Plan Review Stops For Permit 14030309 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2014-10-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-10-03 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-10-03 |
Time |
17:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2014-08-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-08-21 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-08-21 |
Time |
10:56 |
Sent To |
|
|
Notes |
2014-08-21 10:56:50 | RESIDENTIAL (R3) REVISION FIFTH CHECKLIST: | | CODE: 2010 FBC. | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR THE "NEW DOOR TYPE A STEEL DOOR". NO | | PRODUCT APPROVAL WAS SUBMITTED THIS TIME. | | | | | | ***** PREVIOUS COMMENTS REGARDING SITE SPECIFIC DOOR | | PRODUCT APPROVAL: | | | | 1- PRODUCT APPROVAL INFORMATION SUBMITTED FOR CUSTOM | | DOOR "A" NEED THE FOLLOWING INFORMATION FOR ROBERT | | BROWN (BUILDING OFFICIAL) APPROVAL (PRODUCT APPROVAL | | REQUIRED BY DCA RULE 9N-3): | | A) WHERE WAS EXISTING DOOR TAKEN FROM?. PLANS DON'T | | SHOW ANY DOOR TO BE REMOVED. | | B) SIGNED AND SEALED COMPLETE ENGINEER DOOR COMPARATIVE | | ANALYSIS. | | C) ENGINEER TO REVISE THE DESIGN LOAD PER PERMITTED | | DRAWINGS. -29.3 PSF DESIGN LOAD DOESN'T MATCH APPROVED | | DRAWINGS. | | D) ENGINEER TO PROVIDE COMPLETE INFORMATION FOR THE | | HISTORIC DOOR. WOOD TYPE, THICKNESS, GLASS: TYPE, | | THICKNESS, SIZES, ETC. | | E) ENGINEER TO PROVIDE COMPLETE HISTORIC DOOR JAMB | | SPECIFICATIONS AND ATTACHMENT TO THE STRUCTURE. | | F) ENGINEER TO PROVIDE COMPLETE DOOR OPENING FRAMING | | DETAILS AND SPECIFICATIONS. | | | | ***NOTE: ENGINEER TO CONTACT ROBERT BROWN (BUILDING | | OFFICIAL) TO COORDINATE PRODUCT APPROVAL REQUIRED | | INFORMATION. CALL (561)805-6652 OR E-MAIL | | [email protected]. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ABOVE PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS | | TO FBC. (REPEAT COMMENT). | | | | | | ***NOTE: PLEASE PROVIDE A RESPONSE LETTER ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-06-24 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-06-24 |
Time |
14:51 |
Sent To |
|
|
Notes |
2014-06-24 14:51:41 | RESIDENTIAL (R3) REVISION COMMENTS. | | CODE: 2010 FBC. | | | | 1- PRODUCT APPROVAL INFORMATION SUBMITTED FOR CUSTOM | | DOOR "A" NEED THE FOLLOWING INFORMATION FOR ROBERT | | BROWN (BUILDING OFFICIAL) APPROVAL (PRODUCT APPROVAL | | REQUIRED BY DCA RULE 9N-3): | | A) WHERE WAS EXISTING DOOR TAKEN FROM?. PLANS DON'T | | SHOW ANY DOOR TO BE REMOVED. | | B) SIGNED AND SEALED COMPLETE ENGINEER DOOR COMPARATIVE | | ANALYSIS. | | C) ENGINEER TO REVISE THE DESIGN LOAD PER PERMITTED | | DRAWINGS. -29.3 PSF DESIGN LOAD DOESN'T MATCH APPROVED | | DRAWINGS. | | D) ENGINEER TO PROVIDE COMPLETE INFORMATION FOR THE | | HISTORIC DOOR. WOOD TYPE, THICKNESS, GLASS: TYPE, | | THICKNESS, SIZES, ETC. | | E) ENGINEER TO PROVIDE COMPLETE HISTORIC DOOR JAMB | | SPECIFICATIONS AND ATTACHMENT TO THE STRUCTURE. | | F) ENGINEER TO PROVIDE COMPLETE DOOR OPENING FRAMING | | DETAILS AND SPECIFICATIONS. | | | | ***NOTE: ENGINEER TO CONTACT ROBERT BROWN (BUILDING | | OFFICIAL) TO COORDINATE PRODUCT APPROVAL REQUIRED | | INFORMATION. CALL (561)805-6652 OR E-MAIL | | [email protected]. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ABOVE PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS | | TO FBC. (REPEAT COMMENT). | | | | 3- ENGINEER TO REVISE PLANS SHOWING: | | A) SAFETY GLASS FOR WINDOW ADJACENT TO THE SPA. SEC. | | R308.4(6). | | ***NOTE: 3M SAFETY & SECURITY WINDOW FILM SPECS WERE | | PROVIDED. ENGINEER TO REVISE PLANS SHOWING THE | | INSTALLATION OF THIS 3M FILM AS THE PROPOSED MEANS OF | | COMPLYIING WITH THE SAFETY GLASS REQUIREMENTS. | | SEC. 104.11 CITY AMENDMENTS TO FBC (ALTERNATIVE | | MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND | | EQUIPMENT). | | | | B) SAFETY GLASS FOR WINDOW ADJACENT TO THE NEW STAIRWAY | | (TOP AND BOTTOM). SEC. R308.4.(7) AND SEC. R308.4(8). | | (***NOTE: SAME RESPONSE TO ITEM #3(A) ABOVE APPLIES). | | | | ***NOTE: PLEASE PROVIDE A RESPONSE LETTER ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2014-05-21 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-06-06 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-05-21 |
Time |
17:01 |
Sent To |
|
|
Notes |
2014-05-21 17:03:41 | RESIDENTIAL (R3) REVISION THIRD CHECKLIST. | | CODE: 2010 FBC. | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: | | | | A) PROPOSED CUSTOM DOOR "A" SPECIFIED ON PLANS. | | (***NOTE: THE DOOR DOESN'T HAVE TO BE IMPACT BECAUSE OF | | THE 25% EXCEPTION ON SEC. 606.4 OF 2010 FBC-EXISTING | | BUILDING. ****NOTE***** GLAZING IN DOOR NEEDS TO COMPLY | | WITH THE SAFETY GLASS REQUIRED BY HAZARDOUS LOCATION | | SEC. R308.4(1). A PRODUCT APPROVAL IS STILL REQUIRED | | FOR ALL NEW DOORS. HISTORIC DOESN'T WAIVE THIS | | REQUIREMENT). | | | | *******RESPONSE TO INFORMATION SUBMITTED: | | (A) NO DOOR PRODUCT APPROVAL WAS SUBMITTED. ONLY | | INFORMATION FOR HURRICANE SHUTTERS WAS SUBMITTED. | | | | (B) PROVIDE FLORIDA PRODUCT APPROVAL OR MIAMI-DADE NOA | | FOR THE HURRICANE SHUTTERS TO BE USED AS REQUIRED BY | | DCA RULE 9N-3. INFORMATION SUBMITTED IS NOT AN APPROVED | | PRODUCT APPROVAL. IF THERE IS NOT AN APPROVED FLORIDA | | OR MIAMI-DADE PRODUCT APPROVAL, THEN MANUFACTURER MAY | | APPLY FOR LOCAL PRODUCT APPROVAL. ( NOTE: SHUTTERS ARE | | NOT REQUIRED. SEE ITEM 1(A) ABOVE). | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ABOVE PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS | | TO FBC. (REPEAT COMMENT). | | | | 3- FLAT ROOF ASSEMBLY: RAS 117 CALCULATIONS SUBMITTED | | NEED THE ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS | | REQUIRED BY CHAPTER 471 FLORIDA STATUTE WHEN SUBMITTING | | INFORMATION FOR PUBLIC RECORDS. COPIES ARE NOT ALLOWED. | | | | 4- A)SPECIFY SAFETY GLASS FOR WINDOW ADJACENT TO THE | | SPA. SEC. R308.4(6). | | (***NOTE: HISTORIC DOESN'T WAIVE LIFE SAFETY ISSUES. | | THE LIFE SAFETY CONDITION WAS CREATED BY THE NEW | | ADDITION. PLEASE REVIEW SEC. 1104 AND SEC. 1105 OF THE | | 2010 FBC-EXISTING BUILDING TO ADDRESS THE NEW LIFE | | SAFETY ISSUES). | | | | B) SPECIFY SAFETY GLASS FOR WINDOW ADJACENT TO THE NEW | | STAIRWAY (TOP AND BOTTOM). SEC. R308.4.