Plan Review Details - Permit 14011386
Plan Review Stops For Permit 14011386
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-02-07 Cont ID  
Sent By jwitmer Date 2014-02-07 Time 06:24 Rev Time 0.00
Received By jwitmer Date 2014-02-07 Time 06:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-01-23 Cont ID  
Sent By jwitmer Date 2014-01-23 Time 18:15 Rev Time 0.00
Received By jwitmer Date 2014-01-23 Time 17:45 Sent To  
Notes
2014-01-23 18:00:19BUILDING PLAN REVIEW
 PERMIT: 14011386
 ADD: 1793 PALM BEACH LAKES # W411
 CONT: TO BE DETERMINED
 TEL: (561)373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURSDAY JAN. 23/2014
 ACTION: DENIED
  
 THE PERMIT APPLICATION WILL NEED TO BE UPDATED, UNDER
 THE DESCRIPTION OF WORK, ADDING STOCKROOM WALLS. PLEASE
 NOTE THIS SPACE IS A SHELL ONLY SPACE, THERE HAS NEVER
 BEEN A TENANT TO RECEIVE A CERTIFICATE OF OCCUPANCY.
 THIS IS A TENANT BUILD-OUT THAT WILL RECIEVE A
 CERTIFICATE OF OCCUPANCY.
  
  
 1) PB OUTLET MALLS:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER.
  
 2) VALUE IS LOW FOR THE AMOUNT OF WORK TO BE COMPLETED
 UNDER THE SCOPE OF THIS PERMIT. HOLD WILL BE PUT OM
 PERMIT UNTILS FEES ARE INCREASED.
  
 W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES.
 ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL,
 AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT,
 A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN
 ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE
 APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 3) PLEASE REVIEW SHEET LS01 EGRESS THRU STOCK ROOM SEE
 SECTION:
 2010 FBC-B 1014.2 EGRESS THROUGH INTERVENING SPACES.
 EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH
 THIS SECTION.
 4. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE
 ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES.
 EXCEPTIONS:
 2. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH
 STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE
 FOLLOWING ARE MET:
 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS
 THAT FOUND IN THE MAIN RETAIL AREA;
 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS
 THROUGH THE STOCKROOM;
 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE
 EGRESS SIDE; AND
 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118
 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED
 WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE
 REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA
 TO THE EXIT WITHOUT OBSTRUCTIONS.
  
 4) PLANS ARE DEFICIENT, EGRESS PATHS CAN NOT BE CHECKED
 FOR COMPLIANCE WITH 2010 FBC-B 1017.3 AISLE ACCESSWAYS
 IN MERCANTILE OCCUPANCIES.
  
 5) PLANS ARE DEFICIENT, EGRESS PATHS CAN NOT BE CHECKED
 FOR COMPLIANCE SHOW ACCESSIBLE AISLES 2010 FL
 ACCESSIBILITY CODE 403.5.1.
  
 6) PLANS DO NOT PROVIDE ENOUGH INFORMATION AS TO IF
 EITHER TENANT SPACE WILL REQUIRE DRESSING ROOMS, IF IF
 SO THEN COMPLIANCE WITH 2010 FL ACCESSIBILITY CODE
 903.4.1-5.
  
 7) PLANS ALSO FAIL TO PROVIDE COMPLIANCE WITH 2010 FL
 ACCESSIBILITY CODE 904.3.2 ,904.4.1-2.
  
 8) WITH THE OCCUPANT LOAD FOR THIS TENANT, 2 RESTROOMS
 ARE REQUIRED, ONE OF THE RESTROOMS CAN BE COUNTED WITH
 THE COMMON RESTROOMS IN BUILDING J09, THE SECOND
 RESTROOM WILL STILL NEED TO COMPLY WITH 2010 FBC-P
 403.3.1 ACCESS.
 THE ROUTE TO THE PUBLIC TOILET FACILITIES REQUIRED BY
 SECTION 403.3 SHALL NOT PASS THROUGH KITCHENS, STORAGE
 ROOMS OR CLOSETS. ACCESS TO THE REQUIRED FACILITIES
 SHALL BE FROM WITHIN THE BUILDING OR FROM THE EXTERIOR
 OF THE BUILDING. ALL ROUTES SHALL COMPLY WITH THE
 ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING
 CODE, ACCESSIBILITY. THE PUBLIC SHALL HAVE ACCESS TO
 THE REQUIRED TOILET FACILITIES AT ALL TIMES THAT THE
 BUILDING IS OCCUPIED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-02-06 Cont ID  
Sent By skennedy Date 2014-02-06 Time 18:28 Rev Time 0.00
Received By skennedy Date 2014-02-06 Time 18:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-02-04 Cont ID  
Sent By albarran Date 2014-02-04 Time 10:25 Rev Time 0.00
Received By albarran Date 2014-02-04 Time 10:20 Sent To FIRE
Notes
2014-02-04 10:25:57IN ADDITION TO THE OTHER COMMENTS FROM ALL OTHER
 TRADES, YOU SHALL INCLUDE A FULLY DETAILED ELECTRICAL
 SHEET AS THIS A TENANT BUILD OUT AND NOT SIMPLY THE
 ADDITION OF AN INTERIOR WALL. THIS SHEET SHALL INCLUDE
 ALL GFI OUTLETS WHERE REQUIRED AND COMPLIANCE WITH THE
 FBC-ENERGY CONSERVATION CODE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-02-06 Cont ID  
Sent By rferguso Date 2014-02-06 Time 13:49 Rev Time 0.00
Received By rferguso Date 2014-02-06 Time 13:49 Sent To  
Notes
2014-02-06 13:50:3702/06/14 DELIVERED TO JWITMER.
2014-02-04 10:26:26RETURNED TO BIN B 13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-07 Cont ID  
Sent By jwitmer Date 2014-02-07 Time 06:25 Rev Time 0.00
Received By jwitmer Date 2014-01-23 Time 18:15 Sent To  
Notes
2014-01-23 18:16:38B13

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2014-02-07 Cont ID  
Sent By jwitmer Date 2014-02-07 Time 06:24 Rev Time 0.00
Received By jwitmer Date 2014-02-07 Time 06:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-01-23 Cont ID  
Sent By jwitmer Date 2014-01-23 Time 18:02 Rev Time 0.00
Received By jwitmer Date 2014-01-23 Time 18:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2014-02-07 Cont ID  
Sent By jwitmer Date 2014-02-07 Time 06:24 Rev Time 0.00
Received By jwitmer Date 2014-02-07 Time 06:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-01-23 Cont ID  
Sent By jwitmer Date 2014-01-23 Time 18:03 Rev Time 0.00
Received By jwitmer Date 2014-01-23 Time 18:01 Sent To  
Notes
2014-01-23 18:02:09WITH THE OCCUPANT LOAD FOR THIS TENANT, 2 RESTROOMS ARE
 REQUIRED, ONE OF THE RESTROOMS CAN BE COUNTED WITH THE
 COMMON RESTROOMS IN BUILDING J09, THE SECOND RESTROOM
 WILL STILL NEED TO COMPLY WITH 2010 FBC-P 403.3.1
 ACCESS.
 THE ROUTE TO THE PUBLIC TOILET FACILITIES REQUIRED BY
 SECTION 403.3 SHALL NOT PASS THROUGH KITCHENS, STORAGE
 ROOMS OR CLOSETS. ACCESS TO THE REQUIRED FACILITIES
 SHALL BE FROM WITHIN THE BUILDING OR FROM THE EXTERIOR
 OF THE BUILDING. ALL ROUTES SHALL COMPLY WITH THE
 ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING
 CODE, ACCESSIBILITY. THE PUBLIC SHALL HAVE ACCESS TO
 THE REQUIRED TOILET FACILITIES AT ALL TIMES THAT THE
 BUILDING IS OCCUPIED.
  

