Plan Review Details - Permit 14030818
Plan Review Stops For Permit 14030818 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2015-04-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-04-25 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-04-25 |
Time |
13:30 |
Sent To |
|
|
Notes |
2015-04-01 09:17:44 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2014-12-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-12-08 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-12-07 |
Time |
11:20 |
Sent To |
|
|
Notes |
2014-12-08 12:14:00 | BUILDING PLAN REVIEW | | PERMIT: 14030818 | | ADD: 526 CLEMATIS ST 1ST FLOOR & 2ND FLOOR- CHANGE OF | | OCCUPANY/INTERIOR & EXTERIOR | | CONT: JM PROPERTIES OF WEST PALM BEACH, INC | | TEL: (561)756-5744 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | BLDG TYPE III-B SPRINKLERED | | | | 3RD REVIEW | | DATE: MON. DEC. 08/ 2014 | | ACTION: BUILDING PROVISO | | BUILDING APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | THE LAST RENOVATIONS TO THIS BUILDING UNDER PERMIT | | 03060274, FIRST FLOOR MERCANTILE AND THE 2ND FLOOR R2 | | APARTMENTS, THIS REVIEW WILL BE CONSIDERED A CHANGE IN | | OCCUPANCY AND CHAPTER 9 OF THE EXISITNG BUILDING CODE. | | 901.3 CHANGE OF OCCUPANCY CLASSIFICATION. | | WHERE THE OCCUPANCY CLASSIFICATION OF A BUILDING | | CHANGES, THE PROVISIONS OF SECTIONS 902 THROUGH 912 | | SHALL APPLY. THIS INCLUDES A CHANGE OF OCCUPANCY | | CLASSIFICATION WITHIN A GROUP AS WELL AS A CHANGE OF | | OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A DIFFERENT | | GROUP. | | | | | | CONTRACTOR IS PROCEEDING AT THEIR OWN RISK!!! 2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, ADMINISTRATION, 105.13 PHASED PERMIT | | APPROVAL. AFTER SUBMITTAL OF THE APPROPRIATE | | CONSTRUCTION DOCUMENTS, THE BUILDING OFFICIAL IS | | AUTHORIZED TO ISSUE A PERMIT FOR THE CONSTRUCTION OF | | FOUNDATIONS OR ANY OTHER PART OF A BUILDING OR | | STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS FOR THE | | WHOLE BUILDING OR STRUCTURE HAVE BEEN SUBMITTED. THE | | HOLDER OF SUCH PERMIT FOR THE FOUNDATION OR OTHER PARTS | | OF A BUILDING OR STRUCTURE SHALL PROCEED AT THE | | HOLDER?S OWN RISK WITH THE BUILDING OPERATION AND | | WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | 1) REVISION REQUIRED. AN ARCHITECTURAL SHEET IS | | REQUIRED SHOWING THE SCHEMATIC LAYOUT FOR THE FIRE | | SPRINKLERS, A FULL NFPA 13 SYSTEM WILL BE REQUIRED. | | A HOLD WILL BE PUT ON THE CERTIFICATE OF OCCUPANCY | | UNTIL THIS REVISION IS SUBMITTED AND APPROVED. SEPARATE | | FIRE SPRINKLER PLANS WILL ALSO NEED TO BE SUBMITTED BY | | THE ENGINEER OF RECORD AND REVIEWED BY THE DESIGNER OF | | RECORD WITH THIER SHOP DRAWING STAMP OF APPROVAL, | | APPROVED OR APPROVED WITH COMMENTS. | | | | 107.2.1.1 FIRE PROTECTION SYSTEM SHOP DRAWINGS. SHOP | | DRAWINGS FOR THE FIRE PROTECTION SYSTEM(S) SHALL BE | | SUBMITTED TO INDICATE CONFORMANCE WITH THIS CODE AND | | THE CONSTRUCTION DOCUMENTS AND SHALL BE APPROVED PRIOR | | TO THE START OF SYSTEM INSTALLATION. SHOP DRAWINGS | | SHALL CONTAIN ALL INFORMATION AS REQUIRED BY THE | | REFERENCED INSTALLATION STANDARDS IN CHAPTER 9. | | | | 3RD REQUEST. MON. DEC. 08/2014 2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION,107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | BUILDINGS. | | 107.3.5.1 COMMERCIAL BUILDINGS: | | 107.3.5.1.1 BUILDING | | (5) FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: | | SCHEMATIC FIRE SPRINKLERS | | STANDPIPES | | PRE-ENGINEERED SYSTEMS | | | | THE COVERSHEET A0.0 INDICATES THIS BUILDING TO BE FIRE | | SPRINKLERED, BUT THERE IS NO MENTION OF A FIRE | | SPRINKLER PLAN IN THE INDEX OF DRAWINGS NOR ANYWHERE | | ELSE IN THE PLANS. TRAVEL DISTANCES ARE SHOWN FOR | | NON-SPRINKLERED BUILDING. | | 2010 EXST BLDG CODE 904.1 GENERAL. | | FIRE PROTECTION REQUIREMENTS OF SECTION 912 SHALL APPLY | | WHERE A BUILDING OR PORTIONS THEREOF UNDERGO A CHANGE | | OF OCCUPANCY CLASSIFICATION. | | 912.2 FIRE PROTECTION SYSTEMS. | | FIRE PROTECTION SYSTEMS SHALL BE PROVIDED IN ACCORDANCE | | WITH SECTIONS 912.2.1 AND 912.2.2. | | | | EXST BLDG CODE 912.2.1 FIRE SPRINKLER SYSTEM. | | WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT | | REQUIRES AN AUTOMATIC FIRE SPRINKLER SYSTEM TO BE | | PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH | | CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH | | SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE | | CHANGE OF OCCUPANCY OCCURS. | | | | 2010 FBC-B F] 903.2.1.2 GROUP A-2. | | AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED FOR | | GROUP A-2 OCCUPANCIES WHERE ONE OF THE FOLLOWING | | CONDITIONS EXISTS: | | 1. THE FIRE AREA EXCEEDS 5,000 SQUARE FEET (464.5 M2); | | 2. THE FIRE AREA HAS AN OCCUPANT LOAD OF 100 OR MORE; | | | | EXST BLDG CODE 912.2.2 FIRE ALARM AND DETECTION SYSTEM. | | WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT | | REQUIRES A FIRE ALARM AND DETECTION SYSTEM TO BE | | PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH | | CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH | | SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE | | CHANGE OF OCCUPANCY OCCURS. EXISTING ALARM NOTIFICATION | | APPLIANCES SHALL BE AUTOMATICALLY ACTIVATED THROUGHOUT | | THE BUILDING. WHERE THE BUILDING IS NOT EQUIPPED WITH A | | FIRE ALARM SYSTEM, ALARM NOTIFICATION APPLIANCES SHALL | | BE PROVIDED THROUGHOUT THE AREA WHERE THE CHANGE OF | | OCCUPANCY OCCURS AND SHALL BE AUTOMATICALLY ACTIVATED. | | | | BUILDING PROVISO: | | 10C) FRONT ENTRY REDESIGN: | | 10C)(1) MISSING PRODUCT APPROVALS 2010 FBC-B 1609.1.2 | | PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS & | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS:(31)(A) EXTERIOR DOORS. | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-10-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-10-08 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-10-08 |
Time |
06:04 |
Sent To |
|
|
Notes |
2014-10-08 08:15:40 | BUILDING PLAN REVIEW | | PERMIT: 14030818 | | ADD: 526 CLEMATIS ST 1ST FLOOR & 2ND FLOOR- CHANGE OF | | OCCUPANY/INTERIOR & EXTERIOR | | CONT: JM PROPERTIES OF WEST PALM BEACH, INC | | TEL: (561)756-5744 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | BLDG TYPE III-B SPRINKLERED | | | | 2ND REVIEW | | DATE: WEDNESDAY 08/ 2014 | | ACTION: DENIED | | | | THE LAST RENOVATIONS TO THIS BUILDING UNDER PERMIT | | 03060274, FIRST FLOOR MERCANTILE AND THE 2ND FLOOR R2 | | APARTMENTS, THIS REVIEW WILL BE CONSIDERED A CHANGE IN | | OCCUPANCY AND CHAPTER 9 OF THE EXISITNG BUILDING CODE. | | 901.3 CHANGE OF OCCUPANCY CLASSIFICATION. | | WHERE THE OCCUPANCY CLASSIFICATION OF A BUILDING | | CHANGES, THE PROVISIONS OF SECTIONS 902 THROUGH 912 | | SHALL APPLY. THIS INCLUDES A CHANGE OF OCCUPANCY | | CLASSIFICATION WITHIN A GROUP AS WELL AS A CHANGE OF | | OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A DIFFERENT | | GROUP. | | | | 1) THE COVERSHEET A0.0 INDICATES THE OCCUPANCY AS A A2 | | NIGHTCLUB SINCE THERE IS NO KITCHEN SHOWN ON THE PLANS. | | SHEET A1.2 LIST OCCUPANT LOADS FOR EACH FLOOR EXAMPLE | | THE 2ND FLOOR LIST CUSTOMER AREA 992 SQ. FT./ 198 | | OCCUPANTS + 32 +16+ 8 +6 +10. PLEASE PROVIDE WHERE THE | | ADDITIONAL | | OCCUPANT LOADS ARE TAKEN FROM, INDICATE THE AREA AND | | LOADING FACTOR. | | 2010 FBC-B 1004.2 INCREASED OCCUPANT LOAD. | | THE OCCUPANT LOAD PERMITTED IN ANY BUILDING, OR PORTION | | THEREOF, IS PERMITTED TO BE INCREASED FROM THAT NUMBER | | ESTABLISHED FOR THE OCCUPANCIES IN TABLE 1004.1.1, | | PROVIDED THAT ALL OTHER REQUIREMENTS OF THE CODE ARE | | ALSO MET BASED ON SUCH MODIFIED NUMBER AND THE OCCUPANT | | LOAD DOES NOT EXCEED ONE OCCUPANT PER 7 SQUARE FEET | | (0.65 M2) OF OCCUPIABLE FLOOR SPACE. WHERE REQUIRED BY | | THE BUILDING OFFICIAL, AN APPROVED AISLE, SEATING OR | | FIXED EQUIPMENT DIAGRAM SUBSTANTIATING ANY INCREASE IN | | OCCUPANT LOAD SHALL BE SUBMITTED. WHERE REQUIRED BY THE | | BUILDING OFFICIAL, SUCH DIAGRAM SHALL BE POSTED. | | | | 2) 2ND REQUEST. 