Plan Review Stops For Permit 14020878 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2014-05-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-16 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-16 |
Time |
10:55 |
Sent To |
|
|
Notes |
2014-05-16 10:56:28 | SEE PROVISO ON PLAN, APPLICANT HAS AGREED TO SUBMIT | | REVISION UPON COMPLETION OF DESIGN. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-11 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-11 |
Time |
14:50 |
Sent To |
|
|
Notes |
2014-05-11 14:38:56 | SECOND REVIEW: | | | | THE APPLICATION PROPOSES TO COMBINE TWO EXISTING | | RESIDENCES UPON SEPARATE PLATTED LOTS INTO ONE. | | | | PROVIDE AN UP TO DATE SURVEY FOR PROPOSED IMPROVEMENTS | | AS PREVIOUSLY REQUESTED. THIS IS REQUESTED TO | | COMPLIMENT THE SITE PROVIDED AND TO FUFILL THE PLAN | | SUBMITTAL REQUIREMENTS OF FBC 107.2.5 SITE PLAN AND | | FBC-110.7, DRAINAGE: | | | | FBC 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | GRADES AND, AS APPLICABLE, FLOOD HAZARD AREAS, | | FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE | | DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE | | SURVEY. IN THE CASE OF DEMOLITION, THE SITE PLAN SHALL | | SHOW CONSTRUCTION TO BE DEMOLISHED AND THE LOCATION AND | | SIZE OF EXISTING STRUCTURES AND CONSTRUCTION THAT ARE | | TO REMAIN ON THE SITE OR PLOT. THE BUILDING OFFICIAL IS | | AUTHORIZED TO WAIVE OR MODIFY THE REQUIREMENT FOR A | | SITE PLAN WHEN THE APPLICATION FOR PERMIT IS FOR | | ALTERATION OR REPAIR OR WHEN OTHERWISE WARRANTED.. | | | | FBC-110.7 SUPPLY A DRAINAGE DESIGN. NEW CONSTRUCTION | | ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL HISTORIC | | SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT | | PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN | | COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE | | POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES. | | SUPPLY A DRAINAGE DESIGN. | | | | THE ENERGY FORM SUBMITTED DID NOT COMPLY WITH THE | | MINIMUM REQUIREMENTS OF FBC 107.3.5.1.6 ENERGY | | CALCULATIONS - PROVIDE AN ENERGY SUBMITTAL COMPLIANT | | WITH FBC-E 103. A SIZING CALCULATION IS REQUIRED PER | | FBC-E 403.2.5. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | | | | | | 2014-04-22 14:00:44 | SENT TO ENG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-03-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-03-19 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-03-16 |
Time |
13:32 |
Sent To |
ENG |
|
Notes |
2014-03-16 13:56:55 | THE APPLICATION PROPOSES TO COMBINE TWO EXISTING | | RESIDENCES UPON SEPARATE PLATTED LOTS INTO ONE. PROVIDE | | A UNITITY OF TITLE AND AN UP TO DATE SURVEY FOR | | PROPOSED IMPROVEMENTS. | | ADDITIONAL INFORMATION IA AVAILABLE AT :HTTP://WPB.ORG/ | | WP-CONTENT/UPLOADS/SITES/7/2012/05/2011- | | 11-14-16-09-54-APPLICATIONFORUNITYOFTITLE.PDF | | FBC 107.3.5.1.6 ENERGY CALCULATIONS - PROVIDE AN ENERGY | | SUBMITTAL COMPLIANT WITH FBC-E 103 | | FBC 107.3.4 - PRODUCT APPROVALS FOR THOSE PRODUCTS | | WHICH ARE REGULATED BY DCA RULE 9N-3 ARE TO BE REVIEWED | | AND APPROVED IN WRITING BY THE STRUCTURAL DESIGNER OF | | RECORD. SPECIFICALLY, PROVIDE EVIDENCE OF REVIEW OF | | ROOFING, WINDOW, SHUTTER, SIDING, AND DOOR SUBMITTALS | | BY FREDRICK SCHAFFER, PE. | | FBC-110.7 SUPPLY A DRAINAGE DESIGN. NEW CONSTRUCTION | | ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL HISTORIC | | SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT | | PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN | | COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE | | POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES. | | SUPPLY A DRAINAGE DESIGN. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-04-22 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-04-22 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-04-22 |
