Plan Review Details - Permit 14050167
Plan Review Stops For Permit 14050167
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-08-23 Cont ID  
Sent By jwitmer Date 2014-08-23 Time 10:46 Rev Time 0.00
Received By jwitmer Date 2014-08-23 Time 09:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-07-03 Cont ID  
Sent By JWITMER Date 2014-07-03 Time 07:02 Rev Time 0.00
Received By jwitmer Date 2014-07-03 Time 05:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-05-28 Cont ID  
Sent By pleduc Date 2014-05-29 Time 08:40 Rev Time 0.00
Received By jwitmer Date 2014-05-27 Time 17:26 Sent To  
Notes
2014-05-27 17:31:42BUILDING PLAN REVIEW
 PERMIT: 14050167
 ADD: 400 N FLAGLER DR # PH-D2
 CONT: MARYJULI CONSTRUCTION
 TEL: (561)386-6032
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. MAY 27/ 2014
 ACTION: DENIED
  
 1) DISCREPANCY BETWEEN THE PLANS AND PERMIT
 APPLICATION, THE PLANS INDICATE THE BALCONY DOORS UNDER
 SEPARATE CONTRACT, WHERE AS THE PERMIT APLICATION UNDER
 DESCRIPTION OF WORK INCLUDES WINDOWS & DOORS. 2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, ADMINISTRATION 107.2.1.3. ADDITIONAL
 INFORMATTION IS REQUIRED.
  
 2) 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 2.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 2.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 2.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 2.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 2.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE
 TABLE 1609.2(2) .
  
 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
  
 4) THE PERMIT APPLICATION & PLANS ALSO INDICATE THE
 REMOVAL OF ALL FLOORING BUT THEY DO NOT INDICATE THE
 NEW REPLACEMENT MATERIAL. IF TILE FLOOR AND OR WOOD
 FLOORING ARE BEING INSTALLED SEE THE REQUIRED
 COMPLIANCE SECTIONS LISTED BELOW FOR HIGH RISE
 BUILDINGS TYPE I OR TYPE II:
  
 4A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 4B) FBC-B 2010 603.2 EXCEPTION (1) TILE FLOORING
 FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
  
 4C) FBC-B 2010 603.2 EXCEPTION 2 WOOD FLOORS
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 703.4 NONCOMBUSTIBILITY TESTS.
 THE TESTS INDICATED IN SECTIONS 703.4.1 AND 703.4.2
 SHALL SERVE AS CRITERIA FOR ACCEPTANCE OF BUILDING
 MATERIALS AS SET FORTH IN SECTIONS 602.2, 602.3 AND
 602.4 IN TYPE I, II, III AND IV CONSTRUCTION. THE TERM
 "NONCOMBUSTIBLE" DOES NOT APPLY TO THE FLAME SPREAD
 CHARACTERISTICS OF INTERIOR FINISH OR TRIM MATERIALS. A
 MATERIAL SHALL NOT BE CLASSIFIED AS A NONCOMBUSTIBLE
 BUILDING CONSTRUCTION MATERIAL IF IT IS SUBJECT TO AN
 INCREASE IN COMBUSTIBILITY OR FLAME SPREAD BEYOND THE
 LIMITATIONS HEREIN ESTABLISHED THROUGH THE EFFECTS OF
 AGE, MOISTURE OR OTHER ATMOSPHERIC CONDITIONS.
  