2010 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION,107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | BUILDINGS. | | 107.3.5.1 COMMERCIAL BUILDINGS: | | 107.3.5.1.1 BUILDING | | (5) FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: | | SCHEMATIC FIRE SPRINKLERS | | STANDPIPES | | PRE-ENGINEERED SYSTEMS | | | | THE COVERSHEET A0.0 INDICATES THIS BUILDING TO BE FIRE | | SPRINKLERED, BUT THERE IS NO MENTION OF A FIRE | | SPRINKLER PLAN IN THE INDEX OF DRAWINGS NOR ANYWHERE | | ELSE IN THE PLANS. TRAVEL DISTANCES ARE SHOWN FOR | | NON-SPRINKLERED BUILDING. | | 2010 EXST BLDG CODE 904.1 GENERAL. | | FIRE PROTECTION REQUIREMENTS OF SECTION 912 SHALL APPLY | | WHERE A BUILDING OR PORTIONS THEREOF UNDERGO A CHANGE | | OF OCCUPANCY CLASSIFICATION. | | 912.2 FIRE PROTECTION SYSTEMS. | | FIRE PROTECTION SYSTEMS SHALL BE PROVIDED IN ACCORDANCE | | WITH SECTIONS 912.2.1 AND 912.2.2. | | | | EXST BLDG CODE 912.2.1 FIRE SPRINKLER SYSTEM. | | WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT | | REQUIRES AN AUTOMATIC FIRE SPRINKLER SYSTEM TO BE | | PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH | | CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH | | SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE | | CHANGE OF OCCUPANCY OCCURS. | | | | 2010 FBC-B F] 903.2.1.2 GROUP A-2. | | AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED FOR | | GROUP A-2 OCCUPANCIES WHERE ONE OF THE FOLLOWING | | CONDITIONS EXISTS: | | 1. THE FIRE AREA EXCEEDS 5,000 SQUARE FEET (464.5 M2); | | 2. THE FIRE AREA HAS AN OCCUPANT LOAD OF 100 OR MORE; | | | | EXST BLDG CODE 912.2.2 FIRE ALARM AND DETECTION SYSTEM. | | WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT | | REQUIRES A FIRE ALARM AND DETECTION SYSTEM TO BE | | PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH | | CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH | | SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE | | CHANGE OF OCCUPANCY OCCURS. EXISTING ALARM NOTIFICATION | | APPLIANCES SHALL BE AUTOMATICALLY ACTIVATED THROUGHOUT | | THE BUILDING. WHERE THE BUILDING IS NOT EQUIPPED WITH A | | FIRE ALARM SYSTEM, ALARM NOTIFICATION APPLIANCES SHALL | | BE PROVIDED THROUGHOUT THE AREA WHERE THE CHANGE OF | | OCCUPANCY OCCURS AND SHALL BE AUTOMATICALLY ACTIVATED. | | | | 3) COMPLIED, NEW INSWING FOLDING DOOR SYSTEM SHOWN ON | | PLANS. | | | | | | 4) SEMI-COMPLIED. THE (2) EXISTING SWING DOORS NEED TO | | SHOW THEY DO NOT SWING OUT OVER THE PROPERTY LINE AND | | IN COMPLIANCE WITH 2010 FBC-B | | 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN | | HEIGHT. PROVIDE A SITE PLAN AND OR SURVEY SHOWING CODE | | COMPLIANCE. | | | | 5) 2ND REQUEST. THE PLANS DO NOT HAVE ANY DETAILS AS | | FAR AS THE SILL FOR THE FOLDING DOOR SYSTEM, PLEASE | | PROVIDE COMPLIANCE WITH 2010 FL ACCESS CODE 404.2.5 | | THRESHOLDS. | | THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH | | (13 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN | | LEVEL AT DOORWAYS SHALL COMPLY WITH 302 AND 303. | | | | 6) SEMI-COMPLIED. SHEET A1.1 THE FRONT STAIR IS AN | | UNENCLOSED EXIT STAIRWAY AND TAKING THE EXEMPTION# 3 IN | | SECTION 1016.1. PLEASE PROVIDE THE WIDTH BOTH STAIRS | | AND THE ALLOWABLE OCCUPANT LOADS EACH STAIR WILL | | ACCEPT. 2010 FBC-B 1005.1. | | | | 7) SHEET A1.1 THE ELEVATOR MACHINE ROOM 2010 FBC-B | | 3006.4. PLEASE NOTE THE CEILING OF THIS ROOM WILL NEED | | TO BE FIRE RATED AS WELL IT WILL ABUT THE FRAMING | | MEMBERS OF THE STAIRWELL. 2010 FBC-B 1022.1 & 707 | | HORIZONTAL ASSEMBLIES. DOOR RATING 3/4 HR FIRE BARRIER | | TABLE 715.4. | | | | 8-9) COMPLIED. | | | | 10) STRUCTURAL SHEET S-1: | | | | 10A) STRUCTURAL SHEET ELEVATOR DETAIL IS MISSING THE | | FOLLOWING : | | 10A)(1) TB- HEIGTH NOT PROVIDED. NOTE TO MATCH | | EXISTING, NOTE THIS IS A (2) STORY SHAFT AND THERE IS | | NO DETAIL AS TO HOW THE TOP OF THE SHAFT FINISHES, | | BELOW THE ROOF OR ABOVE THE ROOF. 2010 FBC-B 708.12 | | 10A)(2) COMPLIED. | | 10A)(3) ELEVATOR DOES NOT SHOW A PIT OR RECESS FOR THE | | FLOOR OF THE ELEVATOR CAB TO BE LEVEL WITH THE FLOOR. | | 10)(4) THE ELEVATOR SHAFT DOES NOT CONTINUE THROUGH THE | | SECOND FLOOR. | | 10)(5) SHAFT ENCLOSURE, 2010 FBC-B 708.12 ENCLOSURE AT | | THE TOP. A SHAFT ENCLOSURE THAT DOES NOT EXTEND TO THE | | UNDERSIDE OF THE ROOF SHEATHING, DECK OR SLAB OF THE | | BUILDING SHALL BE ENCLOSED AT THE TOP WITH CONSTRUCTION | | OF THE SAME FIRE-RESISTANCE RATING AS THE TOPMOST FLOOR | | PENETRATED BY THE SHAFT, BUT NOT LESS THAN THE | | FIRE-RESISTANCE RATING REQUIRED FOR THE SHAFT | | ENCLOSURE. | | | | | | 10B)COMPLIED. | | | | 10C) FRONT ENTRY REDESIGN: | | 10C)(1) MISSING PRODUCT APPROVALS 2010 FBC-B 1609.1.2 | | PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS & | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS:(31)(A) EXTERIOR DOORS. | | | | 10C)(2) MISSING DIMENSIONS, NO INFORMATION FOR VERTICAL | | NOR HORIZONTAL STEEL FRAMING MEMBERS, PRODUCT APPROVALS | | WILL NEED TO BE DECIDED TO BE ABLE TO PRODUCE THE | | SIZING OF THE ROUGH OPENING. 2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, 2010 EDITION 107.2.1.3 ADDITIONAL DATA. | | THE BUILDING OFFICIAL MAY REQUIRE DETAILS, | | COMPUTATIONS, STRESS DIAGRAMS, AND OTHER DATA NECESSARY | | TO DESCRIBE THE CONSTRUCTION OR INSTALLATION AND THE | | BASIS OF CALCULATIONS. ALL DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA REQUIRED BY THE BUILDING OFFICIAL TO | | BE PREPARED BY AN ARCHITECT OR ENGINEER SHALL BE | | AFFIXED WITH THEIR OFFICIAL SEAL, SIGNATURE AND DATE AS | | STATE LAW REQUIRES. | | SHEET S-1 INDICATES A DETAIL FOR THE FRONT ENTRY SHEET | | S-2 DETAIL # 7. THIS DETAIL INDICATES THE INSTALATION | | OF A W 16X31 BEAM TO AC1540 C CHANNEL. | | IN THIS SAME DETAIL AT THE BOTTOM OF THE DETAIL HERE | | APPEARS TO BE A BOX BEAM, THERE IS NO INFORMATION ON | | THE SIZE OF THIS BEAM OR HOW IT IS TO INSTALLED, IT | | APPEARS THIS THIS THE STRUCTURAL MEMBER (HEADER) FOR | | THE FOLDING DOOR SYSTEM. | | | | 10D) NEW COMMENT: THE NEW FRONT ENTRY CONFIGURATION NOW | | CONSIST OF A SINGLE SWING DOOR AND A FOLDING DOOR | | SYSTEM THAT HAS INCORPARATED A SWING DOOR AS PART OF | | THE FOLDING DOOR SYSTEM. PLEASE NOTE THAT BOTH OF THE | | FRONT SWING DOORS WILL BE REQUIRED AS PART OF THE | | EGRESS DOORS SINCE A 3'-0" DOOR WILL ALLOW 170 | | OCCUPANTS. PLEASE PROVIDE COMPLIANCE WITH 1008.1.10 | | PANIC AND FIRE EXIT HARDWARE, HOW WILL THIS REQUIREMENT | | WORK AS PART OF THE FOLDING DOOR SYSTEM? | | | | 11) COMPLIED. | | | | 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 13) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-04-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-04-16 |
