Plan Review Details - Permit 14020086
Plan Review Stops For Permit 14020086 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-02-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-02-13 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-13 |
Time |
16:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-02-12 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2014-02-13 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-12 |
Time |
11:05 |
Sent To |
|
|
Notes |
2014-02-12 11:06:39 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. FBC 107, TWO COMPLETE IDENTICAL COLLATED SETS | | REQUIRED. ONLY ONE SET OF ENGINEERING WAS LOCATED. | | OTHER SHEETS ARE NOT IN THE SAME ORDER SO IT CANNOT BE | | DETERMINED WHETHER OR NOT THE PLANS ARE COMPLETE. TABS | | MAY BE HELPFUL. | | | | 2. REVISE PERMIT DESCRIPTION (ON THE PERMIT | | APPLICATION) TO STATE THAT THIS IS A PRIVATE NON | | COMMERCIAL DOCK AS PER THE TRAFFIC LETTER. THE PERMIT | | DESCRIPTION IN OUR SYSTEM HAS BEEN CHANGED. IF THIS IS | | NOT ACCEPTABLE, PLEASE SHOW COMPLIANCE WITH FBC 2010 | | ACCESSIBILITY 101.1.2 AND HAVE TRAFFIC LETTER AND ANY | | OTHER AFFECTED DOCUMENTS REVISED. | | | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-02-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-02-12 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-12 |
Time |
11:08 |
Sent To |
|
|
Notes |
2014-02-05 07:25:59 | SENT TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2014-02-13 |
|
|
Cont ID |
|
Sent By |
|
Date |
2014-02-13 |
Time |
|
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2014-02-13 |
Time |
15:47 |
Sent To |
|
|
Notes |
2014-02-13 15:48:14 | 2/13/14 ZONING APPROVED. SENT TO BUILDING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2014-02-13 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2014-02-07 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2014-02-13 |
Time |
09:07 |
Sent To |
B |
|
Notes |
2014-02-07 12:14:21 | 2/7/2014 ZONING FAILED NOT IN COMPLIANCE ORD. 4492-13: | | | | | | 1. NEED COPY OF WARRANTY DEED TO PROVE OWNERSHIP OF | | PROPERTY. | | 2. SITE PLAN MUST BE DRAWN TO SCALE AND SIGNED AND | | SEALED | | 3. DOCK MUST BE USED FOR RESIDENTIAL ONLY. | | 4. LADDER IS REQUIRED FOR ALL DOCKS,MUST SHOW ON THE | | PLANS | | 5. MUST SHOW FENCE ON PLAN/SAFETY ISSUE | | 6. COMPLETE SET OF STURCTUAL PLANS FOR DOCK, MUST BE | | SIGNED AND SEALED BY A REGISTERED STUCTURAL ENGINEER | | | | ANY REVISIONS MAY RESULT IN ADDITION COMMENTS. PLEASE | | CONTACT SHIRLEY GRAHAM 561-822-1442 IF YOU HAVE | | QUESTIONS. | | |
|
|
|