 703.4.1 ELEMENTARY MATERIALS.
 MATERIALS REQUIRED TO BE NONCOMBUSTIBLE SHALL BE TESTED
 IN ACCORDANCE WITH ASTM E 136.
  
 703.4.2 COMPOSITE MATERIALS.
 MATERIALS HAVING A STRUCTURAL BASE OF NONCOMBUSTIBLE
 MATERIAL AS DETERMINED IN ACCORDANCE WITH SECTION
 703.4.1 WITH A SURFACING NOT MORE THAN 0.125 INCH (3.18
 MM) THICK THAT HAS A FLAME SPREAD INDEX NOT GREATER
 THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL
 723 SHALL BE ACCEPTABLE AS NONCOMBUSTIBLE MATERIALS
  
 FBC-B 2010
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2014-08-21 Cont ID  
Sent By dhayes Date 2014-08-21 Time 13:09 Rev Time 0.00
Received By dhayes Date 2014-08-21 Time 13:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2014-07-10 Cont ID  
Sent By DHAYES Date 2014-07-10 Time 09:03 Rev Time 0.00
Received By dhayes Date 2014-07-10 Time 07:40 Sent To  
Notes
2014-07-10 09:03:32DATE: 7/9/2014
 PROJECT: WALDMAN APT.
 PERMIT#: 14050167
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 2ND ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) IN KITCHENS, PANTRIES, BREAKFAST ROOMS, DINING
 ROOMS, AND SIMILAR AREAS OF DWELLING UNITS, RECEPTACLE
 OUTLETS FOR COUNTERTOP SPACES SHALL BE INSTALLED IN
 ACCORDANCE WITH NEC 210.52(C)(1) THROUGH (C)(5). THE
 PLANS DO NOT SHOW THE LOCATIONS OF ANY RECEPTACLE
 OUTLETS REVISE PLANS TO TO SHOW LOCATIONS OF ALL NEW
 OUTLETS INCLUDING ANY ADDITIONAL OUTLETS REQUIRED FOR
 COMPLIANCE IN ACCORDANCE WITH NEC 210.52(C)(1) THROUGH
 (C)(5).
  
 2) RECEPTACLES SHALL BE SPACED SO THAT AT NO POINT
 ALONG THE FLOOR IN ANY WALL IS MORE THAN 6 FEET FROM A
 RECEPTACLE OUTLET. NEC 210.52 (A)(2).THE PLANS DO NOT
 SHOW THE LOCATIONS OF ANY RECEPTACLE OUTLETS EXCEPT FOR
 SOME REQUIRED FOR NEW MOTORIZED BLINDS.. REVISE PLANS
 TO TO SHOW LOCATIONS OF ALL NEW OUTLETS INCLUDING ANY
 ADDITIONAL OUTLETS REQUIRED FOR COMPLIANCE IN
 ACCORDANCE WITH NEC 210.52 (A)(2)
  
 3) PROVIDE PRODUCT APPROVALS AND INSTALLATION DETAILS
 FOR MOTORIZED BLINDS. LISTING AND LABELING REQUIRED BY
 AN APPROVED TESTING LAB. IN JUDGING EQUIPMENT,
 CONSIDERATION SUCH AS THE FOLLOWING SHALL BE EVALUATED:
 SUITABILITY OF EQUIPMENT MAY BE EVIDENCED BY LISTING OR
 LABELING. SUITABILITY FOR INSTALLATION AND USE IN
 CONFORMITY WITH THE PROVISIONS OF THIS CODE. NEC
 110.3(A)(1 THRU 8) LISTED OR LABELED EQUIPMENT SHALL BE
 INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS
 INCLUDED IN THE LISTING AND LABELING. NEC 110.3(B)
  
 4) LUMINAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED IN
 ACCORDANCE WITH THE PROVISIONS OF NEC 410.16(A) AND
 (B). REVISE PLANS TO INDICATE COMPLIANCE.
  
 5) METAL FRAMING MEMBERS SHALL BE BONDED TO THE
 EQUIPMENT GROUNDING CONDUCTOR FOR THE CIRCUIT THAT MAY
 ENERGIZE THE FRAMING AND BE SIZED IN ACCORDANCE WITH
 THE NEC TABLE 250.122. FOR THE PURPOSE OF THIS SECTION,
 A GROUNDED METAL OUTLET BOX ATTACHED TO THE FRAMING
 SHALL BE PERMITTED. FBC CHAPTER 27 SECTION 2704. REVISE
 PLANS TO INDICATE COMPLIANCE.
  