Time |
07:11 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-04-15 |
Time |
16:30 |
Sent To |
|
|
Notes |
2014-04-15 18:59:58 | BUILDING PLAN REVIEW | | PERMIT: 14030818 | | ADD: 526 CLEMATIS ST 1ST FLOOR CHANGE OF OCCUPANY/ | | EXTERIOR ALTERATIONS | | CONT: JM PROPERTIES OF WEST PALM BEACH, INC | | TEL: (561)756-5744 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | BLDG TYPE III-B SPRINKLERED | | | | 1ST REVIEW | | DATE: TUESDAY APRIL 16/ 2014 | | ACTION: DENIED | | | | THE LAST RENOVATIONS TO THIS BUILDING UNDER PERMIT | | 03060274, FIRST FLOOR MERCANTILE AND THE 2ND FLOOR R2 | | APARTMENTS, THIS REVIEW WILL BE CONSIDERED A CHANGE IN | | OCCUPANCY AND CHAPTER 9 OF THE EXISITNG BUILDING CODE. | | 901.3 CHANGE OF OCCUPANCY CLASSIFICATION. | | WHERE THE OCCUPANCY CLASSIFICATION OF A BUILDING | | CHANGES, THE PROVISIONS OF SECTIONS 902 THROUGH 912 | | SHALL APPLY. THIS INCLUDES A CHANGE OF OCCUPANCY | | CLASSIFICATION WITHIN A GROUP AS WELL AS A CHANGE OF | | OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A DIFFERENT | | GROUP. | | | | 1) THE COVERSHEET A0.0 INDICATES THE 1ST FLOOR | | OCCUPANCY CLASSIFICATION AS A A-3, THE PLANS APPEAR TO | | BE A NIGHTCLUB OR BAR / TAVERN WHICH IS A A2 OCCUPANCY, | | SEE 2010 FBC-B 303.1. | | | | 2) THE COVERSHEET A0.0 INDICATES THIS BUILDING TO BE | | FIRE SPRINKLERED, BUT THERE IS NO MENTION OF A FIRE | | SPRINKLER PLAN IN THE INDEX OF DRAWINGS NOR ANYWHERE | | ELSE IN THE PLANS. TRAVEL DISTANCES ARE SHOWN FOR | | NON-SPRINKLERED BUILDING. | | 2010 EXST BLDG CODE 904.1 GENERAL. | | FIRE PROTECTION REQUIREMENTS OF SECTION 912 SHALL APPLY | | WHERE A BUILDING OR PORTIONS THEREOF UNDERGO A CHANGE | | OF OCCUPANCY CLASSIFICATION. | | 912.2 FIRE PROTECTION SYSTEMS. | | FIRE PROTECTION SYSTEMS SHALL BE PROVIDED IN ACCORDANCE | | WITH SECTIONS 912.2.1 AND 912.2.2. | | | | EXST BLDG CODE 912.2.1 FIRE SPRINKLER SYSTEM. | | WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT | | REQUIRES AN AUTOMATIC FIRE SPRINKLER SYSTEM TO BE | | PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH | | CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH | | SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE | | CHANGE OF OCCUPANCY OCCURS. | | | | 2010 FBC-B F] 903.2.1.2 GROUP A-2. | | AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED FOR | | GROUP A-2 OCCUPANCIES WHERE ONE OF THE FOLLOWING | | CONDITIONS EXISTS: | | 1. THE FIRE AREA EXCEEDS 5,000 SQUARE FEET (464.5 M2); | | 2. THE FIRE AREA HAS AN OCCUPANT LOAD OF 100 OR MORE; | | | | EXST BLDG CODE 912.2.2 FIRE ALARM AND DETECTION SYSTEM. | | WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT | | REQUIRES A FIRE ALARM AND DETECTION SYSTEM TO BE | | PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH | | CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH | | SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE | | CHANGE OF OCCUPANCY OCCURS. EXISTING ALARM NOTIFICATION | | APPLIANCES SHALL BE AUTOMATICALLY ACTIVATED THROUGHOUT | | THE BUILDING. WHERE THE BUILDING IS NOT EQUIPPED WITH A | | FIRE ALARM SYSTEM, ALARM NOTIFICATION APPLIANCES SHALL | | BE PROVIDED THROUGHOUT THE AREA WHERE THE CHANGE OF | | OCCUPANCY OCCURS AND SHALL BE AUTOMATICALLY ACTIVATED. | | | | 3) SHEET A1.1 SHOWS NEW OUT SWING ENTRY DOORS PLEASE | | PROVIDE A SURVEY WITH THE DISTANCE FROM THE BUILDING TO | | THE PROPERTY LINE AT THE CLEMATIS OR FRONT OF THE | | BUILDING. 2010 FBC-B 3202.2 ENCROACHMENTS ABOVE GRADE | | AND BELOW 8 FEET IN HEIGHT. | | ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY ABOVE GRADE | | AND BELOW 8 FEET (2438 MM) IN HEIGHT SHALL BE | | PROHIBITED EXCEPT AS PROVIDED FOR IN SECTIONS 3202.2.1 | | THROUGH 3202.2.3. DOORS AND WINDOWS SHALL NOT OPEN OR | | PROJECT INTO THE PUBLIC RIGHT-OF-WAY. | | | | 4) SHEET A1.1 FRONT ENTRY AREA THERE IS A DISCREPANCY | | IN THE PLANS. THE 1ST FLOOR PLAN AND LIFE SAFETY PLAN | | SHOW TWO SWING ENTRY DOORS AND THE EXTERIOR FOLDING | | DOOR SYSTEM FOLDING OVER AND STCKING ALL THE WAY TO THE | | EAST OF THE OPENING, WHERE AS THE STRUCTURAL SHEET S1 | | SHOWS THE DOORS SPLITTING IN THE CENTER AND FOLDING | | EACH WAY. THE FOLDING DOOR SYSTEM THAT SPLITS IN THE | | MIDDLE WILL NOT ALLOW AN ACCESSIBLE ENRY AT THE SWING | | DOOR SINCE THERE WILL NOT BE 18 INCHES CLEAR AT THE | | LATCH SIDE OF THE DOOR 2010 FL ACCESS CODE 404.2.4.1 & | | FIGURE 404.2.4.1(A). | | | | 5) THE PLANS DO NOT HAVE ANY DETAILS AS FAR AS THE SILL | | FOR TTHE FOLDING DOOR SYSTEM, PLEASE PROVIDE COMPLIANCE | | WITH 2010 FL ACCESS CODE 404.2.5 THRESHOLDS. | | THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH | | (13 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN | | LEVEL AT DOORWAYS SHALL COMPLY WITH 302 AND 303. | | | | 6) SHEET A1.1 THE FRONT EXIT ENCLOSURE BOTH 1ST FLOOR & | | 2ND FLOOR LANDINGS SHOW THE ELEVATOR LOCATED IN THE | | EXIT ENCLOSURE. PLEASE REVIEW 2010 FBC-B 1022.3 & | | 1022.4. | | 2010 FBC-B 1022.3 | | EXIT ENCLOSURE OPENING PROTECTIVES SHALL BE IN | | ACCORDANCE WITH THE REQUIREMENTS OF SECTION 715. | | | | OPENINGS IN EXIT ENCLOSURES OTHER THAN UNPROTECTED | | EXTERIOR OPENINGS SHALL BE LIMITED TO THOSE NECESSARY | | FOR EXIT ACCESS TO THE ENCLOSURE FROM NORMALLY OCCUPIED | | SPACES AND FOR EGRESS FROM THE ENCLOSURE. | | | | ELEVATORS SHALL NOT OPEN INTO AN EXIT ENCLOSURE. | | | | 2010 FBC-B 1022.4 PENETRATIONS. | | PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT | | ENCLOSURE ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR INDEPENDENT | | VENTILATION OR PRESSURIZATION, SPRINKLER PIPING, | | STANDPIPES, ELECTRICAL RACEWAY FOR FIRE DEPARTMENT | | COMMUNICATION SYSTEMS AND ELECTRICAL RACEWAY SERVING | | THE EXIT ENCLOSURE AND TERMINATING AT A STEEL BOX NOT | | EXCEEDING 16 SQUARE INCHES (0.010 M2). SUCH | | PENETRATIONS SHALL BE PROTECTED IN ACCORDANCE WITH | | SECTION 713. | | THERE SHALL BE NO PENETRATIONS OR COMMUNICATION | | OPENINGS, WHETHER PROTECTED OR NOT, BETWEEN ADJACENT | | EXIT ENCLOSURES. | | | | 6A)(1) 2010 FBC-B 707.3.2 EXIT ENCLOSURES. THE | | FIRE-RESISTANCE RATING OF THE FIRE BARRIER SEPARATING | | BUILDING AREAS FROM AN EXIT SHALL COMPLY WITH SECTION | | 1022.1. | | | | 6A)(2) 2010 FBC-B 708.5 CONTINUITY. SHAFT ENCLOSURES | | SHALL BE CONSTRUCTED AS FIRE BARRIERS IN ACCORDANCE | | WITH SECTION 707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED | | IN ACCORDANCE WITH SECTION 712, OR BOTH, AND SHALL HAVE | | CONTINUITY IN ACCORDANCE WITH SECTION 707.5 FOR FIRE | | BARRIERS OR SECTION 712.4 FOR HORIZONTAL ASSEMBLIES AS | | APPLICABLE. | | | | 6A)(3) 2010 FBC-B 707.5 CONTINUITY. FIRE BARRIERS SHALL | | EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING | | ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF | | SHEATHING, SLAB OR DECK ABOVE AND SHALL BE SECURELY | | ATTACHED THERETO. SUCH FIRE BARRIERS SHALL BE | | CONTINUOUS THROUGH CONCEALED SPACES, SUCH AS THE SPACE | | ABOVE A SUSPENDED CEILING. SHEET A3.1 DETAIL A1 SHOWS A | | DETAIL FOR A 1 HR FIRE RATED WALL, BUT THE DETAIL DOES | | NOT INDICATE HOW IT WILL DEAL WITH A WOOD FLOOR TRUSS | | SYSTEM, OR HOW THE FIRE RATING MAY OCCUR AROUND | | HEADERS, AND WOOD BUILT UP FLOOR TRUSS GIRDERS. | | | | 7) SHEET A1.1 LIFE SAFETY PLAN IS MISSING THE RATING OF | | WALLS AND DOORS: | | 7A) THE FRONT AND REAR STAAIRWELLS DO NOT INDICATTE A 1 | | HOUR FIRE RATED WALL ALL THE WAY AROUND THE ENCLOSURE, | | 2010 FBC-B 1022.1 AND THE REQUIRED FIRE RATED DOORS PER | | 2010 FBC-B 715 & TABLE 715.4 1 HOUR RATED DOORS . | | | | 7B) THE ELEVATOR MACHINE ROOM 2010 FBC-B 3006.4. PLEASE | | NOTTE THE CEILING OF THIS ROOM WILL NEED TO BE FIRE | | RATED AS WELL IT WILL ABUT THE FRAMING MEMBERS OF THE | | STAIRWELL. 