Plan Review Details - Permit 14050703
Plan Review Stops For Permit 14050703 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-07-19 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-07-19 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-07-19 |
Time |
12:58 |
Sent To |
|
|
Notes |
2014-07-19 13:08:34 | DATE: 7/19/2014 | | PROJECT: CARDINAL NEWMAN HIGHSCHOOL | | PERMIT#: 14050703 | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: PROVISO | | | | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN. FBC 107.2.1. | | SIGN PLANS PRIOR TO ISSUANCE. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-05-20 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-05-20 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-05-20 |
Time |
12:15 |
Sent To |
|
|
Notes |
2014-05-20 14:14:26 | ELECTRICAL PLAN REVIEW DENIED. SEE THE FOLLOWING | | COMMENTS BASED ON THE LATEST EDITION OF THE NFPA 72, | | THE 2008 NEC AND THE 2010 FBC. | | | | 1) PLANS ARE INCOMPLETE. PLEASE INDICATE THE LOCATION | | OF THE FACP ON THE FLOOR PLAN | | | | 2) RISER INDICATES PULL STATIONS. PLEASE INDICATE PULL | | STATIONS ON THE FLOOR PLAN. | | | | 3) NOTIFICATION APPLIANCE CIRCUIT REQUIRED. PLEASE | | INDICATE NOTIFICATION DEVICES ON THE FLOOR PLAN AND | | RISER. | | | | 4) PLEASE PROVIDE AND INDICATE THE REQUIRED VOLTAGE | | DROP AND BATTERY CALCULATIONS FOR THE NEW DEVICES AND | | CIRCUITS. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR AT [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2014-07-18 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-07-18 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-07-18 |
Time |
11:15 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2014-05-19 |
|
|
Cont ID |
|
Sent By |
rferguso |
Date |
2014-05-19 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rferguso |
Date |
2014-05-19 |
Time |
14:42 |
Sent To |
E |
|
Notes |
2014-05-19 14:48:52 | 512 SPENSER DRIVE | | PERMIT #14050703 | | | | WEST PALM BEACH PLAN REVIEW COMMENTS. | | * NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK | | INFORMATION. | | | | RONALD E. FERGUSON, ASSISTANT FIRE MARSHAL | | BUREAU OF FIRE PREVENTION | | PHONE (561)804-4700 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-07-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-07-19 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-07-17 |
Time |
06:46 |
Sent To |
FIRE |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
F |
Date |
2014-05-20 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-05-20 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-05-19 |
Time |
11:33 |
Sent To |
|
|
Notes |
2014-05-19 11:33:19 | ROUTED TO FIRE |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |