Plan Review Stops For Permit 14020551 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2014-09-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-09-20 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-09-20 |
Time |
11:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2014-08-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-08-06 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-08-06 |
Time |
13:00 |
Sent To |
|
|
Notes |
2014-08-06 16:08:37 | BUILDING PROVISO: | | | | SHEET AE101B & AE101F THE MAIN ENTRY GATE BETWEEN THE | | FITNESS CENTER & BISTRO WILL NEED TO MEET BOTH | | REQUIREMENTS FOR EGRESS: | | | | 2010 FBC-B 424.1.3.1.9. ACCESS THROUGH THE BARRIER OR | | FENCE FROM DWELLING UNITS, SUCH AS HOMES, APARTMENTS, | | MOTEL ROOMS AND HOTEL ROOMS, SHALL BE THROUGH | | SELF-CLOSING, SELF-LATCHING LOCKABLE GATES OF 48 INCH | | (1219 MM) MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH | | THE LATCH LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM | | THE BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM) | | BELOW THE TOP OF THE GATE ON THE POOL SIDE. IF THE | | SELF-CLOSING, SELF-LATCHING GATE IS ALSO SELF-LOCKING | | AND IS OPERATED BY A KEY LOCK, ELECTRONIC OPENER OR | | INTEGRAL COMBINATION LOCK, THEN THE OPERABLE PARTS OF | | SUCH LOCKS OR OPENERS SHALL BE 34 INCHES MINIMUM (864 | | MM) AND 48 INCHES MAXIMUM (1219 MM) ABOVE THE FINISHED | | FLOOR OR GROUND. GATES SHALL OPEN OUTWARD AWAY FROM THE | | POOL AREA. | | | | 2010 FBC-B 1008.1.10 PANIC AND FIRE EXIT HARDWARE. | | DOORS SERVING A GROUP H OCCUPANCY AND DOORS SERVING | | ROOMS OR SPACES WITH AN OCCUPANT LOAD OF 50 OR MORE IN | | A GROUP A OR E OCCUPANCY SHALL NOT BE PROVIDED WITH A | | LATCH OR LOCK UNLESS IT IS PANIC HARDWARE OR FIRE EXIT | | HARDWARE. | | | | THE GATES WILL NEED TO BE DESIGNED SO PANIC HARDWARE | | (1008.1.10) WILL BE INSTALLED ON THE INTERIOR SIDE OF | | THE GATE AND THE EXTERIOR SIDE WILL HAVE A RELEASING | | MECHANISM LOCATED AT 54 INCHES ABOVE THE | | DECK(424.1.1.9) . THE RELEASING MECHANISM WILL NEED TO | | BE TIED INTO THE PANIC HARDWARE RELEASING MECHANISM. | | NOTE THE CONCERNS OF A CHILD ON THE EXTERIOR SIDE OF | | THE GATE WILL NOT BE ABLE TO ACTIVATE THE PANIC | | HARDWARE AND GAIN ENTRY INTO THE POOL AREA. THE GATE | | WILL HAVE TO HAVE SELF CLOSING AND SELF LATCHING | | HARDWARE. | | | | THIS TYPE OF SITUATION WILL NEED TO BE ADDRESSED ON ALL | | GATES AND OR DOORS THAT LEAD TO THE POOL DECK FROM THE | | EXTERIOR. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | DEVELOPMENT SERVICES HOME PAGE | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-06-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-06-30 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-06-30 |
Time |
05:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-03-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-03-14 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-03-14 |
Time |
15:09 |
Sent To |
|
|
Notes |
2014-03-14 16:40:50 | BUILDING PLAN REVIEW | | REVISION: 14020551 | | MASTER PERMIT: 13070299 | | ADD: 8100 IBIS BLVD | | CONT: THE WEITZ CO. | | TEL: (561 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 1ST REVIEW | | DATE: FRIDAY MARCH 14/2014 | | ACTION: DENIED | | | | 1) PLEASE PROVIDE A NARATIVE FOR EACH SHEET WHAT | | REVISIONS ARE BEING COVERED UNDER THIS SUBMITTAL. | | PLEASE LIGHTEN ALL PREVIOUS REVISIONS SO ONLY THE | | NEWEST REVISIONS ARE HIGHLIGHTED. 2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, 2010 EDITION 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-06-25 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-06-25 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-06-25 |
Time |
15:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2014-03-19 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-03-19 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-03-19 |
Time |
09:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2014-09-16 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2014-09-16 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2014-09-16 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2014-08-12 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2014-08-12 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2014-08-12 |
Time |
08:14 |
Sent To |
|
|
Notes |
2014-08-12 08:16:13 | 8100 IBIS BOULEVARD | | TRACKING #14020551 | | PERMIT #13070299 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SHEET AE324: OPEN FLAME NATURAL GAS FIRE PIT NEEDS A | | FENCE/BARRIER TO PREVENT POOL DECK OCCUPANTS ON THE | | STONE WALL FROM INTENTIONALLY OR ACCIDENTALLY COMING | | INTO CONTACT WITH OPEN FLAMES AND/OR HOT GLASS ROCKS. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2014-06-27 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2014-06-27 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2014-06-27 |
Time |
10:15 |
Sent To |
|
|
Notes |
2014-06-27 11:39:19 | 8100 IBIS BOULEVARD | | TRACKING #14020551 | | PERMIT #13070299 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SHEET AS105: PLAN INDICATES A NEW GAS FIRE PIT. COULD | | NOT LOCATE ANY SHEETS DETAILING THIS NEW FEATURE. | | INDICATE THE FUEL TYPE (PROPANE, METHANE, ETC.) AND HOW | | THIS FLAME WILL BE GUARDED FROM OCCUPANTS. NOTE: | | OUTDOOR FIREPLACES SHALL BE PROVIDED WITH AN APPROVED | | SPARK ARRESTER, SCREEN OR DOOR. | | | | SHEET AE101F: WHY HAS PANIC HARDWARE BEEN REMOVED FROM | | ALUMINUM GATE EXIT DOORS? | | | | SHEET AE101P: WHY HAS PANIC HARDWARE BEEN REMOVED FROM | | ALUMINUM GATE EXIT DOORS? | | | | SHEET EP101B: THE FIRE ALARM CONTROL PANEL IS NOW | | LOCATED IN STORAGE ROOM #B108B. DEDICATED CLEARANCES | | AND WORKING SPACE SHALL BE PROVIDED AT ALL TIMES TO | | ALLOW EXPEDIENT ACCESS TO THE CONTROL UNIT AT ALL | | TIMES. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2014-03-12 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2014-03-12 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2014-03-12 |
Time |
07:27 |
Sent To |
|
|
Notes |
2014-03-12 07:36:41 | 8100 IBIS BOULEVARD | | PERMIT #14020551 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | THE DRAWING LAYERS CONTAINING THE PREVIOUS REVISION | | CLOUDS AND PREVIOUS DELTAS NEED TO BE FROZEN TO MAKE | | THE DRAWING READABLE. | | | | PLEASE PROVIDE A NARRATIVE OR DESCRIPTION OF WHAT HAS | | CHANGED..."COORDINATION" IS NOT SPECIFIC ENOUGH. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW | | (561) 805-6730 | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2014-09-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-09-20 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-09-05 |
Time |
20:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-08-12 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2014-08-12 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2014-07-25 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-06-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-06-30 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-29 |
Time |
09:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2014-03-19 |
Time |
|
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2014-02-13 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2014-06-25 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-06-25 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-06-25 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2014-03-01 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2014-03-01 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2014-03-01 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2014-06-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-06-30 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-06-30 |
Time |
05:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-03-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-03-14 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-03-14 |
Time |
15:39 |
Sent To |
|
|
Notes |
2014-03-14 16:53:02 | PLUMBING PLAN REVIEW | | REVISION: 14020551 | | MASTER PERMIT: 13070299 | | ADD: 8100 IBIS BLVD | | CONT: THE WEITZ CO. | | TEL: (561 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 1ST REVIEW | | DATE: FRIDAY MARCH 14/2014 | | ACTION: DENIED | | | | 1) PLEASE PROVIDE A NARATIVE FOR EACH SHEET WHAT | | REVISIONS ARE BEING COVERED UNDER THIS SUBMITTAL. | | PLEASE LIGHTEN ALL PREVIOUS REVISIONS SO ONLY THE | | NEWEST REVISIONS ARE HIGHLIGHTED. 2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, 2010 EDITION 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2014-09-29 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-09-29 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-09-25 |
Time |
15:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
N |
Date |
2014-06-25 |
|
|
Cont ID |
|
Sent By |
avann |
Date |
2014-06-25 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2014-06-06 10:59:11 | 6/5/14 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2014-03-13 |
|
|
Cont ID |
|
Sent By |
avann |
Date |
2014-03-13 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2014-03-13 |
Time |
14:14 |
Sent To |
|
|
Notes |
2014-03-03 14:55:45 | 3/3/14 |
|
|