Plan Review Stops For Permit 14030190 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-04-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-04-02 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-04-02 |
Time |
14:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-03-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-13 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-12 |
Time |
18:24 |
Sent To |
|
|
Notes |
2014-03-13 15:00:35 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE NEW | | EXTERIOR DOORS AND WINDOWS AS REQUIRED BY DCA RULE | | 9N-3. | | | | 2) SHOW COMPLIANCE WITH FBC R301.2.1.2, WHICH REQUIRES | | LARGE MISSILE PROTECTION FOR GLAZED OPENINGS THAT ARE | | PART OF THE BUILDING ENVELOPE. IF STORM PANELS WILL BE | | INSTALLED, SUBMIT TWO COPIES OF PRODUCT APPROVALS, AN | | INSTALLATION SCHEDULE AND A KEY PLAN. | | | | 3) THE PRODUCT APPROVALS ARE REQUIRED BY BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY | | AMENDMENTS 107.3.4.1 | | | | 4) TO HELP SPEED THE REVIEW PROCESS, PLEASE SUBMIT A | | RESPONSE LETTER INDICATING HOW EACH REVIEW COMMENT HAS | | BEEN ADDRESSED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-04-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-04-02 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-04-02 |
Time |
14:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2014-03-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-13 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-13 |
Time |
10:34 |
Sent To |
|
|
Notes |
2014-03-13 10:38:48 | RED-LINED PLANS |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2014-04-10 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-04-10 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-04-10 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2014-03-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-03-11 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-03-11 |
Time |
11:23 |
Sent To |
|
|
Notes |
2014-03-10 16:26:19 | 3/10/14 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-04-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-04-10 |
Time |
17:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-31 |
Time |
09:35 |
Sent To |
|
|
Notes |
2014-04-01 09:35:28 | ****EXPEDITED**** | | | | R20 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-03-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-13 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-06 |
Time |
17:40 |
Sent To |
|
|
Notes |
2014-03-06 17:41:37 | SENT TO R6 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2014-04-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-04-02 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-04-02 |
Time |
14:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2014-03-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-13 |
Time |
07:19 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-13 |
Time |
07:19 |
Sent To |
|
|
Notes |
2014-03-13 09:39:24 | 2010 FBC | | | | DENIED BY MECHANICAL | | | | 1) NO MECHANICAL PLANS WERE SUBMITTED. A NEW MINI-SPLIT | | A/C IS SHOWN ON THE ELECTRICAL PLANS. A DRYER VENT AND | | BATHROOM EXHAUSTS ARE SHOWN ON THE PLANS. A MECHANICAL | | PERMIT IS REQUIRED. CITY AMENDMENTS 105.1 | | | | 2) SUBMIT TWO COPIES OF EQUIPMENT SIZING CALCULATIONS | | FOR THE NEW MINI-SPLIT THAT WILL BE INSTALLED IN THE | | SUN ROOM. FBCR M1401.3 | | | | | | 3) SUBMIT TWO COPIES OF THE ARI SHEET FOR THE | | MINI-SPLIT. CITY AMENDMENTS 107.2.1.3 | | | | 4) PROVIDE DISCONNECTS FOR THE MINI-SPLIT CONDENSING | | UNIT AND AIR HANDLER AS REQUIRED BY THE 2008 NEC | | 440.11. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2014-03-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-12 |
Time |
18:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-12 |
Time |
18:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-03-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-03-11 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-03-11 |
Time |
11:23 |
Sent To |
B |
|
Notes |
|
|