Plan Review Details - Permit 14020950
Plan Review Stops For Permit 14020950
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2014-08-04 Cont ID  
Sent By rmcdouga Date 2014-08-04 Time 16:23 Rev Time 0.00
Received By rmcdouga Date 2014-08-04 Time 16:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2014-07-31 Cont ID  
Sent By rmcdouga Date 2014-07-31 Time 18:07 Rev Time 0.00
Received By rmcdouga Date 2014-07-31 Time 17:55 Sent To  
Notes
2014-07-31 18:26:452010 FBC
  
 DENIED BY BUILDING
  
 1) ONLY ONE TRUSS PLACEMENT PLAN FOR THE MODEL 'F'
 GABLE WAS SUBMITTED. A MINIMUM OF TWO SETS IS REQUIRED.
 CITY AMENDMENTS 107.1
  
 2) NO TRUSS PLACEMENT PLANS FOR THE MODEL 'F' HIP (
 ALTERNATE ROOF FRAMING PLAN) OR TRUSS DRAWINGS WERE
 SUBMITTED. SUBMIT TWO SETS OF SIGNED AND SEALED TRUSS
 PLACEMENT PLANS AND TRUSS DRAWINGS AS REQUIRED BY CITY
 AMENDMENTS 107.1 AND DCA RULE 9N-3.
  
 3) THE TRUSS PLACEMENT PLANS AND DRAWINGS FOR THE MODEL
 'F' HIP ( ALTERNATE ROOF FRAMING PLAN) FROM THE
 DELEGATED ENGINEER ARE REQUIRED TO BE REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD. CITY AMENDMENTS
 107.3.4.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2014-06-19 Cont ID  
Sent By rmcdouga Date 2014-06-19 Time 10:19 Rev Time 0.00
Received By rmcdouga Date 2014-06-19 Time 10:19 Sent To  
Notes
2014-06-19 10:25:11THE NEW TRUSS DRAWINGS NEED TO BE REVIEWED AND APPROVED
 BY THE ARCHITECT. THE ARCHITECT'S SHOP DRAWING REVIEW
 STAMP IS NOT ON THE DRAWINGS. CITY AMENTMENTS 107.3.4.1

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2014-05-22 Cont ID  
Sent By rmcdouga Date 2014-05-22 Time 09:33 Rev Time 0.00
Received By rmcdouga Date 2014-05-22 Time 09:33 Sent To  
Notes
2014-05-22 10:36:162010 FBC
  
 TRUSS DRAWINGS FOR MODEL F - HIP AND GABLE ROOF OPTIONS
 ARE DENIED
  
 1) THE TRUSS ENGINEER IS REQUIRED TO SIGN BY HAND THE
 LICENSEE'S HANDWRITTEN SIGNATURE ( FACSIMILES ARE NOT
 ACCEPTABLE ) ON ALL DRAWINGS, PLANS, REPORTS, OR
 DOCUMENTS PREPARED OR ISSUED BY THE LICENSEE AND BEING
 FILED FOR PUBLIC RECORD. SEE FAC 61G15-23.002 THE
 SIGNATURE ON THE TRUSS COVER OR INDEX SHEET IS A
 FACSIMILE.
  
 2) TWO SETS OF TRUSS DRAWINGS AND TRUSS LAYOUTS ARE
 REQUIRED TO BE SUBMITTED FOR PLANS THAT ARE BEING
 MASTERED PER CITY AMENDMENTS 107.1 ONE SET WILL BE
 FILED FOR PUBLIC RECORD AND THE OTHER SET WILL BE
 RETURNED TO THE CONTRACTOR FOR USE IN THE FIELD.
  
 3) THE ITEMS THAT WERE NOTED BY THE ARCHITECT ON THE
 TRUSS DRAWINGS AND LAYOUTS WILL NEED TO BE CORRECTED
 BEFORE THEY WILL BE APPROVED BY THE BUILDING
 DEPARTMENT. CITY AMENDMENTS 107.2.1 AND FBCR 802.1.6
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2014-05-22 Cont ID  
Sent By rmcdouga Date 2014-05-22 Time 07:11 Rev Time 0.00
Received By rmcdouga Date 2014-05-22 Time 07:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2014-04-22 Cont ID  
Sent By rmcdouga Date 2014-04-22 Time 08:32 Rev Time 0.00
Received By rmcdouga Date 2014-04-22 Time 07:11 Sent To Z
Notes
2014-04-22 08:15:022010 FBC
  
 DENIED BY BUILDING
  
 1) THE TRUSS PLACEMENT PLAN AND TRUSS DRAWING COVER
 SHEET THAT WERE SUBMITTED DO NOT HAVE THE ORIGINAL WET
 SIGNATURE OF THE ENGINEER AS REQUIRED BY FAC
 61G15-23.002 FOR DOCUMENTS THAT ARE SUBMITTED FOR
 PUBLIC RECORD.
  
 2) THE TRUSS PLACEMENT PLAN IS TOO SMALL. CITY
 AMENDMENT 107.2.1.4 TO THE FBC REQUIRES PLANS SUBMITTED
 FOR RECORD TO BE A MINIMUM 1/8 INCH SCALE.
  
 3) THE TRUSS PLACEMENT PLAN THAT WAS SUBMITTED IS FOR
 THE ALTERNATE ROOF FRAMING PLAN. THERE ARE TWO
 DIFFERENT ROOF FRAMING PLANS SPECIFIED ON SHEET S-1 OF
 THE PLAN. THE FIRST ONE HAS A GABLE END AT THE BACK OF
 THE STRUCTURE AND THE ALTERNATE ONE HAS A HIP ROOF AT
 THE BACK. PLEASE SUBMIT BOTH TRUSS PACKAGES OR REVISE
 THE PLANS TO REMOVE THE GABLE OPTION. CITY AMENDMENTS
 107.2.1
  
 4) THERE IS A DISCREPANCY BETWEEN THE STRUCTURAL ROOF
 FRAMING PLAN AND THE TRUSS PLACEMENT PLAN AND TRUSS
 DRAWINGS THAT WAS NOTED ON THE SHOP DRAWING REVIEW. THE
 STRUCTURAL ROOF PLANS SHOW THE HIP AND JACK TRUSSES AT
 THE FRONT BEARING ON THE FRONT WALL OF THE STRUCTURE
 AND THE TRUSS PLACEMENT PLAN AND TRUSS DRAWINGS HAVE
 THEM ATTACHED TO A HIP GIRDER TRUSS THAT WILL CARRY
 THIER LOAD AND TRANSFER IT TO THE SIDE WALLS. THE TRUSS
 ANCHORS SPECIFIED FOR THIS TRUSS ARE NOT ADEQUATE FOR
 THIS ADDITIONAL LOADING. THIS WILL NEED TO BE CORRECTED
 BEFORE THE MASTER PERMIT CAN BE APPROVED. CITY
 AMENDMENTS 107.2.1 AND FBC R802.1.6.5
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-03-11 Cont ID  
Sent By rmcdouga Date 2014-03-11 Time 18:24 Rev Time 0.00
Received By rmcdouga Date 2014-03-11 Time 18:24 Sent To  
Notes
2014-03-11 18:25:30STILL NEED TRUSS PACKAGE AND PRODUCT APPROVALS, SEE
 PREVIOUS REVIEW COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-02-25 Cont ID  
Sent By rmcdouga Date 2014-02-25 Time 18:25 Rev Time 0.00
Received By rmcdouga Date 2014-02-25 Time 18:25 Sent To  
Notes
2014-02-25 18:31:502010 FBC / MASTER MODEL "F"
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF A GENERIC MODEL "F" SITE PLANS
 THAT INCLUDE SURFACE WATER DRAINAGE FOR THE MASTER.
 SITE SPECIFIC SITE PLANS WITH DRAINAGE SHOWN AND
 SURVEYS WILL BE REQUIRED FOR EACH PERMIT APPLIED FOR
 UNDER THE MASTER. FBC R401.3 ( NO SHEET A-0.1 WAS
 SUBMITTED.)
  
 2) REVISE WIND DESIGN DATA ON SHEET S-2 TO REFERENCE
 THE 2010 FBC AND A WIND SPEED OF 170 MPH VULT/132 MPH
 VASD EXPOSURE C AND CHANGE ALL OTHER REFERENCES FROM
 THE 2007 BUILDING CODE TO THE 2010 FBC. FBC R 301.2.1
  
 3) ON SHEET S-2, REVISE NOTE 2, B TO REFERENCE ACI
 315-08. THE 2008 EDITION IS THE ONE REFERENCED BY THE
 2010 FBCR OR JUST SPECIFY THE CURRENT EDITION. FBCR
 CHAPTER 43
  
 4) SUBMIT TWO SETS OF TRUSS DRAWINGS AND LAYOUTS FOR
 ASCE7-10, 170 MPH AND EXPOSURE C THAT HAVE BEEN SIGNED
 AND SEALED BY THE TRUSS ENGINEER AND REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE
 MODEL "F" STRUCTURE HIP AND GABLE ROOF OPTIONS. FBC
 R802.1.6.1 THESE ARE REQUIRED TO BE SUBMITTED AND
 REVIEWED FOR THE MASTER.
  