2010 FBC-B 1022.1 & 707 HORIZONTAL | | ASSEMBLIES. DOOR RATING 3/4 HR FIRE BARRIER TABLE | | 715.4. | | | | 8) UNDER THE 03060274 PERMIT THE STAIR ENCLOSURE AND | | ELEVATOR WERE A DIFFERENT CONFIGURATION, THE PLANS DO | | NOT IDENTIFY ANY CHANGES TO THE FLOOR FRAMING | | RECONFIGURATION? ADDITIONAL INFORMATION IS REQUIRED, | | 107.2.1.3. 2010 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 | | EDITION. | | | | 9) SHEET A2.1 HAS (3) AREAS WHERE WHITE OUT HAS BEEN | | USED ON THE PLANS. 107.2.1.4 2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, 2010 EDITION 2012. QUALITY OF BUILDING | | PLANS. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | RECORD RETENTION PROGRAM. OTHER THAN THE | | RECONFIGURATION OF THE EXIT ENCLOSURE SHOWS NO WORK TO | | BE COMPLETED UNDERTHIS PERMIT. | | | | | | | | 10) STRUCTURAL SHEET S-1: | | | | 10A) STRUCTURAL SHEET ELEVATOR DETAIL IS MISSING THE | | FOLLOWING : | | 10A)(1) TB- HEIGTH NOT PROVIDED. | | 10A)(2) B-24 THE HEIGHT OF THE BEAM TOP OR BOTTOM OF | | BEAM NOT PROVIDED | | 10A)(3) ELEVATOR DOES NOT SHOW A PIT OR RECESS FOR THE | | FLOOR OF THE ELEVATOR CAB TO BE LEVEL WITH THE FLOOR. | | 10)(4) THE ELEVATOR SHAFT DOES NOT CONTINUE THROUGH THE | | SECOND FLOOR. | | 10)(5) SHAFT ENCLOSURE, 2010 FBC-B 708.12 ENCLOSURE AT | | THE TOP. A SHAFT ENCLOSURE THAT DOES NOT EXTEND TO THE | | UNDERSIDE OF THE ROOF SHEATHING, DECK OR SLAB OF THE | | BUILDING SHALL BE ENCLOSED AT THE TOP WITH CONSTRUCTION | | OF THE SAME FIRE-RESISTANCE RATING AS THE TOPMOST FLOOR | | PENETRATED BY THE SHAFT, BUT NOT LESS THAN THE | | FIRE-RESISTANCE RATING REQUIRED FOR THE SHAFT | | ENCLOSURE. | | | | | | 10B) STEEL COLUMNS & W 16X31 BEAM | | | | 10B)(1) PLANS CALL FOR 5X5X5/16 OR 5 INCH DIA X ).258 | | STEEL COLUMNS. 2010 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 | | EDITION 2012 107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. | | | | 10B)(2) PLANS DO NOT PROVIDE THE SIZE FOR THE COLUMN | | BASE PLATE NOR TOP PLATE, THICKNESS, MATERIAL NOR THE | | BOLT LOCATION IN THE PLATE OR IF WELDED. 2010 WEST PALM | | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER | | 1, ADMINISTRATION, 2010 EDITION 2012 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS. SUCH DRAWINGS | | AND SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE | | FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | WITH THE TECHNICAL CODES. | | | | 10B)(3) NEW BATHROOM BEARING WALL DETAIL.DETAIL # 2 | | ONLY SHOWS THE BOTTOM OF THE STUD WALL DOES NOT | | INDICATE IF A SINGLE TOP PLATE IS REQUIRED OR IF DOUBLE | | TOP PLATE WILL BE REQUIRED? THE OTHER ISSUE IS WILL A | | STIFFNEER BE REQUIRED AS IN DETAIL # 3 FOR THE NEW | | CARRYING W 16X31 STEEL BEAM? IF SO WHAT TYPE OF | | MATERIALS AND NAILING PATTERN. | | | | 10C) FRONT ENTRY REDESIGN: | | 10C)(1) MISSING PRODUCT APPROVALS 2010 FBC-B 1609.1.2 | | PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS & | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS:(31)(A) EXTERIOR DOORS. | | | | 10C)(2) MISSING DIMENSIONS, NO INFORMATION FOR VERTICAL | | NOR HORIZONTAL STEEL FRAMING MEMBERS, PRODUCT APPROVALS | | WILL NEED TO BE DECIDED TO BE ABLE TO PRODUCE THE | | SIZING OF THE ROUGH OPENING. 2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, 2010 EDITION 107.2.1.3 ADDITIONAL DATA. | | THE BUILDING OFFICIAL MAY REQUIRE DETAILS, | | COMPUTATIONS, STRESS DIAGRAMS, AND OTHER DATA NECESSARY | | TO DESCRIBE THE CONSTRUCTION OR INSTALLATION AND THE | | BASIS OF CALCULATIONS. ALL DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA REQUIRED BY THE BUILDING OFFICIAL TO | | BE PREPARED BY AN ARCHITECT OR ENGINEER SHALL BE | | AFFIXED WITH THEIR OFFICIAL SEAL, SIGNATURE AND DATE AS | | STATE LAW REQUIRES. | | | | | | 11) SHEET A3.1 DEATIL # 4 INDICATES THE INSTALATION OF | | DROP CEILINGS, NOTE # 6 INDICATES THE TYPE OF FASTENERS | | TO BE USED IF THE INSTALATION IS FOR CONCRETE DECKS BUT | | NOT FOR WOOD FRAMED TRUSSES WITH METAL HI HAT FRAMING | | BETWEEN THE 5/8 INCH DRYWALL AND FLOOR TRUSS. 2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, ADMINISTRATION, 2010 EDITION 107.2.1.3 | | ADDITIONAL DATA. | | | | 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2015-04-07 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-04-07 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-04-07 |
Time |
12:53 |
Sent To |
|
|
Notes |
2015-04-07 12:55:57 | 4/7/15 | | PROJECT: 525 CLEMATIS | | PERMIT#: 14030818 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 4TH ELECTRICAL PLAN REVIEW | | ACTION: APPROVED WITH EXCEPTION. | | | | 1) ATOMIC TIMER IS NOT APPROVED FOR LIGHTING CONTROL AS | | DEFINED IN THE FBC 505.2 REVISE PLANS AND INSTALLATION | | FOR AN APPROVED LIGHTING CONTROL METHOD. FBC - E 505.2 | | | | 2) EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE | | LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND | | SPECIFIC PURPOSE OR USE. NEC 408.4. REVISE PANEL | | SCHEDULE TO COMPLY. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | | 2015-04-01 09:23:40 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2014-12-17 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-12-17 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-12-17 |
Time |
14:17 |
Sent To |
|
|
Notes |
2014-12-17 15:50:13 | 12/17/2014 | | PROJECT: 525 CLEMATIS | | PERMIT#: 14030818 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 3RD ELECTRICAL PLAN REVIEW | | ACTION: APPROVED WITH EXCEPTION. | | | | 1) ATOMIC TIMER IS NOT APPROVED FOR LIGHTING CONTROL AS | | DEFINED IN THE FBC 505.2 REVISE PLANS AND INSTALLATION | | FOR AN APPROVED LIGHTING CONTROL METHOD | | | | 2) EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE | | LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND | | SPECIFIC PURPOSE OR USE. NEC 408.4. REVISE PANEL | | SCHEDULE TO COMPLY. | | | | 3) PROVIDE A COMPREHENSIVE AS BUILT REVISION FOR | | ELECTRICAL LOAD SUMMARY CALCULATION BASED ON NEC | | ARTICLE 220, | | | | 4) REVISE THE ELECTRICAL SERVICE RISER DIAGRAM WITH | | SIZES OF ALL CONDUIT AND WIRE, | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2014-09-30 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2014-09-30 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2014-09-30 |
Time |
13:27 |
Sent To |
|
|
Notes |
