Plan Review Stops For Permit 14050584 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2014-07-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-07-02 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-07-02 |
Time |
07:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-06-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-06-11 |
Time |
18:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-06-11 |
Time |
18:31 |
Sent To |
|
|
Notes |
2014-06-11 18:41:27 | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | NOTE - ORIGINAL APPLICATION WAS REVIEWED AS TEMPORARY | | CONSTRUCTION TRAILER. RESUBMITTAL IS FOR A CARD PLAY | | TRAILER. | | | | 1. REVISE SITE PLAN TO SHOW DISTANCE TO OTHER | | STRUCTURES AND COMPLIANCE WITH FBC 705.8. | | | | 2. SHEET A100, LANDING STAIR SIDE ELEVATION, SEE FBC | | 2010 ACCESSIBILITY 505.10.3 AND FIGURE 505.10.3. THE | | EXTENSION AT THE BOTTOM SHALL CONTINUE AT SLOPE FOR | | DISTANCE OF ONE TREAD. THE REQUIREMENT FOR THE | | ADDITIONAL EXTENSION HAS BEEN REMOVED FROM THE CODE. | | | | 3. DCA APPROVAL SUBMITTED IS FOR TYPE V B BUSINESS | | OCCUPANCY, PROPOSED USE IS ASSEMBLY. PLEASE ADDRESS, | | FBC CHAPTERS 10, 16. | | | | 4. PER WILLIE SWOPE, PALM BEACH COUNTY IMPACT FEES, | | PROVIDE A LETTER WITH A COMMITMENT AS TO REMOVAL DATE. | | THEREFORE NO IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY | | WILL BE REQUIRED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-05-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-05-17 |
Time |
17:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-05-17 |
Time |
17:06 |
Sent To |
Z |
|
Notes |
2014-05-17 17:06:33 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. PROVIDE A SITE PLAN SHOWING PROPOSED LOCATION, FBC | | 107. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2014-06-30 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-06-30 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-06-30 |
Time |
14:37 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2014-06-11 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-06-11 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-06-11 |
Time |
11:06 |
Sent To |
|
|
Notes |
2014-06-11 11:19:47 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | HAVING REVIEWED THE SITE PLAN FOR THE FIRST TIME, THERE | | ARE MULTIPLE TEMPORAY TRAILERS INDICATED IN THE PARKING | | LOT AREA. | | | | THESE TEMPORAY TRAILERS SHALL MEET THE MINIMUM | | SEPARATION DISTANCE REQUIREMENTS OF NFPA 241, CHAPTER | | 4, TABLE 4.2.1. | | | | SEPARATION DISTANCES SHALL BE PROVIDED ON THE SITE | | PLAN. THE TRAILERS SHALL BE SEPARATED ACCORDING TO THE | | INDICATED SEPARATION DISTANCES. | | | | A 75 PERCENT REDUCTION IN SEPARATION DISTANCE SHALL BE | | APPLIED PROVIDED AUTOMATIC SPRINKLER PROTECTION IS USED | | IN THE EXPOSING STRUCTURE. | | | | AS PROPOSED, FIRE SPRINKLER PROTECTION IS REQUIRED IN | | EACH OF THE TRAILERS ON THE SITE PLAN, SPRINKLER | | PROTECTION SHALL BE INDICATED ON THE RESUBMITTED PLAN | | UNDER SEPARATE SHOP DRAWINGS. | | | | ADA COMPLAINT STAIR/RAMP PLANS DO NOT SHOW LOCATIONS AT | | THE THE BUILDING, TO OTHER TRAILERS AND/OR ON THE SITE | | PLAN. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2014-05-20 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-05-20 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-05-20 |
Time |
11:33 |
Sent To |
PC |
|
Notes |
2014-05-20 11:34:33 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | SITE PLAN NOT PROVIDED, INCLUDING ALL DIMENSIONS FROM | | NEAREST STRUCTURES, PARKING LOTS, DRIVEWAYS, ETC. | | | | INDICATION OF HOW LONG THE TEMPORARY TRAILER WILL BE | | THERE IS NOT PROVIDED. | | | | LIFE SAFETY PLAN NOT PROVIDED. | | | | FLOOR PLAN, FURNITURE LOCATIONS NOT PROVIDED. | | | | LIGHTWIEGHT TRUSS FLOOR AND ROOF SIGN NOT PROVIDED. | | | | STAIRS, ADA RAMP DETAILS NOT PROVIDED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2014-07-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-07-02 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-06-26 |
Time |
08:17 |
Sent To |
|
|
Notes |
2014-07-01 08:18:28 | ADA RAMP/STAIR DRAWINGS SENT TO SAMANTHA'S DESK FOR | | REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-07-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-07-02 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-06-26 |
Time |
10:52 |
Sent To |
|
|
Notes |
2014-06-26 10:53:00 | SENT TO FIRE BOX . JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-06-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-06-20 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-06-09 |
Time |
18:01 |
Sent To |
|
|
Notes |
2014-06-11 18:46:32 | 6/11 TO SH DESK | | | 2014-06-09 18:01:43 | TO ZONING | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-05-20 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-05-20 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-05-15 |
Time |
10:25 |
Sent To |
PC |
|
Notes |
2014-05-15 10:25:24 | PUT IN COMM. MISC. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2014-07-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-07-02 |
Time |
07:04 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2014-06-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-06-20 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-06-20 |
Time |
14:37 |
Sent To |
|
|
Notes |
2014-06-20 14:38:00 | PER WILLIE SWOPE, PALM BEACH COUNTY IMPACT FEES, | | COMMITMENT LETTER REGARDING REMOVAL REQUIRED. ADD THIS | | INFORMATION TO PERMIT DESCRIPTION / PERMIT CARD |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2014-06-10 |
Time |
10:49 |
Sent To |
FIRE |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2014-05-19 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2014-05-19 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2014-05-19 |
Time |
15:27 |
Sent To |
FIRE |
|
Notes |
2014-05-19 15:27:47 | 5/19/14 ZONING FAILED | | | | 1. PROVIDE 2- SITE PLANS SHOWING THE LOCATION OF | | TRAILER, LANDSCAPING, PARKING AND HANDICAP | | ACCESSIABLITY. |
|
|