(7) AND SEC. | | R308.4(8). | | (***NOTE: SAME RESPONSE TO ITEM #4(A) ABOVE APPLIES). | | | | *******RESPONSE TO INFORMATION SUBMITTED: | | (A) 3M SAFETY FILM INFORMATION SUBMITTED: NEED TO | | PROVIDE PROOF THAT FILM WAS TESTED IN ACCORDANCE WITH | | CPSC 16 CFR 1201 AS REQUIRED BY SEC. R308.3.1 OF 2010 | | FBC-RESIDENTIAL. | | | | ***IMPORTANT: PLEASE CONFIRM WITH HISTORIC IF 3M SAFETY | | FILM IS ALLOWED. | | | | | | | | *******************NEW COMMENT: | | | | 1- PROVIDE HURRICANE SHUTTERS COMPLETE INSTALLATION | | SCHEDULE. YOU MAY USE THE CITY SAMPLE OR PROVIDE ALL | | THE INFORMATION ON A DIFFERENT FORMAT AS LONG AS ALL | | THE REQUIRED INFORMATION IS PROVIDED. NEED THIS | | INFORMATION TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OS SEC. R301 OF 2010 FBC-RESIDENTIAL. | | (SHUTTERS ARE NOT REQUIRED. SEE ITEM 1(A) ABOVE. | | | | | | ***NOTE: PLEASE PROVIDE A RESPONSE LETTER ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-04-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-04-30 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-04-30 |
Time |
14:15 |
Sent To |
|
|
Notes |
2014-04-30 15:58:08 | RESIDENTIAL (R3) REVISION SECOND CHECKLIST. | | CODE: 2010 FBC. | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: | | A) PROPOSED CUSTOM DOOR "A" SPECIFIED ON PLANS. | | (***NOTE: THE DOOR DOESN'T HAVE TO BE IMPACT BECAUSE OF | | THE 25% EXCEPTION ON SEC. 606.4 OF 2010 FBC-EXISTING | | BUILDING. A PRODUCT APPROVAL IS STILL REQUIRED FOR ALL | | NEW DOORS. HISTORIC DOESN'T WAIVE THIS REQUIREMENT). | | | | B) SIMPSON CONNECTOR A4 SPECIFIED ON ANCHOR SCHEDULE. | | FLORIDA PRODUCT APPROVAL FL 5550 IS NOT LISTED ON THE | | FLORIDA PRODUCT APPROVAL WEBSITE FOR THE 2010 CODE. | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ALL PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS | | TO FBC. | | (***NOTE: ONLY THE FLAT ROOF NOA 13-0529.14 SUBMITTED | | WAS REVIEWED BY THE ENGINEER). | | | | 3- FLAT ROOF INFORMATION SUBMITTED: | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS (2 | | COPIES) AS REQUIRED BY GENERAL LIMITATION #7 ON PAGE 19 | | AND PAGE 27 OF NOA 13-0529.14 SUBMITTED. NEED THE | | CALCULATIONS TO MEET THE DESIGN PRESSURES OF SEC. | | R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL. | | | | 4- A)SPECIFY SAFETY GLASS FOR WINDOW ADJACENT TO THE | | SPA. SEC. R308.4(6). | | (***NOTE: HISTORIC DOESN'T WAIVE LIFE SAFETY ISSUES. | | THE LIFE SAFETY CONDITION WAS CREATED BY THE NEW | | ADDITION. PLEASE REVIEW SEC. 1104 AND SEC. 1105 OF THE | | 2010 FBC-EXISTING BUILDING TO ADDRESS THE NEW LIFE | | SAFETY ISSUES). | | | | B) SPECIFY SAFETY GLASS FOR WINDOWS ADJACENT TO THE NEW | | STAIRWAY (TOP AND BOTTOM). SEC. R308.4.(7) AND SEC. | | R308.4(8). | | (***NOTE: SAME RESPONSE TO ITEM #4(A) ABOVE APPLIES). | | | | | | ***NOTE: PLEASE PROVIDE A RESPONSE LETTER ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 | 2014-04-22 10:39:44 | R14 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-03-20 |
|
|
Cont ID |
|
Sent By |
JGOMEZ |
Date |
2014-03-20 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-03-20 |
Time |
15:01 |
Sent To |
|
|
Notes |