 6) ONE 125VOLT, SINGLE-PHASE, 15 OR 20AMP GFI
 RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
 LOCATION FOR THE SERVICING OF HEATING,
 AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE
 RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND
 WITHIN 25FT OF THE HEATING, AIR-CONDITIONING, AND
 REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET SHALL
 NOT BE CONNECTED TO THE LOAD SIDE OF THE EQUIPMENT
 DISCONNECTING MEANS. NEC 210.63 SEE ALSO 210.8(A)(3),
 AND 406.8(B)(1). REVISE PLANS TO INDICATE COMPLIANCE.
  
 7) INDICATE DISCONNECTS WHERE REQUIRED AT A/C EQUIPMENT
 ETC.. NEC 440.14. REVISE PLANS TO INDICATE COMPLIANCE.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-06-02 Cont ID  
Sent By dhayes Date 2014-06-02 Time 17:01 Rev Time 0.00
Received By dhayes Date 2014-06-02 Time 16:33 Sent To  
Notes
2014-06-02 17:39:20400 N. FLAGLER DR. PH-D2
  
 ELECTRICAL 1ST REVIEW
  
 ACTION: DENIED.
  
 CODE REFERENCED: 2008 EDITION OF THE NEC AND THE 2010
 EDITION OF THE FLORIDA BUILDING CODE.
  
 1) PROVIDE A LOAD CALCULATION. CIRCUITS HAVE BEEN
 ADDED. THIS AFFECTS THE TOTAL CONNECTED LOAD. THE PLAN
 INDICATES THE PANEL WILL BE CHANGED BUT NOT THE FEEDER.
 FBC 107.2.1
  
 2) PROVIDE AN EXISTING RISER DIAGRAM INDICATING THE
 EXISTING FEEDER TO THE NEW PANEL. PROVIDE WIRE TYPE AND
 SIZE. FBC 107.2.1
  
 3) IN KITCHENS, PANTRIES, BREAKFAST ROOMS, DINING
 ROOMS, AND SIMILAR AREAS OF DWELLING UNITS, RECEPTACLE
 OUTLETS FOR COUNTERTOP SPACES SHALL BE INSTALLED IN
 ACCORDANCE WITH NEC 210.52(C)(1) THROUGH (C)(5).
  
 4) RECEPTACLES SHALL BE SPACED SO THAT AT NO POINT
 ALONG THE FLOOR IN ANY WALL IS MORE THAN 6 FEET FROM A
 RECEPTACLE OUTLET. NEC 210.52 (A)(2).
  
 5) THE FLOOR PLAN SHALL INDICATE REQUIRED LIGHTING
 OUTLETS PER THE NEC 210.70
  
 6) RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED. AT
 LEAST 50% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHT
 FIXTURES SHALL BE HIGH EFFICIENCY. FBC-R 402.4.5, &
 404.1
  
 7) PROVIDE CUT SHEETS ON RECESSED LIGHTS TO INDICATE
 COMPLIANCE WITH THE NEC 110.3
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421.
 561-805-6717 OR [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2014-08-18 Cont ID  
Sent By pleduc Date 2014-08-18 Time   Rev Time 0.00
Received By pleduc Date 2014-08-18 Time 10:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-07-02 Cont ID  
Sent By PLEDUC Date 2014-07-02 Time   Rev Time 0.00
Received By pleduc Date 2014-07-02 Time 12:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-05-29 Cont ID  
Sent By pleduc Date 2014-05-09 Time   Rev Time 0.00
Received By pleduc Date 2014-05-09 Time 14:42 Sent To B
Notes
2014-05-09 14:54:50THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 THE RESULTS OF THE REMODELING MAY AFFECT THE FIRE
 SPRINKLER FIRE ALARM PROTECTION SYSTEMS. AN EVALUATION
 OF THESE SYSTEM SHALL BE COMPLETED BY CERTIFIED LIFE
 SAFETY CONTRACTORS. REQUIRED REVISIONS SHALL BE DONE
 UNDER SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY
 CONTRACTORS.
  
