE ALBARRAN, ELECTRICAL
 PLANS EXAMINER
 YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE
 FOLLOWING LINK:
  
 HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT
 US.ASPX
  
 ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS
 EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER,
 AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB
 ABOVE THE SECOND PERMIT INFORMATION).
 AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR
 COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER
 PERMIT CONDITIONS.
 FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME.
 I CAN BE REACHED AT 561-805-6718 OR [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-07-23 Cont ID  
Sent By skennedy Date 2014-07-23 Time 07:46 Rev Time 0.00
Received By skennedy Date 2014-07-18 Time 11:42 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-07-09 Cont ID  
Sent By skennedy Date 2014-07-09 Time 15:27 Rev Time 0.00
Received By skennedy Date 2014-06-30 Time 18:24 Sent To  
Notes
2014-06-30 18:24:43R19
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date 2014-06-24 Cont ID  
Sent By skennedy Date 2014-06-24 Time 17:08 Rev Time 0.00
Received By skennedy Date 2014-05-22 Time 17:49 Sent To  
Notes
2014-06-24 17:08:59PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND
 TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED
 WITH A COPY OF RECEIPT AS APPLICABLE
2014-05-23 08:02:20REASSIGNED TO R22
2014-05-22 17:53:36ROUTE TO R4

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2014-07-09 Cont ID  
Sent By skennedy Date 2014-07-09 Time 15:27 Rev Time 0.00
Received By skennedy Date 2014-07-09 Time 15:26 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-06-24 Cont ID  
Sent By skennedy Date 2014-06-24 Time 16:30 Rev Time 0.00
Received By skennedy Date 2014-06-24 Time 16:31 Sent To  
Notes
2014-06-24 16:30:56PBC IMPACT REVIEW REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-06-24 Cont ID  
Sent By skennedy Date 2014-05-28 Time 16:18 Rev Time 0.00
Received By skennedy Date 2014-05-28 Time 16:19 Sent To  
Notes
2014-06-24 16:19:14REVIEW BY HAROLD MOSER

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-06-24 Cont ID  
Sent By hmoser Date 2014-06-24 Time 16:59 Rev Time 0.00
Received By skennedy Date 2014-06-24 Time 16:31 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2014-07-23 Cont ID  
Sent By skennedy Date 2014-07-23 Time 07:36 Rev Time 0.00
Received By skennedy Date 2014-07-23 Time 07:36 Sent To  
Notes
2014-07-23 07:37:03ROOFING

Review Stop Z ZONING
Rev No 3 Status P Date 2014-07-21 Cont ID  
Sent By skennedy Date 2014-07-23 Time 07:46 Rev Time 0.00
Received By llouie Date 2014-07-21 Time 15:02 Sent To B
Notes
2014-07-21 15:04:31ZONING APPROVED.
  
 NOTE: SEPARATE PERMIT AND REVIEW REQUIRED FOR DRIVEWAY.
  
  
2014-07-21 11:26:447/21/14 ZONING SENT TO LL. SG

Review Stop Z ZONING
Rev No 2 Status F Date 2014-07-02 Cont ID  
Sent By llouie Date 2014-07-02 Time 16:01 Rev Time 0.00
Received By llouie Date 2014-07-02 Time 16:01 Sent To  
Notes
2014-07-02 16:02:18** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) DIMENSIONS AND SETBACKS IN THE SURVEY FOR THE
 PROPOSED RESIDENCE DOES NOT MATCH THE SITE
 PLAN/ARCHITECTURAL PLANS, ETC. PLEASE ADDRESS FOR
 CONSISTENCY.
  
 2.) SEPARATE PERMITS AND REVIEWS REQUIRED FOR
 LANDSCAPING, DRIVEWAY AND A/C UNITS.
  
 PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS
 MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE
 @ (561) 822-1458 IF YOU HAVE QUESTIONS.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2014-05-29 Cont ID  
Sent By llouie Date 2014-05-29 Time 09:41 Rev Time 0.00
Received By llouie Date 2014-05-29 Time 09:41 Sent To  
Notes
2014-05-29 09:47:52** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THE SCALE IS INCORRECT IN THE PLANS. PLEASE
 ADDRESS.
  