2014-09-30 13:48:11 | 14030818 | | 526 CLEMATIS ST. | | INTERIOR RENOVATION | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | REVIEW COMMENTS. MANY OF THESE COMMENTS WERE PREVIOUSLY | | PROVIDED ( 4/3/14) ON THE FIRST REVIEW. | | | | | | VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS HAS A | | FAULT CURRENT RATING THAT IS SUFFICIENT AT NOMINAL | | CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE | | INTERRUPTED. SHOW THE FAULT CURRENT RATING OF THE MAIN | | DISCONNECTS AND PANELBOARDS. NEC 110.9 | | | | PROVIDE A SUMMARY LOAD CALCULATION. NEC 220.14; 220.40 | | | | PROVIDE A SAFETY LABELING SCHEDULE FOR FLASH PROTECTION | | FOR THE SERVICE, PANEL BOARDS AND MAIN DISCONNECTING | | MEANS. NEC 110.22, 110.16, 110.22 | | | | ON THE ELECTRIC PLAN SHOW ALL REQUIRED ACCESS AND SAFE | | WORKING CLEARANCES FOR THE ELECTRICAL SERVICE, MAIN | | DISCONNECTS AND PANEL BOARDS. NEC 110.26 | | | | ON THE PANEL SCHEDULE INCLUDE THE SHOW WINDOW LIGHTING | | AND A SIGN CIRCUIT. NEC 210.62, 408.4, 600.5 | | | | ALL RECEPTACLES LOCATED WITHIN SIX FEET OF SINKS IN THE | | BAR MUST BE GFCI PROTECTED. NEC 210.8 | | | | PROVIDE A LIGHTING DENSITY SUMMARY ON THE PLAN SHOWING | | COMPLIANCE WITH THE FLORIDA BUILDING ENERGY CODE | | REQUIREMENTS. FBC ENERGY CONSERVATION 505.3 | | | | PROVIDE LIGHTING CONTROLS FOR ENERGY CONSERVATION SO | | THAT THE INTERIOR AND EXTERIOR LIGHTING CONTROLS | | PROVIDED FUNCTION IN ACCORDANCE WITH THE FLORIDA ENERGY | | CODE. EXTERIOR AUTOMATIC CONTROLS SHALL BE CAPABLE OF | | RETAINING PROGRAMMING AND THE TIME SETTING DURING LOSS | | OF POWER FOR A PERIOD OF AT LEAST 10 HOURS. VERIFY THE | | LIGHTING AND SIGN TIME CLOCKS HAVE BATTERY BACKUP. FBC | | ENERGY CONSERVATION 505.2 | | | | ON THE ELECTRIC PLAN PROVIDE A LIGHTING SCHEDULE | | SHOWING FIXTURE SELECTION. INCLUDE EXIT LIGHTING WITH | | BATTERY BACKUP. FBC, ENERGY CONSERVATION 502.3.8; FBC | | 1011 | | | | ADD THE EXIT LIGHTING CIRCUIT TO THE LIGHTING PANEL. | | NEC 408.4 | | | | PROVIDE GFCI PROTECTED RECEPTACLES ON THE ROOF TO | | SERVICE THE MECHANICAL EQUIPMENT ON THE ROOF. NEC | | 210.8(B), 210.63 | | | | REVISE ELECTRICAL RISER PLAN TO SHOW PANEL ?EV?. SHOW | | FEEDER SIZE FOR PANEL ?B?. PROVIDE OVER CURRENT | | PROTECTION FOR PANEL ?A?. SHOW LOCATION OF PANEL ?A?. | | NEC 215.5 | | | | NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR THE | | ELEVATOR, ALARM SYSTEMS, SECURITY AND DATA SYSTEMS. | | | | ROBERT LECKY, CBO | | ELECTRICAL PLANS REVIEW | | 561-373-3701 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-04-03 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2014-04-03 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2014-04-03 |
Time |
12:06 |
Sent To |
|
|
Notes |
2014-04-03 14:23:19 | 14030818 | | 526 CLEMATIS ST. | | INTERIOR RENOVATION | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | REVIEW COMMENTS. | | | | SHOW THE LOCATION OF ALL ELECTRICAL SERVICES WITH MAIN | | DISCONNECTS WHICH ARE SERVING THIS LOCATION. INCLUDE AN | | ELECTRICAL DEMOLITION PLAN FOR THE ANY EXISTING SERVICE | | OR INTERIOR ELECTRIC BEING RENOVATED. NEC 230.2, | | 230.71, 230.72 | | | | SHOW THE FEEDERS AND LOCATION FOR ALL MECHANICAL | | EQUIPMENT CIRCUITS AND DISCONNECTS. NEC 215.5 | | | | VERIFY THE EXISTING OCCUPANCY AND PANEL SCHEDULE | | INCLUDE THE SHOW WINDOW LIGHTING AND A SIGN CIRCUIT. | | NEC 210.62; 600.5 | | | | VERIFY THE ELECTRICAL SERVICE MAINS SERVING THIS | | BUILDING ARE SIX OR LESS AND GROUPED IN ONE LOCATION. | | NEC 230.2, 230.71, 230.72 | | | | SHOW ALL METERS, GROUNDING, MAIN DISCONNECTS, FEEDERS | | AND PANEL BOARDS FOR THE BUILDING SERVICE INCLUDING ALL | | OTHER EXISTING OCCUPANCIES REQUIRING ELECTRICAL | | SERVICE. | | NEC 215.5, 230.2, 230.71, 230.72 | | | | VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS HAS A | | FAULT CURRENT RATING THAT IS SUFFICIENT AT NOMINAL | | CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE | | INTERRUPTED. NEC 110.9 | | | | VERIFY THE ELECTRICAL SERVICE LOAD IS NOT LESS THAN THE | | SUM OF ALL LOADS AS REQUIRED. NEC 215.5; 220.40 | | | | PROVIDE A SUMMARY LOAD CALCULATION. NEC 220.14; 220.40 | | | | PROVIDE A SAFETY LABELING SCHEDULE FOR FLASH PROTECTION | | FOR THE SERVICE, PANEL BOARDS AND MAIN DISCONNECTING | | MEANS. NEC 110.22, 110.16, 110.22 | | | | ON THE ELECTRIC PLAN VERIFY AND SHOW ALL REQUIRED | | ACCESS AND SAFE WORKING CLEARANCES FOR THE ELECTRICAL | | SERVICE, MAIN DISCONNECT, ELEVATOR CONTROLLERS, | | ELEVATOR DISCONNECTS AND ALL PANELBOARDS. INCLUDE THE | | SECOND FLOOR. NEC 110.26; 620.5 | | | | INCLUDE THE REQUIRED ELEVATOR BRANCH CIRCUITS ON THE | | PANEL SCHEDULE AND IN THE LOAD CALCULATION. NEC 110.22; | | 408.4; 620.23, 620.24 | | | | REVISE THE ELECTRIC PANEL DIRECTORY SO THAT ALL | | CIRCUITS ARE IDENTIFIED AS TO THEIR SPECIFIC PURPOSE OR | | USE. INCLUDE ALL CIRCUITS FEEDING THE SECOND FLOOR. NEC | | 408.4 | | | | ADD THE EXIT LIGHTING CIRCUIT TO THE LIGHTING PANEL. | | NEC 408.4 | | | | ALL RECEPTACLES LOCATED WITHIN SIX FEET OF SINKS IN THE | | BAR MUST BE GFCI PROTECTED. NEC 210.8 | | | | PROVIDE A LIGHTING DENSITY SUMMARY ON THE PLAN SHOWING | | COMPLIANCE WITH THE FLORIDA BUILDING ENERGY CODE | | REQUIREMENTS. FBC ENERGY CONSERVATION 505.3 | | | | VERIFY THE REQUIRED GFCI PROTECTED RECEPTACLE IS | | AVAILABLE TO SERVICE THE MECHANICAL EQUIPMENT. NEC | | 210.8(B) | | | | ON THE ELECTRIC PLAN PROVIDE A LIGHTING SCHEDULE | | SHOWING FIXTURE SELECTION INCLUDING EXIT LIGHTING WITH | | BATTERY BACK UP. FBC, ENERGY CONSERVATION 502.3.8; FBC | | 1011 | | | | INDICATE THE LOCATION OF THE ELEVATOR PANELBOARD. NEC | | 215.5 | | | | SHOW REQUIRED RECEPTACLES IN ELEVATOR EQUIPMENT ROOMS | | AND PITS WITH GFCI PROTECTION. NEC 620.23, 620.85 | | | | A SEPARATE BRANCH CIRCUIT SHALL SUPPLY ELEVATOR CAR | | LIGHTS. NEC 620.22 | | | | NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR THE | | ELEVATOR, ALARM SYSTEMS, SECURITY AND DATA SYSTEMS. | | | | ROBERT LECKY, CBO | | ELECTRICAL PLANS REVIEW | | 561-373-3701 | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2015-05-08 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-05-08 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
mgonzale |
Date |
2015-05-08 |
Time |
10:47 |
Sent To |
|
|
Notes |
2015-06-09 16:05:33 | SANITATION REQUIREMENTS: | | | | AFTER MEETING WITH THE DEVELOPER HE HAS AGREED TO | | OBTAIN A SEPARATE PERMIT FOR DUMPSTER AREA. ON THAT | | PERMIT HE WILL ADDRESS THE LOCATIONS OF THE DUMPSTERS | | INTENDED TO BE SERVICE BY THE CITY OF WEST PALM BEACH | | SANITATION DEPARTMENT. DUMPSTER MUST BE EASILY | | ACCESSIBLE BY THE CITY EQUIPMENT AND MANPOWER. THE | | MAXIMUM SIZE PROVIDED BY THE CITY BASED ON THE AREA | | DESCRIBED BY THE DEVELOPER IS 3 CU YD. DUMPSTER WHICH | | DEVELOPER AGREES TO ROLL OUT AND MAKE ACCESSIBLE. A | | HOLD WILL BE PLACED FOR INSPECTIONS ON THIS PERMIT | | UNTIL DUMPSTER PERMIT HAS BEEN APPLIED FOR. | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | | | | | | | | | 2015-05-08 10:58:22 | 1. DEMONSTRATE THAT THE PROPOSED DUMPSTER LOCATION IS | | ACCESSIBLE TO THE SOLID WASTE TRUCKS (35 FT LONG, 15 FT | | HIGH). IF IT IS INTENDED FOR DEVELOPER'S STAFF TO ROLL | | FULL TRASH BINS INTO THE ALLEY, THE LOCATION MUST NOT | | WILL IMPEDE TRAFFIC FLOW WHILE THE BINS ARE IN THE | | ALLEY OR COMPLETELY BLOCK TRAFFIC WHEN THE SOLID WASTE | | TRUCKS ARE COLLECTING THE GARBAGE. SECTION 74-35(A)(5) | | OF THE CODE OF ORDINANCES. | | | | 2. PROVIDE CALCULATIONS VERIFYING THAT THE PROPOSED | | SIZE AND QUANTITY OF TRASH BINS IS APPROPRIATE FOR THE | | WASTE YARDAGE ANTICIPATED TO BE GENERATED BY NEW USES | | IN THE BULDING. | | | | 3. WILL FOOD BE PREPARED OR SERVED IN THE BUILDING? IF | | SO, PLEASE INDICATE THE LOCATION OF THE GREASE TRAP | | INTERECEPTOR AND SUBMIT FOR A SEPARATE INTERCEPTOR | | PERMIT. | | | | KELLY CRANFORD, P.E. | | LAND DEVELOPMENT ENGINEER | | PUBLIC WORKS DEPARTMENT | | CITY OF WEST PALM BEACH | | [email protected] | | 561-494-1098 (OFFICE) | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-05-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-05-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-05-06 |
