Plan Review Details - Permit 14021070
Plan Review Stops For Permit 14021070
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-03-13 Cont ID  
Sent By jgomez Date 2014-03-13 Time 13:45 Rev Time 0.00
Received By jgomez Date 2014-03-13 Time 13:45 Sent To  
Notes
2014-03-13 13:49:27APPROVED WITH PROVISO:
 TALKED TO AARON. NEED TO USE TU PLUS UNDERLAYMENT WITH
 THE ELASTOFLEX SA-V OVER PLYWOOD JOINTS ON ROOF ZONE #3
 TO MEET THE -135PSF MAX. DESIGN PRESSURES. ROOF ZONE #3
 IS 4' X 4' MIN. SEE LIMITATION 5.5.2.3.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-02-28 Cont ID  
Sent By jgomez Date 2014-02-28 Time 18:04 Rev Time 0.00
Received By jgomez Date 2014-02-28 Time 17:39 Sent To  
Notes
2014-02-28 18:13:26RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- A) BORAL ROOFING UNDERLAYMENT FL14317-R4 SUBMITTED
 DOESN'T WORK FOR THE PROPOSED INSTALLATION OF CONCRETE
 TILE WITH FOAM ADHESIVE. SEE LIMITATION 5.5.2 ON PAGE 3
 OF 9. NEED TO MEET THE DESIGN PRESSURES REQUIRED BY
 SEC. R301 OF 2010 FBC-RESIDENTIAL.
  
 B) PROVIDE CURRENT BORAL ROOFING UNDERLAYMENT PRODUCT
 APPROVAL. PRODUCT APPROVAL SUBMITTED NOW IS THE
 FL14317-R4. NEED TO PROVIDE THE CURRENT PRODUCT
 APPROVAL FL14317-R5.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-03-13 Cont ID  
Sent By jgomez Date 2014-03-13 Time 13:44 Rev Time 0.00
Received By jgomez Date 2014-03-13 Time 13:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-28 Cont ID  
Sent By jgomez Date 2014-02-28 Time 17:39 Rev Time 0.00
Received By jgomez Date 2014-02-28 Time 17:39 Sent To  
Notes
***NONE***