 2.) ELEVATIONS LABELED INCORRECTLY. PLEASE ADDRESS.
  
 3.) EAST AND WEST ELEVATIONS DO NOT MATCH THE FLOOR
 PLANS. PLEASE ADDRESS.
  
 4.) THE HEIGHT OF THE BUILDING SHALL NOT EXCEED 30 FT.
 THE HEIGHT SHALL BE MEASURED FROM THE GRADE TO THE PEAK
 OF THE ROOF. (ZLDR S.94-72(A)(3))
  
 5.) ANY DECORATIVE FEATURES, PARAPETS, CHIMNEYS, ETC.
 SHALL NOT EXCEED THE DISTRICT HEIGHT REQUIREMENTS BY 10
 PERCENT. (ZLDR S.94-306(A))
  
 6.) THE VALUE OF THE SCOPE OF WORK EXCEEDS 50 PERCENT
 OF THE VALUE OF THE STRUCTURE. THEREFORE, THE PROPERTY
 MUST COME INTO COMPLIANCE WITH ARTICLE XIV,
 LANDSCAPING, OF THE CITY'S ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR). THE LANDSCAPE PLAN SHALL BE
 REVIEWED SEPARATELY. A SEPARATE PERMIT SHALL BE
 SUBMITTED FOR LANDSCAPING. (ZLDR S.94-441(C))
  
 7.) THE TREE AND PALM DISPOSITION PLAN (SHEET LS-1)
 INDICATES THAT TREES AND PALMS WILL BE REMOVED FROM THE
 PROPERTY. NO TREE OR PALM SHALL BE REMOVED AND/OR
 RELOCATED WITHOUT FIRST OBTAINING A TREE ALTERATION
 PERMIT. (ZLDR S.94-448)
  
 8.) THE APPLICATION FOR A TREE ALTERATION PERMIT CAN BE
 FOUND ON THE CITY'S WEBSITE FOLLOWING THIS LINK: HTTP:/
 /WPB.ORG/PLANNING/WP-CONTENT/UPLOADS/SITES/37/2013/04/T
 REEALTERATIONPERMITREVISED03-12-09.PDF
  
 9.) IN A SEPARATE PERMIT FOR LANDSCAPING, PLEASE
 ADDRESS THE FOLLOWING:
 - THE NUMBER OF REQUIRED TREES PROPOSED IS
 INSUFFICIENT. PALMS MAY BE SUBSTITUTED FOR NOT MORE
 THAN 35 PERCENT OF THE REQUIRED SHADE OR FLOWERING
 TREES.
 - PALMS SUBSTITUTED FOR TREES SHALL BE CLUSTERED IN
 GROUPS OF THREE (3) PALMS.
 - AT LEAST ONE (1) SHRUB SHALL BE PLANTED FOR EACH 500
 SQ. FT. OF OPEN SPACE.
  
 10.) PROVIDE MORE INFORMATION ON THE EXISTING ACCESSORY
 STRUCTURE ON THE PROPERTY. WHAT TYPE OF ACCESSORY
 STRUCTURE IS IT AND WHEN WAS IT PERMITTED? A QUICK
 SEARCH DID NOT
  
 11.) SEPARATE PERMITS AND REVIEWS REQUIRED FOR THE
 FOLLOWING: LANDSCAPING, DRIVEWAY AND A/C UNITS.
  
 12.) PLEASE NOTE THAT THERE SEEMS TO BE AN EXISTING
 STRUCTURE ON THE PROPERTY AND THERE IS NO DEMO PERMIT
 ON FILE AT THIS ADDRESS. PLEASE PROVIDE CLARIFICATION.
  
 PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS
 MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE
 @ (561) 822-1458 IF YOU HAVE QUESTIONS.
  
2014-05-28 11:35:545/28/14