Time |
09:13 |
Sent To |
|
|
Notes |
2015-05-06 09:47:59 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | ADD EXIT SIGNS WHERE HAND DRAWN ON PLAN TO PROVIDE | | CLEAR DIRECTION OF EXIT PATH. | | | | FIRE INSPECTOR SHALL FIELD VERIFY ON FIRE INSPECTION. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2014-04-02 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-04-02 |
Time |
2:02 |
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-04-02 |
Time |
12:50 |
Sent To |
E |
|
Notes |
2014-04-02 13:44:06 | THE PERMIT PLAN WAS REVIEWED AND APPROVED WITH THE | | FOLLOWING COMMENTS BY PETER LEDUC, FIRE MARSHAL, BUREAU | | OF FIRE PREVENTION, WEST PALM BEACH FIRE RESCUE. | | | | 1. A FIRE SPRINKLER AND FIRE ALARM SYSTEM IS REQUIRED | | FOR THIS PROJECT. | | | | 2. ALL WORK ON THE FIRE SPRINKLER SYSTEM IS REQUIRED TO | | BE COMPLETED BY A CERTIFIED FIRE SPRINKLER CONTRACTOR | | AND SHALL COMPLY WITH NFPA 13. SEPARATE SHOP DRAWINGS, | | ARE REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY | | THE FIRE PREVENTION BUREAU PRIOR TO ANY WORK ON THE | | SYSTEM. | | | | 3. ALL FIRE ALARM SYSTEM WORK SHALL BE DONE BY A | | CERTIFIED FIRE ALARM CONTRACTOR AND COMPLY WITH NFPA | | 72. A SEPARATE SHOP DRAWING IS REQUIRED TO BE | | SUBMITTED, REVIEWED AND APPROVED BY THE FIRE PREVENTION | | BUREAU PRIOR TO ANY WORK ON THE SYSTEM. | | | | 4. CURRENT LIFE SAFETY SYSTEMS, SPRINKLER AND/OR FIRE | | ALARM, SHALL REMAIN ACTIVE THROUGHOUT THE CONSTRUCTION | | PERIOD. | | | | 5. ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | AND COMPLETE PROTECTION IS RETURNED. | | | | 6. NOTICE IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME | | TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR | | ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR | | MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE | | PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY | | DOOR. | | | | 7. TWO (2) ADDITIONAL EXIT SIGNS ARE REQUIRED AS | | INDICATED DUE TO THE PROPOSED EXIT SIGNS BEING NOT | | VISIBLE FROM THE OCCUPIED AREAS THEY SERVE. | | | | 8. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | BUILDING. | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2015-05-05 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-05-05 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-05-05 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2014-10-10 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-10-10 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-10-10 |
Time |
14:25 |
Sent To |
|
|
Notes |
2014-10-10 14:47:09 | MUST HAVE SEPARATE AWNINGS ON FACADE.....NOT PART OF | | THIS SCOPE.....WILL REVIEW FROM AWNING CONTRACTOR | 2014-10-10 14:26:15 | C13 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2014-03-21 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2014-03-21 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-03-21 |
Time |
09:18 |
Sent To |
|
|
Notes |
2014-03-21 09:19:34 | PROVISO: AWNINGS SHALL BE SEPARATED INTO TWO, ONE OVER | | DOOR AND ONE OVER MAIN STOREFRONT WINDOWS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2015-05-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-05-14 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-05-12 |
Time |
15:23 |
Sent To |
|
|
Notes |
2015-05-13 15:24:04 | PLANS WITH COUNTY IMPACT FEES STAMP SENT TO JIM WITMER | | FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2015-05-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-05-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-03-31 |
Time |
09:21 |
Sent To |
|
|
Notes |
2015-04-01 09:22:33 | RE-SUBMITTAL SENT TO C10 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2015-03-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-03-13 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-02-05 |
Time |
07:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-12-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2014-12-29 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-11-19 |
Time |
16:24 |
Sent To |
|
|
Notes |
2014-11-24 16:25:19 | RE-SUBMITTAL SENT TO C10 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-10-15 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-10-15 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-09-29 |
Time |
16:57 |
Sent To |
|
|
Notes |
2014-09-29 16:58:19 | RE-SUBMITTAL SENT TO C13 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-04-24 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2014-04-24 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-03-21 |
Time |
10:47 |
Sent To |
|
|
Notes |
2014-03-24 10:52:49 | INCOMING SENT TO C-05. JW |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
5 |
Status |
N |
Date |
2015-05-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-05-14 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-05-14 |
Time |
|
Sent To |
|
|
Notes |
2015-05-14 14:26:11 | P. B. C. IMPACT FEES | | PLANS STAMPED NO FEES DUE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
F |
Date |
2015-04-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-04-25 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-04-25 |
Time |
14:14 |
Sent To |
|
|
Notes |
2015-04-25 13:59:40 | IMPACT FEES | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2014-12-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-12-08 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-12-08 |
Time |
13:19 |
Sent To |
|
|
Notes |
2014-12-08 13:19:30 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2014-10-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-10-08 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-10-08 |
Time |
08:16 |
Sent To |
|
|
Notes |
2014-10-08 08:16:47 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2014-04-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-04-16 |
Time |
07:12 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-04-16 |
Time |
07:12 |
Sent To |
|
|
Notes |
2014-04-16 07:12:21 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
N |
Date |
2017-05-10 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-05-10 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-05-10 |
Time |
13:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2015-03-10 |
|
|
Cont ID |
|
Sent By |
HMOSER |
Date |
2015-03-10 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-03-10 |
Time |
10:43 |
Sent To |
|
|
Notes |
2015-03-10 13:47:57 | PASS PROVISO | | 1) REFER TO SECTION 304.1 GENERAL. PERVADE THE | | MANUFACTURER'S | | INSTALLATION INSTRUCTIONS ON THE AIR CONDITIONING | | EQUIPMENT | | BY FINAL INSPECTION. (AND CLOTHS DRYER) | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2014-12-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2014-12-29 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-12-29 |
