Plan Review Details - Permit 14030898
Plan Review Stops For Permit 14030898
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-05-23 Cont ID  
Sent By jgomez Date 2014-05-23 Time 17:26 Rev Time 0.00
Received By jgomez Date 2014-05-23 Time 17:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-04-21 Cont ID  
Sent By jgomez Date 2014-04-21 Time 09:38 Rev Time 0.00
Received By jgomez Date 2014-04-21 Time 09:11 Sent To  
Notes
2014-04-21 09:58:00SIGN, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- ENGINEER TO PROVIDE ORIGINAL SEAL AND SIGNATURE AS
 REQUIRED BY CHAPTER 471 FLORIDA STATUTE. DIGITAL
 SIGNATURE APPLIES ONLY TO DIGITALLY SUBMITTED DOCUMENTS
 NOT FOR HARD COPIES.
  
 2- A) ENGINEER TO SPECIFY CURRENT BUILDING CODE AND ALL
 THE DESIGN CRITERIA (INCLUDING THE WIND LOAD AND
 BUILDING EXPOSURE) AS REQUIRED BY SEC. 1603 AND SEC.
 1609 OF 2010 FBC
  
 B) PLANS SUBMITTED ONLY PROVIDE INFORMATION FOR THE 18"
 LETTERS. ENGINEER TO PROVIDE COMPLETE INFORMATION FOR
 THE CONSTRUCTION AND INSTALLATION OF THE 6" LETTERS.
 THERE IS NO INFORMATION GIVEN. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. UPDATE VALUATION TO INCLUDE ALL THE LABOR,
 MATERIALS, CONTRACTOR'S OVERHEAD AND PROFIT AND THE
 DESIGN PROFESSIONAL FEES. SEC. 109.3 CITY AMENDMENTS TO
 FBC.
  
 4- NOTICE OF COMMENCEMENT WILL BE REQUIRED BY CHAPTER
 713 FLORIDA STATUTE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)8-05-6712
2014-04-18 14:04:55ON JG DESK

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-04-16 Cont ID  
Sent By dhayes Date 2014-04-16 Time 13:59 Rev Time 0.00
Received By dhayes Date 2014-04-16 Time 13:59 Sent To B
Notes
2014-04-16 14:00:20ROUTED TO BUILDING <5K

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-05-23 Cont ID  
Sent By jgomez Date 2014-05-23 Time 17:58 Rev Time 0.00
Received By jgomez Date 2014-05-08 Time   Sent To  
Notes
2014-05-08 10:09:11SENT TO ZONING ES.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-04-21 Cont ID  
Sent By jgomez Date 2014-04-21 Time 09:11 Rev Time 0.00
Received By jgomez Date 2014-03-21 Time 14:24 Sent To  
Notes
2014-03-21 14:25:02ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2014-05-22 Cont ID  
Sent By ESchneid Date 2014-05-22 Time 13:59 Rev Time 0.50
Received By eschneid Date 2014-05-22 Time 13:59 Sent To B
Notes
2014-05-22 14:16:46PASSED
  
 PERMITTED: 18.5 SQ. FT.
 PROPOSED: 10.75 SQ. FT.
  
  
  
2014-05-08 12:27:395/8/14 ZONING RECEIVED, SENT TO ES. SG

Review Stop Z ZONING
Rev No 1 Status F Date 2014-04-07 Cont ID  
Sent By ESchneid Date 2014-04-07 Time 14:55 Rev Time 0.50
Received By eschneid Date 2014-03-21 Time 14:27 Sent To E
Notes
2014-04-07 15:14:48FAILED
  
 1) THE TOTAL SIGN AREA WAS NOT PROVIDED. THE AREA
 BETWEEN THE BOTTOM OF THE "4D" AND THE TOP OF THE
 "GELATO & ITALIAN GOURMET" NEEDS TO BE PROVIDED AND IS
 COUNTED AS SIGN AREA. NOTE IT APPEARS THAT THE SIGN
 WILL NOT EXCEED THE ALLOWED SIGN AREA ONCE IT IS
 COUNTED.
  
 PERMITTED: 18.5 SQ. FT.
 PROPOSED: ?? SQ. FT.
  
 2) THE CITYPLACE MASTER SIGN PLAN LIMITS THE SIGN COPY
 TO TRADE NAMES AND LOGOS ONLY, UNLESS CITYPLACE
 APPROVES, IN WRITING, AN ADMINISTRATIVE VARIANCE TO
 ALLOW THE ADDITIONAL TEXT. EITHER PROVIDE VERIFICATION
 THAT THE BUSINESS NAME IS 4D GELATO & ITALIAN GOURMET,
 (THERE IS NO BUSINESS TAX RECEIPT ON RECORD WITH CITY
 WITH THIS NAME NOR WAS THE FULL TEXT SHOWN WHEN A WEB
 SEARCH WAS CONDUCTED), OR PROVIDE THE APPROVAL FROM
 CITYPLACE.
  
 A COPY OF THESE COMMENTS HAS BEEN SENT TO CARLOS BERNAL
 AT CITYPLACE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2014-03-21 14:27:153/21/14 ZONING RECEIVED, SENT TO ES. SG


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved