Plan Review Details - Permit 14020100
Plan Review Stops For Permit 14020100 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-02-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-26 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-26 |
Time |
06:55 |
Sent To |
|
|
Notes |
2014-02-26 07:22:06 | RED-LINED PLANS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-02-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-06 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-06 |
Time |
07:57 |
Sent To |
|
|
Notes |
2014-02-06 11:22:14 | 2010 FBC | | | | DENIED | | | | 1) BASED ON THE DRAWING THAT WAS SUBMITTED, IT APPEARS | | THAT ONE OF THE UPSTAIRS BEDROOMS DOES NOT HAVE AN | | EMERGENCY ESCAPE AND RESCUE OPENING THAT COMPLIES WITH | | FBCR310.1. PLEASE CLARIFY IF THERE IS ONE FOR THIS | | BEDROOM OR SHOW COMPLIANCE WITH THE EXCEPTION TO FBC | | EXISTING BUILDING SECTION 604.1 WHICH ALLOWS NO MORE | | THAN A 5 PERCENT REDUCTION IN THE CLEAR OPENING | | DIMENSIONS OF REPLACEMENT DOORS AND WINDOWS. | | | | 2) THE COMPONENT AND CLADDING WIND PRESSURE CHART THAT | | WAS SUBMITTED IS NOT CORRECT. THE WINDOW DIAGRAM | | DRAWING SPECIFIES THE MEAN ROOF HEIGHT AS 23 FEET AND | | THE C & C CHART HAS 20 FEET. ALL OF THE WINDOWS ARE | | INDICATED AS BEING IN WALL ZONE 5 (WITHIN 4' OF AN | | EXTERIOR CORNER). THE PRESSURES FOR A 10 SQFT WALL AREA | | IN A BUILDING LOCATED IN THE 170 MPH WIND SPEED, | | EXPOSURE C WITH A 20 ' MRH ARE POSITIVE 40.4 AND | | NEGATIVE 54.1. PLEASE CORRECT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2014-02-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-02-24 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-02-24 |
Time |
11:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-02-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-26 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-25 |
Time |
12:52 |
Sent To |
|
|
Notes |
2014-02-25 12:52:55 | TO RM DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-02-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-06 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-06 |
Time |
07:57 |
Sent To |
|
|
Notes |
2014-02-04 11:18:39 | ROUTED TO MISC 1 |
|
|
|