 A FIRE INSPECTOR SHALL VERIFY AND TEST THE LIFE SAFETY
 SYSTEMS ON INSPECTION.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-08-23 Cont ID  
Sent By jwitmer Date 2014-08-23 Time 10:47 Rev Time 0.00
Received By jwitmer Date 2014-08-14 Time 11:57 Sent To  
Notes
2014-08-15 11:57:57****EXPEDITED****
 B27
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-07-25 Cont ID  
Sent By jgomez Date 2014-07-25 Time 14:00 Rev Time 0.00
Received By jgomez Date 2014-07-01 Time 18:07 Sent To  
Notes
2014-07-01 18:07:49B27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-06-02 Cont ID  
Sent By dhayes Date 2014-06-02 Time 17:39 Rev Time 0.00
Received By dhayes Date 2014-05-06 Time 09:30 Sent To  
Notes
2014-05-07 09:33:03INCOMING SENT TO B02. JW

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2014-08-16 Cont ID  
Sent By hmoser Date 2014-08-16 Time 09:59 Rev Time 0.00
Received By hmoser Date 2014-08-16 Time 09:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2014-07-25 Cont ID  
Sent By HMOSER Date 2014-07-25 Time 11:04 Rev Time 0.00
Received By jgomez Date 2014-07-25 Time 11:04 Sent To  
Notes
2014-07-25 11:55:16RESIDENTIAL (R2) ALTERATION, MECHANICAL REVIEW
 COMMENTS.
 CODE: 2010 FBC
  
 1- THERE IS NO INFORMATION SUBMITTED SHOWING COMPLIANCE
 WITH THE BALANCED RETURN AIR SEC. 601.4 OF 2010
 FBC-MECHANICAL. PROVIDE INFORMATION SHOWING COMPLIANCE
 WITH THE BALANCED RETURN AIR IN ALL HABITABLE ROOMS.
  
 2- A) DUCT SIZE FEEDING THE MASTER BEDROOM, SITTING
 ROOM AND BEDROOM #2 WAS DOWN SIZED TO 28 X 4 AND 16 X 4
 RESPECTIVELY. PROVIDE CALCULATIONS SHOWING COMPLIANCE
 WITH SEC. 603.2 OF 2010 FBC-MECHANICAL FOR THE PROPOSED
 DUCT SIZE.
  
 B) SIZE OF REGISTERS SUPPLYING AIR TO THE MASTER
 BEDROOM, SITTING ROOM AND BEDROOM #2 ARE BIGGER THAN
 THE DUCT FEEDING THEM. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS SHOWING SUCH INSTALLATION. SEC.
 107.2.1.3 CITY AMENDMENTS TO FBC. ALSO, COORDINATE WITH
 ITEM #2(A) ABOVE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-05-27 Cont ID  
Sent By hmoser Date 2014-05-27 Time 09:37 Rev Time 0.00
Received By hmoser Date 2014-05-27 Time 09:26 Sent To  
Notes
2014-05-27 09:37:32PLAN DENIED
 1) PROVIDE EQUIPMENT SCHEDULE ON PLANS.
 PER 107 FBC. 2010
 2) PROVIDE EXHAUST FANS IN BATHROOMS
 PER TABLE 403.3 FBC (M) 2010
 3) REFER TO SECTION 601.4 BALANCED RETURN AIR
 2010 FBC (M)
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 3 Status P Date 2014-08-23 Cont ID  
Sent By jwitmer Date 2014-08-23 Time 10:46 Rev Time 0.00
Received By jwitmer Date 2014-08-23 Time 09:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2014-07-03 Cont ID  
Sent By JWITMER Date 2014-07-03 Time 07:01 Rev Time 0.00
Received By jwitmer Date 2014-07-03 Time 05:58 Sent To  
Notes
2014-07-03 07:01:29PLUMBING PLAN REVIEW
 PERMIT: 14050167
 ADD: 400 N FLAGLER DR # PH-D2
 CONT: MARYJULI CONSTRUCTION
 TEL: (561)386-6032
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. JULY 03/ 2014
 ACTION: DENIED
  
