Plan Review Details - Permit 14030258
Plan Review Stops For Permit 14030258
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-04-09 Cont ID  
Sent By jwitmer Date 2014-04-09 Time 13:41 Rev Time 0.00
Received By jwitmer Date 2014-04-09 Time 13:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-03-25 Cont ID  
Sent By jwitmer Date 2014-03-25 Time 06:33 Rev Time 0.00
Received By jwitmer Date 2014-03-25 Time 05:46 Sent To  
Notes
2014-03-25 06:33:29BUILDING PLAN REVIEW
 REVISION: 14030258
 PERMIT: 14010760
 ADD: 1741 PALM BEACH LAKES # E224
 CONT: ANDERSON MOORE
 TEL: (561) 401-1349/ LEXI
  
 1ST REVIEW
 DATE: TUESDAY/ MARCH 25/ 2014
 ACTION: DENIED
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1) THE PLANS SHOW ADDITIONAL WORK, AN INCREASE FROM THE
 ORIGINAL SCOPE OF WORK COVERED UNDER THIS PERMIT AND
 THE REVISION FORM STATES NO INCREASE IN VALUE. W P B
 ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES. ON
 BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL, AND
 PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, A
 FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN
 ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE
 APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 2) THE LS1 SHEET SHOWS NEW WALLS BEING ADDED AND YET
 THE PLANS INDICATE THE COMMON PATH OF TRAVEL THROUGH
 THE WALL, NOT REFLECTING THE TRUE COMMON PATH OF
 TRAVEL. 2010 FBC-B 1014.3.
  
 3) SHEET A100 THE ACCESSIBLE DRESSING ROOM INDICATES
 THE SIZE OF THE BENCH TO BE 3'-6" X 1'-0", H= 17".
 PLEASE REFER TO THE 2010 FL ACCESSIBILITY CODE SECTION
 903.3 SIZE.
 BENCHES SHALL HAVE SEATS THAT ARE 42 INCHES (1065 MM)
 LONG MINIMUM AND 20 INCHES (510 MM) DEEP MINIMUM AND 24
 INCHES (610 MM) DEEP MAXIMUM.
  
 4A) SHEET A100 THE ACCESSIBLE DRESSING ROOM BENCH DOES
 NOT INDICATE HOW COMPLIANCE WITH SECTION 903.4 WILL BE
 ACHIEVED. 903.4 BACK SUPPORT.
 THE BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE
 AFFIXED TO A WALL. BACK SUPPORT SHALL BE 42 INCHES
 (1065 MM) LONG MINIMUM AND SHALL EXTEND FROM A POINT 2
 INCHES (51 MM) MAXIMUM ABOVE THE SEAT SURFACE TO A
 POINT 18 INCHES (455 MM) MINIMUM ABOVE THE SEAT
 SURFACE. BACK SUPPORT SHALL BE 21/2 INCHES (64 MM)
 MAXIMUM FROM THE REAR EDGE OF THE SEAT MEASURED
 HORIZONTALLY.
  
 4B) 903.6 STRUCTURAL STRENGTH.
 ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS
 USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS
 (1112 N) IS APPLIED AT ANY POINT ON THE SEAT, FASTENER,
 MOUNTING DEVICE, OR SUPPORTING STRUCTURE.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-04-07 Cont ID  
Sent By skennedy Date 2014-04-07 Time 11:34 Rev Time 0.00
Received By skennedy Date 2014-04-07 Time 11:34 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-04-01 Cont ID  
Sent By skennedy Date 2014-04-01 Time 09:46 Rev Time 0.00
Received By skennedy Date 2014-04-01 Time 09:46 Sent To  
Notes
2014-04-01 09:48:46SEE THE BUILDING PLAN REVIEW NOTES. IT IS UNCLEAR WHAT
 THE PARTITION ARRANGEMENT IS PROPOSED TO BE. PLEASE
 COORDINATE ALL DRAWINGS TO SHOW CONSISTENCY.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-03-17 Cont ID  
Sent By scaldero Date 2014-03-17 Time 13:00 Rev Time 0.00
Received By scaldero Date 2014-03-17 Time 12:59 Sent To  
Notes
2014-03-17 13:00:19PERMIT #14030258
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED BY EMAIL ([email protected])
 ([email protected]) OR IN WRITING (FAX: 561-804-4774) AND
 APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT
 500 NORTH DIXIE HIGHWAY.
  
 ENTRY DOORS: THUMB-TURN LOCK TO BE EQUIPPED WITH A
 LOCK/UNLOCK INDICATOR.
  
 EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED WITH
 SIGNS OR STENCILING READING FIRE BARRIER-PROTECT ALL
 OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN
 HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE
 SPACED NOT MORE THAN 15 FEET ON CENTER.
  
 PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN
 STOREROOM TO ENSURE EGRESS PATH REQUIREMENTS ARE
 MAINTAINED AT ALL TIMES.
  
 AN APPROVED WRITTEN EMERGENCY PLAN FOR THE EMERGENCY
 EGRESS OF OCCUPANTS IS REQUIRED PRIOR TO OCCUPANCY. ALL
 EMPLOYEES SHALL BE INSTRUCTED AND PERIODICALLY DRILLED
 WITH RESPECT TO THEIR DUTIES UNDER THE PLAN.
  
 EMPLOYEES SHALL BE PERIODICALLY TRAINED OR INSTRUCTED
 IN THE USE OF PORTABLE FIRE EXTINGUISHERS.
  
 SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO THE
 FIRE ALARM AND SPRINKLER SYSTEM.
  
 WHERE MUSIC SYSTEMS ARE BEING INSTALLED IN TENANT
 SPACES: THE SPEAKER SYSTEM WILL NEED TO BE TESTED
 AGAINST THE FIRE ALARM SYSTEM TO ENSURE THAT THE
 MINIMUM REQUIRED DECIBEL LEVELS OF THE FIRE ALARM
 SYSTEM ARE BEING MET. PENDING RESULTS OF FIELD
 INSPECTION/FIRE ALARM TEST, ADDITIONAL REQUIREMENTS MAY
 BE NEEDED.
  
 SUE ELLEN CALDERON
 FIRE INSPECTOR & INVESTIGATOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-04-09 Cont ID  
Sent By jwitmer Date 2014-04-09 Time 13:41 Rev Time 0.00
Received By jwitmer Date 2014-04-07 Time 11:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-04-01 Cont ID  
Sent By skennedy Date 2014-04-01 Time 09:48 Rev Time 0.00
Received By skennedy Date 2014-03-07 Time 17:35 Sent To  
Notes
2014-03-10 17:42:41B19