Plan Review Stops For Permit 14011471 |
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-01-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-01-30 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-01-24 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2014-01-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-01-30 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-01-27 |
Time |
10:06 |
Sent To |
|
|
Notes |
2014-01-27 10:07:01 | PLUMBING PROVISO: | | AIR ADMITTANCE VALVE ON KITCHEN SINK: | | 917.3.2 RELIEF VENT. | | WHERE THE HORIZONTAL BRANCH IS LOCATED MORE THAN FOUR | | BRANCH INTERVALS FROM THE TOP OF THE STACK, | | THE HORIZONTAL BRANCH SHALL BE PROVIDED WITH A RELIEF | | VENT THAT SHALL CONNECT TO A VENT STACK OR | | STACK VENT, OR EXTEND OUTDOORS TO THE OPEN AIR. THE | | RELIEF VENT SHALL CONNECT TO THE HORIZONTAL BRANCH | | DRAIN BETWEEN THE STACK AND THE MOST DOWNSTREAM FIXTURE | | DRAIN CONNECTED TO THE HORIZONTAL BRANCH | | DRAIN. THE RELIEF VENT SHALL BE SIZED IN ACCORDANCE | | WITH SECTION 916.2 AND INSTALLED IN ACCORDANCE WITH | | SECTION 905. THE RELIEF VENT SHALL BE PERMITTED TO | | SERVE AS THE VENT FOR OTHER FIXTURES. |
|
|
|