Time |
10:10 |
Sent To |
|
|
Notes |
2014-12-29 13:20:23 | PLAN DENIED | | 1) REFER TO SECTION 602.2.1 MATERIALS WITHIN PLENUM'S | | 2010 FBC (M) DOORS ARE PART OF PLENUM. | | 2) REFER TO SECTION 301.12 WIND RESISTANCE. PROVIDE | | A DETAIL FROM THE ENGINEER ON CURB TIEDOWN TO ROOF, | | CONDENSER STAND TIE DOWN TO ROOF, RTU TIEDOWN TO | | CURB, CONDENSER TIEDOWN TO STAND ON MECHANICAL PLAN. | | 3) REFER TO SECTION 606.2.1 SUPPLY AIR SYSTEM, 606.3 | | INSTALLATION, 606.4.1 SUPERVISION FBC (M) 2010 | | 4) REFER TO SECTION 304.1 GENERAL 2010 FBC (M) | | | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2014-10-08 |
|
|
Cont ID |
|
Sent By |
rbergsma |
Date |
2014-10-08 |
Time |
|
Rev Time |
0.50 |
Received By |
rbergsma |
Date |
2014-10-08 |
Time |
|
Sent To |
|
|
Notes |
2014-10-08 14:19:31 | PREVIOUS MECHANICAL COMMENTS WERE NOT ADDRESSED | | ALSO -------- THE M-1 SHEETS IN TWO OF THE PLANS | | SUBMITTED ARE TO LIGHT TO READ | | AND THE THIRD M-2 IS DIFFERENT THAN THE OTHER TWO M-2 | | 'S | | | | CORRECT AND RESUBMIT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2014-04-24 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2014-04-24 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2014-04-24 |
Time |
12:38 |
Sent To |
|
|
Notes |
2014-04-24 13:12:43 | MECHANICAL PLAN DENIED | | 1) PROVIDE ENERGY CALCULATION WITH THE | | PLAN PER SECTION 503.2.1 CALCULATION | | OF HEATING AND COOLING LOADS. 2010 | | FLORIDA ENERGY CODE. | | 2) PROVIDE A DETAIL FROM THE ENGINEER | | ON THE CURB TO ROOF TIEDOWN AND CONDENSER | | TO CURB TIEDOWN . | | PROVIDE TYPE OF FASTENERS SIZE AND HOW FAR APART | | PER SECTION 303.12 WIND RESISTANCE 2010 FBC (M) | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2015-04-23 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-23 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-23 |
Time |
11:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2015-02-15 |
|
|
Cont ID |
|
Sent By |
TKLARGE |
Date |
2015-02-15 |
Time |
04:34 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-02-13 |
Time |
11:05 |
Sent To |
|
|
Notes |
2015-02-15 04:32:33 | PLEASE CONTACT ME AT 561-805-6692 TO MAKE AN | | APPOINTMENT TO COME IN AND REVIEW THE WATER AND | | SANITARY RISERS. THERE ARE TOO MANY CODE ISSUES TO LIST | | IN A CODE REVIEW.THANK YOU. WPB AMEND. TO 2010 FBC | | SEC.107.2.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2014-11-27 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-11-27 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-11-27 |
Time |
07:59 |
Sent To |
|
|
Notes |
2014-11-27 09:28:37 | 1)TABLE 403.1 FOOTNOTE "G" OF 2010 FL. PLUMBING CODE | | REQUIRES A UNISEX BATHROOM IN ASSEMBLY OCCUPANCIES | | WHERE AN AGGREGATE OF SIX OR MORE MALE AND FEMALE WATER | | CLOSETS ARE REQUIRED IN ACCORDANCE WITH THE 2010 FPC | | SEC.403.5. SHOW THE REQUIRED UNISEX TOILET ROOM ON THE | | PLANS AND PROVIDE A SANITARY AND WATER RISER FOR | | REVIEW. 2ND REQUEST. THE UNISEX TOILET ROOM SHALL | | COMPLY WITH THE FL. ACCESSIBILITY CODE. | | 2) SUBMIT AN ENLARGED RESTROOM FLOOR PLAN FOR THE FIRST | | FLOOR. SHOW ALL REQUIRED FLOOR SPACE FOR THE | | HANDICAPPED FIXTURES. THE RESTROOMS SHALL FULLY COMPLY | | WITH THE 2010 FL. ACCESSIBILITY CODE.THE TOILET | | COMPARTMENTS SHALL COMPLY WITH FAC SEC.604.8.1.6.SINCE | | THIS IS A CHANGE OF OCCUPANCY. 2ND REQUEST. | | 3) SHT. P-2 - THE FIRST FLOOR SANITARY PLAN IS DRAWN | | VERY LIGHT AND IS DIFFICULT TO READ. SUBMIT A PLAN THAT | | IS CLEAR IN DETAIL AND LEGIBLE. WPB AMEND. TO 2001 FBC | | SEC. 107.2.1. 2ND REQUEST. | | 4) THE RESTROOMS ON THE 2ND FLOOR SHALL FULLY COMPLY | | WITH THE FL. ACCESSIBILITY CODE. THE TOILET | | COMPARTMENTS SHALL COMPLY WIT FAC SEC.604.8.1.6.SHOW | | ALL THE REQUIRED CLEAR FLOOR SPACE PER FAC SEC. 306 & | | 604.3.2ND REQUEST. | | 5) SHT. P-4 - THE 2ND FLOOR SANITARY ISOMETRIC FOR THE | | WOMEN'S RESTROOM #205 HAS A DRY VENT FOR THE P-1 | | FIXTURE. EVERY DRY VENT CONNECTING TO A HORIZONTAL | | DRAIN SHALL COMPLY WITH THE 2010 FPC SEC.905.3. 2ND | | REQUEST. | | 6) THE FLOOR DRAINS ON THE FIRST FLOOR SANITARY | | ISOMETRIC ARE NOT VENTED. PROVIDE THE PROPER SIZE VENTS | | PER THE FPC SEC.906.1, 901.2. 2ND REQUEST. | | 7) THE P-5 FIXTURE SHALL BE PROPERLY TRAPPED. FPC | | 1002.1. 2ND REQUEST. | | 8) THE SINGLE FLOOR DRAIN IN THE BAR AREA (#209) IS NOT | | VENTED.FPC SEC.906.1.2ND REQUEST. | | 9)THE NUMBER OF WATER CLOSETS BEING WET VENTED IN THE | | FIRST AND SECOND FLOOR RESTROOMS EXCEEDS THE NUMBER | | PERMITTED BY FPC SEC. 909. ALSO, URINALS ARE NOT | | PERMITTED ON THE HORIZONTAL WET VENTS. 2ND REQUEST. | | 10) SHT. P-3 - THE 2ND FLOOR DOMESTIC (WATER PLAN) IS | | DRAWN VERY LIGHT AND IS DIFFICULT TO READ. SUBMIT A | | PLAN THAT IS CLEAR IN DETAIL AND LEGIBLE. WPB AMEND. TO | | 2001 FBC SEC. 107.2.1. | | 11) THE RESPONSE NARRATIVE FROM ELLIS & GRITTER | | ADDRESSES COMMENTS FROM THE APRIL REVIEW NOT THE | | NOVEMBER REVIEW. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2014-11-27 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2014-10-14 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-10-14 |
Time |
14:47 |
Sent To |
|
|
Notes |
2014-10-14 15:04:38 | 1) NEITHER THE COVERSHEET NOR ANY OF THE PLUMBING | | SHEETS PROVIDE THE REQUIRED MINIMUM FIXTURE COUNT PER | | THE 2010 FBC-PLUMBING, TABLE 403.1. | | 2) FOOTNOTE "G" OF TABLE 403.1 OF THE 2010 | | FBC-PLUMBING, REQUIRES A UNISEX BATHROOM IN MERCANTILE | | AND ASSEMBLY OCCUPANCIES WHERE AN AGGREGATE OF SIX OR | | MORE MALE AND FEMALE WATER CLOSETS ARE REQUIRED. | | 3) SUBMIT AN ENLARGED RESTROOM FLOOR PLAN FOR THE THE | | FIRST FLOOR. | | 4) THE RESTROOMS ON THE SECOND FLOOR SHALL COMPLY WITH | | THE FLORIDA ACCESSIBILITY CODE FOR BUILING | | CONSTRUCTION. | | 5) SHT. P-2 - THE 1ST FLOOR SANITARY PLAN IS ILLEGIBLE. | | SUBMIT A PLAN THAT IS CLEAR IN DETAIL. WPB AMEND. TO | | 2010 FBC SEC. 107.2.1. | | 6) THE 2ND FLOOR SANITARY ISOMETRIC HAS DRY VENTS FOR | | THE P-1 FIXTURES. EVERY DRY VENT CONNECTING TO A | | HORIZONTAL DRAIN SHALL CONNECT ABOVE THE CENTERLINE OF | | THE HORIZONTAL DRAIN PIPE PER THE 2010 FPC SEC.905.3. | | 7) THE FLOOR DRAINS ON THE FIRST FLOOR ARE NOT VENTED. | | FPC SEC.906.1. 901.2. | | 8) THE SANITARY LINE FOR FIXTURE P-1 ON THE FIRST FLOOR | | CONNECTS TO NOTHING. CLARIFY. | | 9) P-5 FIXTURES REQUIRE TRAPS. | | 10) THE SINGLE FLOOR DRAIN IN THE BAR AREA ON THE | | SECOND FLOOR IS NOT VENTED. FPC SEC.906.1 | | 11) THE NUMBER OF WATER CLOSETS BEING WET VENTED IN THE | | SECOND FLOOR RESTROOMS EXCEEDS THE NUMBER PERMITTED BY | | SEC.909 OF THE FPC. ALSO, URINALS ARE NOT PERMITTED ON | | A WET VENT. | | 12) BASED ON THE SHOWN OCCUPANT LOAD, THE MINIMUM | | NUMBER OF REQUIRED PLUMBING FIXTURES ARE AS FOLLOWS: | | A) 7 WATER CLOSETS, 4 LAVS FOR THE MALES | | B) 7 WATER CLOSETS, 4 LAVS FOR THE FEMALES | | C) 1 SERVICE SINK | | D) 2 DRINKING FOUNTAINS | | 13) CITY RECORDS ( PERMIT #03060274 ) SHOW THE SECOND | | FLOOR OF THIS BUILDING AS APARTMENTS, WHICH IS AN R-2 | | OCCUPANCY. THIS WILL BE CONSIDERED A CHANGE OF | | OCCUPANCY AND MUST COMPLY WITH CHAPT.9 , SECS. 902-913 | | OF THE 2010 FBC, EXISTING BUILDING CODE. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-04-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-04-16 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-04-16 |
