Plan Review Details - Permit 14041084
Plan Review Stops For Permit 14041084
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-06-26 Cont ID  
Sent By jwitmer Date 2014-06-26 Time 15:46 Rev Time 0.00
Received By jwitmer Date 2014-06-26 Time 15:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-05-22 Cont ID  
Sent By jwitmer Date 2014-05-22 Time 15:56 Rev Time 0.00
Received By jwitmer Date 2014-05-22 Time 15:41 Sent To  
Notes
2014-05-22 15:56:24BUILDING PLAN REVIEW
 PERMIT: 14041084
 ADD: 4335 N HAVERHILL RD
 CONT:LENNAR HOMES, LLC
 TEL: (954)533-5299X1
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. MAY 22/ 2014
 ACTION: DENIED
  
 1) STATE APPROVED PLANS INDICATE SITE INSTALLED ITEMS:
 1A) STORM SHUTTERS
 1B) ACCESSIBLE STAIRS AND RAMPS
  
 2) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(E) SHUTTERS
  
 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 4) PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.4.
 FL BLD CODE 2004 SECTION 106.3.3, 1609.1.4, 1714.5.1 &
 EXIST BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE
 INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING
 SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT
 SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS,
 WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION TO FACILITATE
 PLAN REVIEW AND PERMIT ISSUANCE.
  
 5) 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE:
 STAIRS CONSTRUCTION/GEOMETRY/ HANDRAILS/ GAURDRAILS
 10. ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE
 FOLLOWING: RAMPS/ HANDRAILS & GAURDRAILS.
 SITE REQUIREMENTS, ACCESSIBLE ROUTE & VERTICAL
 ACCESSIBILITY
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2014-05-29 Cont ID  
Sent By dhayes Date 2014-05-29 Time 12:31 Rev Time 0.00
Received By dhayes Date 2014-05-29 Time 12:31 Sent To  
Notes
2014-05-29 12:36:57ELECTRICAL NOT REQUIRED AT THIS TIME. THIS IS A STATE
 APROVED MODULAR BUILDING REQUIRING ONLY A FEEDER TO THE
 PANELS. THERE IS A SUPLEMENTAL PERMIT APPLICATION TO
 FOLLOW INCLUDING THE ELECTRICAL RISER DIAGRAM TO FEED
 THE PANELS.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR AT [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-06-12 Cont ID  
Sent By skennedy Date 2014-06-12 Time 08:43 Rev Time 0.00
Received By skennedy Date 2014-06-12 Time 08:43 Sent To  
Notes
2014-06-12 08:43:45REVIEW BY PLEDUC.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2014-05-29 Cont ID  
Sent By skennedy Date 2014-05-29 Time 10:24 Rev Time 0.00
Received By skennedy Date 2014-05-22 Time 10:24 Sent To  
Notes
2014-05-29 10:26:14REVIEW BY PML:
  
 5/22/14 FAILED BY FIRE PREVENTION, NO SITE PLAN OR ADA
 STEPS OR RAMPS, PML
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-05-29 Cont ID  
Sent By dhayes Date 2014-05-29 Time 12:31 Rev Time 0.00
Received By dhayes Date 2014-05-01 Time 05:38 Sent To  
Notes
2014-05-01 05:38:55INCOMING C07. JW

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-05-22 Cont ID  
Sent By jwitmer Date 2014-05-22 Time 15:41 Rev Time 0.00
Received By jwitmer Date 2014-05-22 Time 15:40 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2014-05-21 Cont ID  
Sent By avann Date 2014-05-21 Time 11:12 Rev Time 0.00
Received By ajones Date 2014-05-21 Time 11:12 Sent To B
Notes
2014-05-21 11:14:105/21/14- APPROVED FOR SALES TRAILER ONLY. A SEPERATE
 LANDSCAPE AND PARKING LOT PERMIT WILL BE REQUIRED.
  
 ANGELLA VANN
 [email protected]
 561-822-1441
2014-05-06 14:43:285/6/14