Plan Review Details - Permit 14011675
Plan Review Stops For Permit 14011675 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-02-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-02-10 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-10 |
Time |
10:06 |
Sent To |
|
|
Notes |
2014-02-10 10:22:26 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 | | [email protected] | | | | FBC FLORIDA BUILDING CODE 2010 | | | | 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | FAC9N-3. FOR THE FLAT ROOF SYSTEM, PROVIDE THE FLORIDA | | STATE COVER SHEET (WWW.FLORIDABUILDING.ORG, WILL SHOW | | APPROVAL NUMBER AND STATUS). | | | | 2. THE FLAT ROOF SYSTEM HAS A DESIGN PRESSURE | | LIMITATION OF -72.5. PER SHEET S0.1 OF THE BUILDING | | PLANS, DP REQUIREMENTS ARE AS FOLLOWS: | | | | ZONE 1: -118.5 | | ZONE 2: -186.0 | | ZONE 3: -186.0 | | | | PLEASE PROVIDE ALL APPLICABLE SHEETS OF THE PRODUCT | | APPROVAL WHICH INCLUDE GENERAL INFORMATION AND | | LIMITATIONS AS WELL AS INSTALLATION INSTRUCTIONS. SEE | | PAGE 5, LIMITATION 5.6, ENHANCED FASTENING IS PERMITTED | | FOR ZONES 2 AND 3 ONLY. PLEASE SELECT AN ASSEMBLY WHICH | | MEETS THE MINIMUM DP FOR ZONE 1 OF 118.5. | | | | IF ENHANCED FASTENING IS REQUIRED FOR THE NEW ASSEMBLY, | | PROVIDE ENGINEERING. | | | | 3. REVIEW BY DESIGNER OF RECORD REQUIRED, FBC 107. | | | | 4. THREE SETS REQUIRED AS THIS IS A THRESHOLD BUILDING, | | FBC 107. | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
P |
Date |
2014-02-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-02-21 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-19 |
Time |
17:18 |
Sent To |
|
|
Notes |
2014-02-19 17:18:54 | TO SH DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-02-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-02-21 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-10 |
Time |
10:05 |
Sent To |
|
|
Notes |
2014-02-10 10:28:23 | TO ZONING | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-02-21 |
|
|
Cont ID |
|
Sent By |
AAponte |
Date |
2014-02-20 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2014-02-11 |
Time |
|
Sent To |
|
|
Notes |
2014-02-21 09:33:49 | PROVISO: CONCRETE TILE ROOF COLOR SHALL BE CONSISTENT | | WITH COLOR APPROVED BY SITE PLAN. | 2014-02-11 10:43:00 | 2/11/2014 ZONING RECEIVED SENT TO AAPONTE |
|
|
|