Plan Review Details - Permit 14040504
Plan Review Stops For Permit 14040504
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By jwitmer Date 2014-05-30 Time 12:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-04-29 Cont ID  
Sent By jwitmer Date 2014-04-29 Time 16:43 Rev Time 0.00
Received By jwitmer Date 2014-04-29 Time 14:29 Sent To  
Notes
2014-04-29 16:43:36BUILDING PLAN REVIEW
 PERMIT: 14040504
 ADD: 207 CLEMATIS ST.
 CONT: GEORGE FRAKER
 TEL: (561)502-4699
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUESDAY APRIL 29/ 2014
 ACTION: DENIED
  
 1) SHEET # 1 THE FRONT ELEVATION SHOWS THE USE OF A
 22'-0" LONG HORIZONTAL MULLION. THE PRODUCT APPROVAL
 SUBMITTED NOA 11-0922.01
 LONGEST SPAN OF 13.33 FT OR 160 INCHES. PLEASE PROVIDE
 A STRUCTURAL ELEMENT THAT WILL BE ABLE TO CARRY THE
 LOADS FOR THE 22'-0" SPAN.
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING,
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS, MULLIONS
  
 2) SHEET # 1 INDICATES IN THE NOTES THE INSTALATION OF
 EUROWALL FOLDING DOOR SYSTEM, NO PRODUCT APPROVAL WAS
 SUBMITTED FOR THIS REVIEW.
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING,
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
  
 3) SHEET # 1 APPEARS TO BE A OUTSWING DOOR SYSTEM,
 PLEASE PROVIDE WHERE THE PROPERTY LINE IS LOCATED SHOW
 COMPLIANCE WITH :
 2010 FBC-B 202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8
 FEET IN HEIGHT.
 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY ABOVE GRADE
 AND BELOW 8 FEET (2438 MM) IN HEIGHT SHALL BE
 PROHIBITED EXCEPT AS PROVIDED FOR IN SECTIONS 3202.2.1
 THROUGH 3202.2.3. DOORS AND WINDOWS SHALL NOT OPEN OR
 PROJECT INTO THE PUBLIC RIGHT-OF-WAY.
  
 4) NOTE MOST OUTSWING DOOR SYSTEMS ARE NOT PART OF A
 EGRESS SYSTEM, SINCE WHEN THE DOOR SYSTEM IS CLOSED THE
 ENTRY DOOR IS A SWING DOOR, BUT THERE IS USUALLY A
 BOTTOM TRACK, PLEASE PROVIDE DETAILS THAT WILL COMPLY
 WITH 2010 FL ACCESSIBILITY CODE:
 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
 404.2.4.4 FLOOR OR GROUND SURFACE. FLOOR OR GROUND
 SURFACE WITHIN REQUIRED MANEUVERING CLEARANCES SHALL
 COMPLY WITH 302. CHANGES IN LEVEL ARE NOT PERMITTED.
 EXCEPTIONS:
 1. SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED.
 2. CHANGES IN LEVEL AT THRESHOLDS COMPLYING WITH
 404.2.5 SHALL BE PERMITTED.
 404.2.5 THRESHOLDS.
 THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH
 (13 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN
 LEVEL AT DOORWAYS SHALL COMPLY WITH 302 AND 303.
  
 5) SHEET # 1 ALSO HAS A DETAIL OF NEW ACOUSTICAL
 CEILING SYSTEM. THE PLANS INDICATE SEE MANUFACTURERS
 INSTRUCTIONS FOR DETAILS. NO LITERATURE HAS BEEN
 SUVMITTED. PLEASE PROVIDE CODE COMPLIANCE WITH 2010
 FBC-B:
 808.1 ACOUSTICAL CEILING SYSTEMS.
 THE QUALITY, DESIGN, FABRICATION AND ERECTION OF METAL
 SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY-IN PANEL
 CEILINGS IN BUILDINGS OR STRUCTURES SHALL CONFORM WITH
 GENERALLY ACCEPTED ENGINEERING PRACTICE, THE PROVISIONS
 OF THIS CHAPTER AND OTHER APPLICABLE REQUIREMENTS OF
 THIS CODE.
  
 808.1.1 MATERIALS AND INSTALLATION.
 ACOUSTICAL MATERIALS COMPLYING WITH THE INTERIOR FINISH
 REQUIREMENTS OF SECTION 803 SHALL BE INSTALLED IN
 ACCORDANCE WITH THE MANUFACTURER?S RECOMMENDATIONS AND
 APPLICABLE PROVISIONS FOR APPLYING INTERIOR FINISH.
  
 808.1.1.1 SUSPENDED ACOUSTICAL CEILINGS.
 SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE INSTALLED
 IN ACCORDANCE WITH THE PROVISIONS OF ASTM C 635 AND
 ASTM C 636.
  
 : WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-05-01 Cont ID  
Sent By rlecky Date 2014-05-01 Time 12:55 Rev Time 0.00
Received By rlecky Date 2014-05-01 Time 12:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-04-22 Cont ID  
Sent By pleduc Date 2014-04-22 Time 12:23 Rev Time 0.00
Received By pleduc Date 2014-04-22 Time 12:14 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-06-02 Cont ID  
Sent By jlmitch Date 2014-06-02 Time 11:07 Rev Time 0.00
Received By jlmitch Date 2014-05-19 Time 08:52 Sent To Z
Notes
2014-05-30 11:30:06APPLICANT ASK TO ROUTE THE PERMIT TO JIM WITMER BEFORE
 FIRE.
2014-05-19 08:53:56SENT TO AAPONTE, ANNA, ROUTE TO FIRE BOX WHEN COMPLETE.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-05-12 Cont ID  
Sent By skennedy Date 2014-05-12 Time 13:39 Rev Time 0.00
Received By skennedy Date 2014-04-15 Time 06:39 Sent To  
Notes
2014-05-12 13:29:29TO STEVEN.
2014-04-15 06:39:51INCOMING SENT TO C14 BOX. JW

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-05-02 Cont ID  
Sent By hmoser Date 2014-05-02 Time 15:25 Rev Time 0.00
Received By hmoser Date 2014-05-02 Time 15:11 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2014-05-30 Cont ID  
Sent By jlmitch Date 2014-06-02 Time 11:08 Rev Time 0.00
Received By aaponte Date 2014-05-30 Time 11:28 Sent To  
Notes
2014-05-30 11:29:04PROVISO:NO MODIFICATION CAN BE DONE TO EXISTING
 SIDEWALK ON CLEMATIS STREET.

Review Stop Z ZONING
Rev No 1 Status F Date 2014-05-12 Cont ID  
Sent By aaponte Date 2014-05-12 Time 13:26 Rev Time 0.00
Received By aaponte Date 2014-05-12 Time 13:23 Sent To  
Notes
2014-05-19 15:45:015/19/14 ZONING RECEIVED, SENT TO AA. SG
2014-05-12 13:29:05PLEASE PROVIDE A SURVEY INDICATING THE LOCATION OF THE
 PROPERTY LINE.
 PLEASE PROVIDE INFORMATION INDICATING THE LOCATION OF
 THE PROPOSED FOLDING DOORS IN RELATION TO THE PROPERTY
 LINE. DOORS ARE NOT ALLOWED TO ENCROACH INTO THE ROW.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.