Plan Review Details - Permit 14030130
Plan Review Stops For Permit 14030130
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-03-15 Cont ID  
Sent By rmcdouga Date 2014-03-15 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2014-03-15 Time 11:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-03-07 Cont ID  
Sent By rmcdouga Date 2014-03-07 Time 09:33 Rev Time 0.00
Received By rmcdouga Date 2014-03-07 Time 09:33 Sent To  
Notes
2014-03-07 09:37:432010 FBC
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS FOR THE CHILD BARRIER FENCE THAT WILL BE
 INSTALLED AS SPECIFIED ON THE PLANS. FBC R4101.17
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-03-07 Cont ID  
Sent By rmcdouga Date 2014-03-07 Time 09:32 Rev Time 0.00
Received By rmcdouga Date 2014-03-07 Time 09:32 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2014-03-07 Cont ID  
Sent By rmcdouga Date 2014-03-07 Time 09:37 Rev Time 0.00
Received By rmcdouga Date 2014-03-07 Time 09:37 Sent To  
Notes
2014-03-07 09:38:37NO GAS EQUIPMENT IS SHOWN ON PLANS.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-03-05 Cont ID  
Sent By fmittner Date 2014-03-05 Time 11:19 Rev Time 0.00
Received By fmittner Date 2014-03-05 Time 11:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-03-17 Cont ID  
Sent By rmcdouga Date 2014-03-17 Time 16:53 Rev Time 0.00
Received By rmcdouga Date 2014-03-14 Time 11:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-03-07 Cont ID  
Sent By rmcdouga Date 2014-03-07 Time 10:48 Rev Time 0.00
Received By rmcdouga Date 2014-03-05 Time 16:13 Sent To  
Notes
2014-03-06 16:15:12POOL BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-03-17 Cont ID  
Sent By rmcdouga Date 2014-03-17 Time 16:53 Rev Time 0.00
Received By rmcdouga Date 2014-03-15 Time 11:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-03-07 Cont ID  
Sent By rmcdouga Date 2014-03-07 Time 09:38 Rev Time 0.00
Received By rmcdouga Date 2014-03-07 Time 09:38 Sent To  
Notes
2014-03-07 10:47:522010 FBC
  
 DENIED BY PLUMBING
  
 1) SPECIFY THE POOL PUMP THAT WILL BE USED ON THE
 PLANS. CITY AMENDMENTS 107.2.1 AND FBC R4101.6.3
  
  
 2) SUBMIT TWO COPIES OF THE SPECIFICATIONS AND THE PUMP
 CURVE DIAGRAM SHOWING THE MAXIMUM FLOW RATE IN GALLONS
 PER MINUTE FOR THE POOL PUMP. FBC R4101.6.3
  
 3) THE TDH CALCULATION THAT WAS ATTACHED TO THE PLAN
 INDICATES AN INTELLIFLO VS+SVRS. THE MAXIMUM FLOW RATE
 FOR THIS PUMP IS 145 GPM WITH A TDH OF 50'. THE WATER
 VELOCITY AT THIS FLOW RATE IN 2.5" PIPE IS MORE THAN
 THE 8 FT/SEC MAXIMUM ALLOWED FOR SUCTION PIPING. FBC
 R4101.6.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2014-03-05 Cont ID  
Sent By fmittner Date 2014-03-05 Time 11:20 Rev Time 0.00
Received By fmittner Date 2014-03-05 Time 11:20 Sent To  
Notes
***NONE***