Plan Review Details - Permit 14040680
Plan Review Stops For Permit 14040680
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-04-29 Cont ID  
Sent By jwitmer Date 2014-04-29 Time 08:51 Rev Time 0.00
Received By jwitmer Date 2014-04-29 Time 08:00 Sent To  
Notes
2014-04-29 08:12:41BUILDING PROVISO:
 1) BEFORE THE INSTALLATION OF FLOOR INSULATION SUBMIT
 MANUFACTURERS TEST FOR COMPLIANCE WITH:
 1A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
 1B) FBC-B 2010 603.2 EXCEPTION (1) TILE FLOORING
 FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
  
  
  
 FBC-B 2010
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-04-21 Cont ID  
Sent By rlecky Date 2014-04-21 Time 13:07 Rev Time 0.00
Received By rlecky Date 2014-04-21 Time 12:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-04-29 Cont ID  
Sent By jwitmer Date 2014-04-29 Time 08:52 Rev Time 0.00
Received By jwitmer Date 2014-04-18 Time 16:56 Sent To  
Notes
2014-04-18 16:56:38INCOMING SENT TO B23 BOX. JW

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-04-29 Cont ID  
Sent By jwitmer Date 2014-04-29 Time 08:51 Rev Time 0.00
Received By jwitmer Date 2014-04-29 Time 08:37 Sent To  
Notes
2014-04-29 08:51:36MECHANICAL PROVISO;
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 COMMERCIAL BUILDINGS:
 MECHANICAL
 BATHROOM VENTILATION IT APPEARS THE CEILING FAN IS
 BEING REMOVED.
 ENVIRONMENTAL AIR. AIR THAT IS CONVEYED TO OR FROM
 OCCUPIED AREAS THROUGH DUCTS WHICH ARE NOT PART OF THE
 HEATING OR AIR-CONDITIONING SYSTEM, SUCH AS VENTILATION
 FOR HUMAN USAGE, DOMESTIC KITCHEN RANGE EXHAUST,
 BATHROOM EXHAUST AND DOMESTIC CLOTHES DRYER EXHAUST.
  
 2010 FBC-MECHANICAL TABLE 403.3 EXHAUST AIRFLOW 50 CFM

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-04-29 Cont ID  
Sent By jwitmer Date 2014-04-29 Time 08:36 Rev Time 0.00
Received By jwitmer Date 2014-04-29 Time 08:10 Sent To  
Notes
2014-04-29 08:22:44PLUMBING PROVISO;
 SHOWER LINER TEST REQUIRED.
 312.9 SHOWER LINER TEST.
 WHERE SHOWER FLOORS AND RECEPTORS ARE MADE WATER-TIGHT
 BY THE APPLICATION OF MATERIALS REQUIRED BY SECTION
 417.5.2, THE COMPLETED LINER INSTALLATION SHALL BE
 TESTED. THE PIPE FROM THE SHOWER DRAIN SHALL BE PLUGGED
 WATER TIGHT FOR THE TEST. THE FLOOR AND RECEPTOR AREA
 SHALL BE FILLED WITH POTABLE WATER TO A DEPTH OF NOT
 LESS THAN 2 INCHES (51 MM) MEASURED AT THE THRESHOLD.
 WHERE A THRESHOLD OF AT LEAST 2 INCHES (51 MM) HIGH
 DOES NOT EXIST, A TEMPORARY THRESHOLD SHALL BE
 CONSTRUCTED TO RETAIN THE TEST WATER IN THE LINED FLOOR
 OR RECEPTOR AREA TO A LEVEL NOT LESS THAN 2 INCHES (51
 MM) DEEP MEASURED AT THE THRESHOLD. THE WATER SHALL BE
 RETAINED FOR A TEST PERIOD OF NOT LESS THAN 15 MINUTES,
 AND THERE SHALL NOT BE EVIDENCE OF LEAKAGE.

Review Stop Z ZONING
Rev No 1 Status P Date 2014-04-21 Cont ID  
Sent By ajones Date 2014-04-21 Time 15:17 Rev Time 0.00
Received By ajones Date 2014-04-21 Time 15:17 Sent To  
Notes
***NONE***