Time |
07:26 |
Sent To |
|
|
Notes |
2014-04-16 08:44:54 | PLUMBING PLAN REVIEW | | PERMIT: 14030818 | | ADD: 526 CLEMATIS ST 1ST FLOOR CHANGE OF OCCUPANY/ | | EXTERIOR ALTERATIONS | | CONT: JM PROPERTIES OF WEST PALM BEACH, INC | | TEL: (561)756-5744 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | BLDG TYPE III-B SPRINKLERED | | | | 1ST REVIEW | | DATE: WED. APRIL 16/ 2014 | | ACTION: DENIED | | | | THE LAST RENOVATIONS TO THIS BUILDING UNDER PERMIT | | 03060274, FIRST FLOOR MERCANTILE AND THE 2ND FLOOR R2 | | APARTMENTS, THIS REVIEW WILL BE CONSIDERED A CHANGE IN | | OCCUPANCY AND CHAPTER 9 OF THE EXISITNG BUILDING CODE. | | 901.3 CHANGE OF OCCUPANCY CLASSIFICATION. | | WHERE THE OCCUPANCY CLASSIFICATION OF A BUILDING | | CHANGES, THE PROVISIONS OF SECTIONS 902 THROUGH 912 | | SHALL APPLY. THIS INCLUDES A CHANGE OF OCCUPANCY | | CLASSIFICATION WITHIN A GROUP AS WELL AS A CHANGE OF | | OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A DIFFERENT | | GROUP. | | | | 1) THE COVERSHEET A0.0 INDICATES THE 1ST FLOOR | | OCCUPANCY CLASSIFICATION AS A A-3, THE PLANS APPEAR TO | | BE A NIGHTCLUB OR BAR / TAVERN WHICH IS A A2 OCCUPANCY, | | SEE 2010 FBC-B 303.1. | | | | 2) NEITHER THE COVERSHEET NOR ANY OF THE PLUMBING | | SHEETS PROVIDE THE REQUIRED MINIMUM FIXTURE COUNT PER | | 2010 FBC-P TABLE 403.1. | | | | 3) THE PLANS DO NOTSTATE IF THIS TENANCY IS TO BE A | | RESTARAUNT OR A NIGHTCLUB. IF TO BE CONSIDERED A | | RESTARAUNT NO KITCHEN APPLIANCES HAVE BEEN SHOWN | | ALTHOUGH A 3 COMPARTMENT SINK IS SHOWN, PLEASE PROVIDE | | WHAT YPES OF FOOD WILL BE PREPARED. IF A RESTARAUNT | | THEN A SEPARATE PERMIT FOR A GREASE INTERCEPTOR WOULD | | BE REQUIRED. 2010 FBC-P 1003.3.1 GREASE INTERCEPTORS | | AND AUTOMATIC GREASE REMOVAL DEVICES REQUIRED. THE | | STORAGE ROOM APPEARS TO BE SET UP FOR A FUTURE KITCHEN | | WITH HOT AND COLD DOMESTIC WATER AND FLOOR DRAINS? | | | | 4) SHEET P3 SANITARY & DOMESTIC ISOMETRIC | | | | 4A) FLOOR DRAINS IN RESTROOM & STORAGE ROOM ARE MISSING | | TRAP PRIMERS. 2010 FBC-P 1002.4 TRAP SEALS. EACH | | FIXTURE TRAP SHALL HAVE A LIQUID SEAL OF NOT LESS THAN | | 2 INCHES (51 MM) AND NOT MORE THAN 4 INCHES (102 MM), | | OR DEEPER FOR SPECIAL DESIGNS RELATING TO ACCESSIBLE | | FIXTURES. WHERE A TRAP SEAL IS SUBJECT TO LOSS BY | | EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE | | INSTALLED. TRAP SEAL PRIMER VALVES SHALL CONNECT TO THE | | TRAP AT A POINT ABOVE THE LEVEL OF THE TRAP SEAL. A | | TRAP SEAL PRIMER VALVE SHALL CONFORM TO ASSE 1018 OR | | ASSE 1044. | | | | 4B) FLOOR DRAINS AND TRAP PRIMER SEALS AND VENTING ARE | | MISSING ON THE SANITARY ISOMETRIC FOR THE STORAGE | | SUPPLY ROOM. 2010 FBC-P 905.3, & 1002.4. | | | | 4C) THE URINAL IN THE MENS RESTROOM DOES NOT SHOW ANY | | VENT, NOTE WET VENT SYSTEMS ARE ONLY FOR RESIDENTIAL 1 | | & 2 FAMILY USAGE. WOULD REQUIRE A INDIVIDUAL VENT. | | 2010 FBC-P 908.1, 909.1 AND BOAF INFORMAL | | INTERPRETATION REPORT # 6090, THESE INTERPRETATIONS ARE | | THE RESULT OF INPUT PROVIDED BY THE BOAF CODE | | DEVELOPMENT COMMITTEE, THE FLORIDA DEPARTMENT OF | | BUSINESS & PROFESSIONAL REGULATION (DBPR), THE | | INTERNATIONAL CODE COUNCIL (ICC) AND | | SUBJECT-MATTER-EXPERTS IN THE CONSTRUCTION | | INDUSTRY/PROFESSIONS. | | | | 4D) IN THE MENS RESTROOM THE LAV, URINAL NOR FLOOR | | DRAIN PROVIDE THE TRAP AND PIPE SIZES, 2010 FBC-P TABLE | | 709.1. | | | | 4E) IN THE FRONT BAR AREA WHERE THE 3 COMPARTMENT SINK, | | HAND SINK AND FLOOR SINK ARE SHOWN ON THE SANITARY | | ISOMETRIC, NONE OF THE BRANCH LINES AND TRAPS ARE | | SIZED, 2010 FBC-P TABLE 709.1. | | | | 4F) THE SANITARY ISOMETRIC DOES NOT PROVIDE WHAT SIZE | | ANY OF THE VENTS ARE AND IF REVENTED AND WHICH VENT IS | | GOING THROUGH TO THE ROOF? 2010 FBC-B 903.1.2. | | | | 4G) SHEET P2 SHOWS HOT AND COLD WATER BEING BROUGHT | | OVER INTO THE STORAGE ROOM BUT THEY ARE NOT SHOWWN ON | | THE DOMESTIC WATER ISOMETRIC. 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED WHEN | | APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. | | | | 5) SHEET P4: | | | | 5A) PIPE HANGER DETAILS SHOW I BEAM OR BAR JOIST HANGER | | AND ANCHORS FOR CONCRETE DECKS THE FLOOR SYSTEM IS WOOD | | TRUSS SYSTEM PLEASE SUPPLY THE APPROPRIATE DETAILS FOR | | THE INSTALATION. 2010 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 | | EDITION 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | DISCREPANCY IN DETAILS, CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. | | 2010 FBC-P ; | | 308.3 MATERIALS. | | HANGERS, ANCHORS AND SUPPORTS SHALL SUPPORT THE PIPING | | AND THE CONTENTS OF THE PIPING. HANGERS AND STRAPPING | | MATERIAL SHALL BE OF APPROVED MATERIAL THAT WILL NOT | | PROMOTE GALVANIC ACTION. | | | | 308.4 STRUCTURAL ATTACHMENT. | | HANGERS AND ANCHORS SHALL BE ATTACHED TO THE BUILDING | | CONSTRUCTION IN AN APPROVED MANNER. | | | | 308.5 INTERVAL OF SUPPORT. | | PIPE SHALL BE SUPPORTED IN ACCORDANCE WITH TABLE 308.5. | | | | 5B) WATER HEATER RACK MOUNTING DETAIL, PLEASE PROVIDE | | INFORMATION ON THE RACK, RACK CARRYING CAPACITY AND | | TYPE OF ANCHORS TO BE USED AND TYPE OF MATERIAL THE | | ANCHORS WILL FASTENING INTO. 2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, 2010 EDITION 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. . | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2015-05-05 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2015-05-05 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2015-05-05 |
Time |
09:09 |
Sent To |
|
|
Notes |
2015-05-05 09:23:36 | PROVISO: DUMPSTER SHALL BE ENCLOSED AND SCREENED | | ACCORDING TO CITY CODE. | | 2. ALCOHOL LICENSE FOR A BAR/CLUB IS SUBJECT TO CITY | | COMMISSION APPROVAL. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2014-10-10 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2014-10-10 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-10-10 |
Time |
13:42 |
Sent To |
|
|
Notes |
2014-10-10 13:47:55 | PROVISO: DUMPSTER SHALL BE ENCLOSED AND SCREENED. | | ALCOHOL LICENSE IS SUBJECT TO CITY COMMISSION APPROVAL. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2014-03-27 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2014-03-27 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-03-27 |
Time |
08:55 |
Sent To |
|
|
Notes |
2014-03-27 12:14:52 | 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY. | | 2. DOORS CANNOT OPEN INTO THE SETBACK AREA OR ROW. | | PLEASE INDICATE THE PROPERTY LINE ON FLOOR PLANS. | | 3. DUMPSTER SHALL BE ENCLOSED AND SCREENED SECTION | | 94-444(B). | | 4. DUMPSTER LOCATION REQUIRES APPROVAL FROM THE | | SANITATION SUPERINTENDENT. PLEASE CONTACT FERDINAND | | RIVERA AT 822-2076. | | 5. BASED ON SUBMITTED DRAWINGS THE PROPOSED BUSINESS | | SEEMS TO BE A BAR. THAT USE IS NOT CURRENTLY PERMITTED | | AT 526 CLEMATIS STREET, THERE ARE ALREADY TWO ALCOHOLIC | | BEVERAGE ESTABLISHMENTS IN THE APPLICABLE BLOCK. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|
|
Account Summary | Usage Policy | Privacy Policy