Time |
08:24 |
Sent To |
ENG |
|
Notes |
2014-04-22 10:00:10 | ALL PREVIOUS COMMENTS HAVE BEEN PROPERLY ADDRESSED. | | ELECTRICAL REMINDER: | | AS PER NEC 240.24, ELECTRICAL PANELS OR OCPD?S CAN?T BE | | OVER THE STEPS OF A STAIRWAY OR INSIDE A CLOTHES | | CLOSET. CONFIRM THAT VEST 2 WILL NOT VIOLATE THIS | | REQUIREMENT. | | IMPORTANT NOTICE: | | UNLESS INSTALLED & COMPLETED BY THE ELECTRICAL | | CONTRACTOR OF RECORD, SEPARATE PERMIT WILL BE REQUIRED | | FOR ALL LOW VOLTAGE, DATA AND/OR COMMUNICATION SYSTEM | | INSTALLATIONS. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-03-17 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-03-17 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-03-17 |
Time |
15:12 |
Sent To |
B |
|
Notes |
2014-03-17 16:24:06 | THE FIRST ELECTRICAL REVIEW FAILED AND THE FOLLOWING | | DEFICIENCIES WERE NOTED: | | 1. STATE/INDICATE. THE APPLICABLE CODE ON THE -PLANS | | (2008 EDITION OF THE NATIONAL ELECTRICAL CODE) | | 2 PAGE NUMBERS AS SUBMITTED DO NOT MATCH THE DRAWING | | INDEX. | | 3. ELECTRICAL NOTES 1 & ELECTRICAL SPECIFICATIONS 4 | | CONFLICT WITH EACH OTHER. | | 4. NEC HAS SPECIFIC OUTLET PLACEMENTS REQUIREMENTS ON | | SECTION 210.52 THAT SHALL BE OBSERVED. | | 5. NEC 210.8 HAS SPECIFIC GFCI REQUIREMENTS WHICH HAVE | | TO BE FOLLOWED. | | 6. NEC 210.12 HAS ARC-FAULT REQUIREMENTS | | 7. NEC 406.11 ADDRESSES TAMPER-RESISTANT DEVICES | | 8. SHALL SUBMIT PANEL SCHEDULES FOR BOTH, PANELS A & B | | 9. INCLUDE THE COMPASS ARROW ON THE ELECTRICAL DRAWINGS | | 10 THE LOCATION OF THE 5 CONDENSING UNITS SHALL BE | | INDICATED ON THE DRAWINGS. | | | | IT IS NOT THE INTENT OF THIS REVIEW TO PROVIDE A PUNCH | | LIST FOR YOUR DESIGN PROFESSIONAL, BUT IF THERE ARE ANY | | QUESTIONS, PLEASE DO NOT HESITATE TO CONTACT: | | MIKE ALBARRAN, ELECTRICAL PLANS REVIEWER CITY OF WEST | | PALM BEACH | | PH: (561) 805-6718 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2014-05-03 |
|
|
Cont ID |
|
Sent By |
MGONZALE |
Date |
2014-05-03 |
Time |
|
Rev Time |
0.25 |
Received By |
mgonzale |
Date |
2014-05-03 |
Time |
|
Sent To |
B |
|
Notes |
2014-05-03 10:56:09 | PROVISO: | | | | NO DOMESTIC WATER AND SEWER IS SHOWN ON PLANS. PROVIDE | | INFORMATION AT NEXT REVISION | | | | CONTACT. | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2014-03-28 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-03-19 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
mgonzale |
Date |
2014-03-28 |
Time |
|
Sent To |
Z |
|
Notes |
2014-03-28 12:54:30 | PROVIDE LOCATION OF WATER AND SEWER SERVICES | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2014-02-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-02-24 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-02-24 |
Time |
14:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-05-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-16 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-15 |
Time |
17:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-11 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-04-16 |
Time |
12:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-03-28 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-03-28 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-02-24 |
Time |
17:08 |
Sent To |
|
|
Notes |
2014-02-24 17:09:00 | SENT TO R14 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2014-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-11 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-11 |
Time |
14:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2014-03-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-03-16 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-03-16 |
Time |
13:25 |
Sent To |
|
|
Notes |