 1) SHEET # 3 THE GUEST BATH # 2 SHOWS A ISOMETRIC OF
 THE SANITARY, AS DRAWN WITH THE FIXTURE DRAINS ALL
 DRAINING INTO THE STACK. PLEASE NOTE THIS TYPE FITTING
 IS CALLED A COTTAGE TEE USED STRICKLY IN A R3
 RESIDENCE, EVEN THEN THE FIXTURES NEED TO BE VENTED,
 NOTE THIS PLAN DOES NOT SHOW VENTING FOR THE WATER
 CLOSET OR SHOWER. NOTE THIS IS A 3 PIPE DRAINAGE AND
 VENT PIPE SYSTEM, NOT A WASTE STACK VENT(GUT STACK) NOR
 IS THIS A ENGINEERED SOVENT SYSTEM.
  
 2) IN THE MASTER BATH THE PLANS INDICATE THE ROTATING
 OF THE WATERCLOSET, HOW WILL THE SANITARY PIPE BE MOVED
 IN THE FLOOR, HOW WILL THE FIRE RATING OF THE FLOOR BE
 PRESERVED.
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED. 2010 FBC-P 307.3
 PENETRATIONS OF FLOOR/CEILING ASSEMBLIES AND
 FIRE-RESISTANCE-RATED ASSEMBLIES. PENETRATIONS OF
 FLOOR/CEILING ASSEMBLIES AND ASSEMBLIES REQUIRED TO
 HAVE A FIRE-RESISTANCE RATING SHALL BE PROTECTED IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING.
  
 3) COMPLIED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-05-28 Cont ID  
Sent By jwitmer Date 2014-05-28 Time 06:31 Rev Time 0.00
Received By jwitmer Date 2014-05-28 Time 05:46 Sent To  
Notes
2014-05-28 06:21:56PLUMBING PLAN REVIEW
 PERMIT: 14050167
 ADD: 400 N FLAGLER DR # PH-D2
 CONT: MARYJULI CONSTRUCTION
 TEL: (561)386-6032
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. MAY 27/ 2014
 ACTION: DENIED
  
 1) THERE HAVE BEEN NO PLUMBING SHEETS PROVIDED, THE
 GUEST BATH # 2 PLEASE SHOW THE LOCATION OF THE VENT FOR
 THE NEWLY PLACED VANITY, DISTANCE FROM TRAP TO VENT,
 2010 FBC-P TABLE 906.1.
  
 2) IN THE MASTER BATH THE PLANS INDICATE THE ROTATING
 OF THE WATERCLOSET, HOW WILL THE SANITARY PIPE BE MOVED
 IN THE FLOOR, HOW WILL THE FIRE RATING OF THE FLOOR BE
 PRESERVED.
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED. 2010 FBC-P 307.3
 PENETRATIONS OF FLOOR/CEILING ASSEMBLIES AND
 FIRE-RESISTANCE-RATED ASSEMBLIES. PENETRATIONS OF
 FLOOR/CEILING ASSEMBLIES AND ASSEMBLIES REQUIRED TO
 HAVE A FIRE-RESISTANCE RATING SHALL BE PROTECTED IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING.
  
 3) PLEASE PROVIDE THE VENT LOCATION OF THE KITCHEN SINK
 AND THE DITANCE FROM THE TRAP 2010 FBC-P TABLE 906.1.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  