2014-03-20 16:09:59 | REVISION, BUILDING REVIEW COMMENTS. | | CODE; 2010 FBC. | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: | | A) PROPOSED CUSTOM/IMPACT DOOR "A" SPECIFIED ON PLANS. | | | | B) PROPOSED CAST-CRETE 8F8-1B BEAM AS SHOWN ON | | FOUNDATION PLAN. | | | | C) FLAT ROOF. | | ***NOTE: CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS | | GOING TO BE INSTALLED. AND, PROVIDE SIGNED AND SEALED | | RAS 117 CALCULATIONS IF THE APPROVED ASSEMBLY DOESN'T | | MEET THE DESIGN PRESSURES REQUIRED BY SEC. R301 OF 2010 | | FBC-RESIDENTIAL. | | | | D) SIMPSON CONNECTOR A4 SPECIFIED ON ANCHOR SCHEDULE. | | FLORIDA PRODUCT APPROVAL FL11506 IS NOT LISTED ON THE | | FLORIDA PRODUCT APPROVAL WEBSITE FOR THE 2010 CODE. | | | | 2- ENGINEER TO REVIEW AND APPROVE IN WRITING (NOT | | SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED | | BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC. | | | | 3- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | INSTALLATION OF THE SCREEN ENCLOSURE. OR PROVIDE | | COMPLETE INFORMATION UNDER A SEPARATE PERMIT. SEC. | | 107.3.5.3 CITY AMENDMENTS. | | | | 4- A) SPECIFY SIZES OF THE ROOF DRAIN SCUPPERS AND | | DOWNSPOUTS. SEC. R903.4. | | | | B) SPECIFY OVERFLOW DRAINS AND SCUPPERS SIZE AND | | LOCATION AS REQUIRED BY SEC. R903.4.1. | | | | 5- SPECIFY HOW THE WATER FROM THE NEW ROOF IS GOING TO | | BE CONTROLLED SO IT DOESN'T GO TO THE NEIGHBOR'S | | PROPERTY. SEC. R401.3. THE WATER CAN'T BE DIVERTED TO | | THE NEIGHBORS PROPERTY. | | | | 6- SPECIFY ROOF SLOPE. SEC. R905.11. | | | | 7- PROVIDE HANDRAILS AS REQUIRED BY SEC. R311.7.7. | | | | 8- A)SPECIFY SAFETY GLASS FOR WINDOW ADJACENT TO THE | | SPA. SEC. R308.4(6). | | | | B) SPECIFY SAFETY GLASS FOR WINDOW ADJACENT TO THE NEW | | STAIRWAY (TOP AND BOTTOM). SEC. R308.4.(7) AND SEC. | | R308.4(8). | | | | 9- SPECIFY NEW PORCH ROOF CROSS VENTILATION. SEC. R806. | | | | 10- A) CLARIFY WHERE IS SECTION 2/S-1 TAKEN AT?. AND B) | | REMOVE STAIRS ON EAST SIDE IF THEY ARE NOT GOING TO BE | | BUILT. DON'T CROSS OUT BY PEN. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 11- SHEET S-2: | | A) REVISE/CLARIFY INSTALLATION OF SIMPSON CONNECTOR A9 | | (SIMPSON SP6) SPECIFIED ON SECTION 1/S-2. THIS IS AN | | STUD TO PLATE CONNECTOR, NOT JOIST CONNECTOR. OR | | PROVIDE COMPLETE ENGINEERING ANALYSIS SHOWING HOW THIS | | CONNECTOR WILL WORK AS PROPOSED. SEC. 107.2.1.3 CITY | | AMENDMENTS. | | | | B) SPECIFY HOW LONG ARE THE 1/2" J-BOLTS SPECIFIED ON | | SECTION 1/S-2 TO FASTEN THE 2X8 P.T. SILL TO THE 8" | | GROUT FILLED BOND BEAM OF THE STEM WALL. SEC. 107.2.1 | | CITY AMENDMENTS. | | | | C) SPECIFY CONNECTORS AT THE ENDS OF 3-PLY VERSALAM LVL | | BEAMS SHOWN ON PLANS AT ALL THREE EXTERIOR WALLS AND | | THE INTERIOR BEAM HOLDING THE ROOF JOISTS. SEC. 107.2.1 | | CITY AMENDMENTS. | | | | D) SPECIFY FINISH FLOOR DECKING AND FINISH CEILING AND | | FASTENING. SEC. 107.2.1 CITY AMENDMENTS. | | | | 12- SHEET S-3: | | A) REVISE EXPOSURE . BUILDING EXPOSURE IS "C" NOT "B". | | SEC. R301.2.1.4.3 | | | | B) REVISE DESIGN PRESSURES FOR ALL ROOF ZONES. ALSO, | | REVISE THE DOORS/WINDOWS DESIGN PRESSURES. SEC. | | R301.2.1.4.3. | | | | C) REVISE EXISTING BUILDING CODE NOTE: THIS IS NOT | | ALTERATION LEVEL 2. THIS IS AN ADDITION. SEC. 407 OF | | 2010 FBC-EXISTING BUILDING. | | | | | | ***NOTE: PLEASE PROVIDE A RESPONSE LETTER ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2014-06-06 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-06-06 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-05-22 |
Time |
14:05 |
Sent To |
I |
|
Notes |