 5) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE 8" WIDE
 CAST-CRETE LINTELS. THE FLORIDA COVER SHEET IS OKAY.
 NOA NO. 12020913 FOR THE 8" WIDE LINTELS WAS NOT
 SUBMITTED. THE ONE THAT WAS IS FOR THE 4, 6 AND 12"
 WIDE LINTELS. DCA RULE 9N-3
  
 6) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE
 STRUCTURAL CONNECTORS (IE TRUSS ANCHORS) AS REQUIRED BY
 DCA RULE 9N-3.
  
 7) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY
 AMENDMENTS 107.3.4.1
  
 8) THE PLANS SHOW ONE AND A HALF BATHROOMS AND THE
 BUILDING INPUT SUMMARY REPORT HAS ZERO BATHROOMS.
 PLEASE CALRIFY WHY THERE IS A DIFFERENCE. CITY
 AMENDMENTS 107.2.1
  
 9) THE WINDOW SCHEDULE SPECIFIES 24 EH AND 2843 EH
 SINGLE HUNG WINDOWS. WHAT DOES EH MEAN? THE 24 EH
 SINGLE HUNG WINDOW IS SPECIFIED AS THE BEDROOM EGRESS
 WINDOWS. A 24-5 SH WINDOW IS WHICH IS 37" X 56" IS
 REQUIRED TO MEET EGRESS REQUIREMENTS. PLEASE CLARIFY.
  
 PLEASE SUBMIT A RESPONSE LETTER THAT DETAILS HOW EACH
 OF THE REVIEW COMMENTS WAS ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-02-25 Cont ID  
Sent By rmcdouga Date 2014-02-25 Time 18:26 Rev Time 0.00
Received By rmcdouga Date 2014-02-25 Time 18:25 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-04-22 Cont ID  
Sent By jroach Date 2014-04-22 Time 11:47 Rev Time 0.00
Received By jroach Date 2014-04-22 Time 10:36 Sent To  
Notes
2014-04-22 11:47:38PROVISO
  
 1. PER HPB CASE NO. 07-06, INFILL CONSTRUCTION IS
 LIMITED FOR HISTORIC PRESERVATION PURPOSES, TO THE
 NORTHWEST HISTORIC DISTRICT ONLY. INDIVIDUAL INFILL
 CONSTRUCTION PROJECTS MUST BE REVIEWED BY THE HISTORIC
 PRESERVATION BOARD FOR CONTEXTUAL COMPATIBILITY.
  
 QUESTIONS/COMMENTS, CONTACT FRIEDERIKE MITTNER, CITY
 HISTORIC PRESERVATION PLANNER, AT [email protected] OR
 (561) 822-1457.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-04-22 Cont ID  
Sent By rmcdouga Date 2014-04-22 Time 08:32 Rev Time 0.00
Received By rmcdouga Date 2014-03-10 Time 17:49 Sent To  
Notes
2014-03-11 17:50:23SENT TO R MCDOUGAL

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-02-25 Cont ID  
Sent By rmcdouga Date 2014-02-25 Time 18:26 Rev Time 0.00
Received By rmcdouga Date 2014-02-25 Time 18:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-02-25 Cont ID  
Sent By rmcdouga Date 2014-02-25 Time 18:25 Rev Time 0.00
Received By rmcdouga Date 2014-02-25 Time 18:25 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2014-04-22 Cont ID  
Sent By rmcdouga Date 2014-04-22 Time 11:47 Rev Time  
Received By jroach Date 2014-04-22 Time 08:33 Sent To  
Notes
2014-04-22 11:47:16PROVISO
  
 1. MASTER PERMIT FOR STRUCTURE ONLY! EACH PROPERTY
 SHALL BE PERMITTED SEPARATELY AND SHALL PROVIDE
 SITE-SPECIFIC SITE PLANS, LANDSCAPE PLANS, ETC.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL
 PLANNER, AT [email protected] OR (561) 822-1448.
  