2014-03-16 13:26:58 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. | | THE PLANS ARE TO BE STAMPED AND RECEIPT PROVIDED. | | CONTACT 561 233 5100. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2014-05-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-16 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-16 |
Time |
10:55 |
Sent To |
|
|
Notes |
2014-05-16 10:55:26 | SEE PROVISO ON PLAN, APPLICANT HAS AGREED TO SUBMIT | | REVISION UPON COMPLETION OF DESIGN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2014-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-11 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-11 |
Time |
14:53 |
Sent To |
|
|
Notes |
2014-05-11 14:56:23 | SECOND REVIEW: | | | | THE ENERGY SUBMITTAL MUST CONTAIN AN EQUIPMENT SIZING | | CALCULATION PER FBC-E 403.2.5 | | FBC 107.3.5.1.6 ENERGY CALCULATIONS - PROVIDE AN ENERGY | | SUBMITTAL COMPLIANT WITH FBC-E 103 | | FBC- 107.3.5.3 PROVIDE AN EQUIPMENT SCHEDULE TO LIST | | THE PROPOSED SYSTEM EQUIPMENT TO BE CHECKED TO COMPLY | | WITH THE SIZING CALCULATION. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2014-03-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-03-19 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-03-16 |
Time |
13:57 |
Sent To |
|
|
Notes |
2014-03-16 14:03:50 | FBC 107.3.5.1.6 ENERGY CALCULATIONS - PROVIDE AN ENERGY | | SUBMITTAL COMPLIANT WITH FBC-E 103 | | FBC- 107.3.5.3 ? PROVIDE A MECHANICAL PLAN TO SHOW BATH | | EXHAUST PER FBC-R M15 AND UPDATE THE EQUIPMENT SCHEDULE | | TO LIST THE PROPOSED SYSTEM EQUIPMENT. SHOW THE | | LOCATIONS OF THE A/C CONDENSING UNITS. SHOW KITHEN AND | | BATH EXHAUST. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2014-05-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-16 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-16 |
Time |
10:55 |
Sent To |
|
|
Notes |
2014-05-16 10:54:53 | SEE PROVISO ON PLAN, APPLICANT HAS AGREED TO SUBMIT | | REVISION UPON COMPLETION OS DESIGN. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2014-05-15 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-15 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-15 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2014-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-11 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-11 |
Time |
12:30 |
Sent To |
|
|
Notes |
2014-05-11 14:51:48 | SECOND REVIEW: | | | | FBC 107.3.5.3 RESIDENTIAL - PROVIDE THE LOCATION OF THE | | PROPOSED WATER METER AND THE SEWER TIE-IN. THE PLUMBING | | WASTE DIAGRAM SHOULD SHOW A CONNECTION TO THE SEWER AND | | THE BUILDING SEWER TO THE SEWER TIE-IN. PLEASE NOTE: | | THERE IS A NOTE FROM THE ENGINEER THAT THE PLUMBING | | WASTE RISER IS FOR REFERENCE AND THE PLUMBER IS TO | | PROVIDE SHOP DRAWINGS FOR REVIEW BY ENGINEER OF RECORD. | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-03-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-03-16 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-03-16 |
Time |
14:06 |
Sent To |
E |
|
Notes |
2014-03-16 14:21:11 | FBC 107.3.5.3 RESIDENTIAL - PROVIDE THE LOCATION OF THE | | PROPOSED WATER METER AND THE SEWER TIE-IN. THE PLUMBING | | WASTE DIAGRAM SHOULD SHOW A CONNECTION TO THE SEWER AND | | THE BUILDING SEWER TO THE SEWER TIE-IN. PLEASE NOTE: | | THERE IS A NOTE FROM THE ENGINEER THAT THE PLUMBING | | WASTE RISER IS FOR REFERENCE AND THE PLUMBER IS TO | | PROVIDE SHOP DRAWINGS FOR REVIEW BY ENGINEER OF RECORD. | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2014-05-15 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-05-15 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-05-15 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-02-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-02-24 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-02-24 |
Time |
14:29 |
Sent To |
|
|
Notes |
|
|