2014-06-06 09:38:25 | IT WAS NOT UNTIL YESTERDAY AFTERNOON THAT THE EC CAME | | IN TO THE OFFICE TO CORRECT THE PLANS. THE CORRECTED | | PLANS WERE STAMPED AND PROCESSED. | 2014-05-22 14:48:16 | UPON THE THIRD REVIEW, THERE IS STILL ELECTRICAL | | VIOLATIONS AND DISCREPANCIES. I CONTACTED THE | | ELECTRICAL CONTRACTOR TO DISCUSS THESE ITEMS AND HE | | WILL STOP IN 5/23/14 TO CLARIFY THESE ISSUES. | 2014-05-19 18:05:34 | RETURNED TO SMALL DENIED "R" FILE IS INCOMPLETE |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2014-04-22 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-04-22 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-04-22 |
Time |
10:16 |
Sent To |
B |
|
Notes |
2014-04-22 10:39:18 | NO ELECTRICAL SHEET OR SPECS OF ANY KIND WERE SUBMITTED | | FOR APPROVAL. BELOW IS A COPY OF THE NOTES FROM THE | | PREVIOUS REVIEW WHICH HAS BEEN IGNORED. | | | | ELECTRICAL REVIEW WAS DENIED DUE TO THE FOLLOWING: | | 1.ELECTRICAL DRAWINGS COMPLYING WITH ALL OF THE | | REQUIREMENTS OF THE NEC SHALL BE SUBMITTED FOR REVIEW | | AND ACCEPTANCE. | | THE NEC HAS SPECIFIC OUTLET, SWITCHING AND LIGHTING | | PLACEMENT REQUIREMENTS THAT HAVE TO BE COMPLIED WITH. | | THERE ARE SPECIFIC REQUIREMENTS ASSOCIATED WITH THE SPA | | AS WELL THAT COME INTO PLAY AND SHALL BE ADDRESSED. | | LITERATURE ON THE PROPOSED SPA SHALL ACCOMPANY THE | | SUBMITTAL. | | NEC 680.43(B) HAS LIMITATIONS ON THE CEILING FAN ABOVE | | THE SPA. | | FOR ANY QUESTIONS OR COMMENTS ON THIS REVIEW, PLEASE | | CONTACT: | | MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER, PX3353 | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | PH: (561) 805-6718, EMAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-03-11 |
|
|
Cont ID |
|
Sent By |
MALBERAN |
Date |
2014-03-11 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-03-11 |
Time |
15:52 |
Sent To |
B |
|
Notes |
2014-03-11 16:22:17 | ELECTRICAL REVIEW WAS DENIED DUE TO THE FOLLOWING: | | 1.ELECTRICAL DRAWINGS COMPLYING WITH ALL OF THE | | REQUIREMENTS OF THE NEC SHALL BE SUBMITTED FOR REVIEW | | AND ACCEPTANCE. | | THE NEC HAS SPECIFIC OUTLET, SWITCHING AND LIGHTING | | PLACEMENT REQUIREMENTS THAT HAVE TO BE COMPLIED WITH. | | THERE ARE SPECIFIC REQUIREMENTS ASSOCIATED WITH THE SPA | | AS WELL THAT COME INTO PLAY AND SHALL BE ADDRESSED. | | LITERATURE ON THE PROPOSED SPA SHALL ACCOMPANY THE | | SUBMITTAL. | | NEC 680.43(B) HAS LIMITATIONS ON THE CEILING FAN ABOVE | | THE SPA. | | FOR ANY QUESTIONS OR COMMENTS ON THIS REVIEW, PLEASE | | CONTACT: | | MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER, PX3353 | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | PH: (561) 805-6718, EMAIL: [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
P |
Date |
2014-10-03 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-10-03 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-10-03 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2014-08-12 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-08-12 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-08-12 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2014-04-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-04-30 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-04-30 |
Time |
11:32 |
Sent To |
|
|
Notes |
2014-04-17 14:47:45 | NEW SHEETS SUBMITTED. JG. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2014-03-10 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-03-10 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-03-10 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2014-10-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-10-03 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-10-03 |
Time |
17:11 |
Sent To |
|
|
Notes |
2014-10-03 17:12:34 | RECEIVED RE-SUBMITAL FROM HISTORIC. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2014-08-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-08-21 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-08-12 |
Time |
17:57 |
Sent To |
|
|
Notes |
2014-08-12 17:57:49 | TO JG DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2014-06-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-06-24 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-06-19 |
Time |
14:26 |
Sent To |
|
|
Notes |
2014-06-24 14:27:18 | REVISION RESUBMITTAL SENT TO JULIO'S DESK FOR REVIEW. | | JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-06-06 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-06-06 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-05-15 |
Time |
|
Sent To |
PC |
|
Notes |
2014-06-06 09:44:49 | PROCESSED AND SENT TO READY RACK | | | 2014-05-16 08:37:30 | SENT TO J. GOMEZ FOR REVIEW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
F |
Date |
2014-04-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-04-30 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-04-17 |
Time |
14:51 |
Sent To |
|
|
Notes |
2014-04-17 14:51:59 | RESUBMITTAL SENT TO R14 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-03-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-03-20 |
Time |
17:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-03-10 |
Time |
11:21 |
Sent To |
|
|
Notes |
2014-03-11 11:21:46 | SENT TO ELECTRCAL BOX. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2014-10-03 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-10-03 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-10-03 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2014-08-12 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-08-12 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-08-12 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2014-05-09 |
|
|
Cont ID |
|
Sent By |
dmalone |
Date |
2014-05-09 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
dmalone |
Date |
2014-05-08 |
Time |
13:58 |
Sent To |
|
|
Notes |
2014-05-09 13:59:17 | LANDSCAPE PERMIT APPLICATION RCVD 5/8/14. PERMIT | | 14050276 ISSUED 5/9/14. | | SEE CONDITIONAL APPROVAL LETTER LINKED TO BLDG 7 CO | | (14030350,55,67,78,86,95,400). PRIOR TO ISSUANCE OF CO, | | MUST PASS FINAL IRRIGATION AND LANDSCAPE INSPECTIONS. | | DM 5/9/14 | | X1562 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2014-04-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-04-30 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-04-30 |
Time |
11:33 |
Sent To |
|
|
Notes |
2014-04-21 15:15:04 | 4/21/14 | 2014-04-17 14:47:16 | NEW SHEETS SUBMITTED. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-03-10 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-03-10 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-03-10 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|