Review Stop POLICE POLICE
Rev No 1 Status N Date 2014-02-05 Cont ID  
Sent By eschneid Date 2014-02-05 Time 21:41 Rev Time 0.00
Received By eschneid Date   Time   Sent To  
Notes
2014-02-05 21:41:33CRIME PREVENTION THROUGH ENVIRONMENTAL DESIGN
 THE CITY OF WEST PALM BEACH HAS RECOGNIZED THAT
 TRADITIONAL CRIME PREVENTION STRATEGIES ARE NOT ENOUGH
 IN TODAY'S SOCIETY AND A NEW APPROACH IS NEEDED. THE
 NAME OF THIS APPROACH IS CRIME PREVENTION THROUGH
 ENVIRONMENTAL DESIGN (CPTED). CPTED ACKNOWLEDGES THE
 MANNER IN WHICH PHYSICAL SPACE IS DESIGNED OR USED HAS
 A DIRECT BEARING ON CRIME AND SECURITY.
 THE PHYSICAL ENVIRONMENT HAS A DRAMATIC EFFECT ON OUR
 OWN BEHAVIOR AND THE WAY IN WHICH WE VIEW THE BEHAVIOR
 OF OTHERS. CPTED IS A CONCEPT SUPPORTED BY A SERIES OF
 OVERLAPPING PRINCIPLES BASED ON THE RELATIONSHIP OF THE
 BUILT ENVIRONMENT TO THE PRESENCE OR ABSENCE OF
 UNDESIRABLE BEHAVIOR. THE CPTED CONCEPT IS: "THE PROPER
 DESIGN AND EFFECTIVE USE OF THE BUILT ENVIRONMENT CAN
 LEAD TO A REDUCTION IN THE INCIDENCE AND FEAR OF CRIME
 AND IMPROVEMENT IN THE QUALITY OF LIFE BY INCORPORATING
 ACCESS CONTROL, NATURAL SURVEILLANCE AND TERRITORIAL
 DEFENSIVE TACTICS.?
 CPTED THEORY IS BASED UPON THE CONTENTION THAT
 PLANNERS, DESIGNERS, ARCHITECTS, LANDSCAPERS AND LAW
 ENFORCEMENT CAN COOPERATIVELY CREATE A 'SAFE' CLIMATE
 WITHIN A BUILT ENVIRONMENT" RIGHT FROM THE BEGINNING.
 SAFETY STRIKES AT THE VERY CORE OF WHAT IS GENERALLY
 REFERRED TO IN A COMMUNITY AS "QUALITY OF LIFE." A SAFE
 ENVIRONMENT IS ONE THAT REGULAR USERS PERCEIVE AS SAFE
 AND NON-USERS (CRIMINALS) PERCEIVE AS HIGHLY RISKY TO
 FREQUENT AND IN WHICH TO COMMIT CRIMES.
 THE WEST PALM BEACH POLICE DEPARTMENT HAS OUTLINED
 GUIDELINES WE WOULD LIKE TO SEE FOLLOWED. IN ADDITION
 TO THE GUIDELINES, WE ENCOURAGE YOU TO PLEASE ADOPT
 THESE MINIMUM STANDARDS:
  
 (1) A FULLY FUNCTIONING AND OPERATIONAL CCTV SYSTEM
 CAPABLE OF RECORDING AND RETRIEVING ON SITE, AN
 IDENTIFIABLE IMAGE TO ASSIST IN OFFENDER IDENTIFICATION
 AND APPREHENSION. MONITORS FOR THE SYSTEM SHOULD BE
 PLACED IN A MANAGER'S OFFICE OR BACK ROOM, WITH A
 MONITOR IN PUBLIC VIEW FROM THE SALES FLOOR.
 (2) CAMERA COVERAGE SHOULD BE AT SENSITIVE LOCATIONS:
 (A) DOORS THAT LEADS TO THE BACK OF HOUSE (B) HALLWAYS
 THAT LEAD TO REAR EXITS (C) SALES FLOOR (D) REGISTERS
 (LOW FOR FACIAL RECOGNITION) (E) FRONT ENTRY.
 (3) DOOR THAT LEADS TO THE BACK OF HOUSE AND EXITING
 REAR DOORS SHOULD BE ALARMED WITH A SENSOR AND VIEW
 FINDER.
 (4) SILENT PANIC ALARM UNDER EACH REGISTER, ONE IN THE
 BACK OF HOUSE WORK AREA
 (5) A SECURED DROP SAFE OR CASH MANAGEMENT DEVICE FOR
 RESTRICTED ACCESS TO MONEY/CASH RECEIPTS AT THE
 REGISTER AND A SECURED DROP SAFE OR CASH MANAGEMENT
 DEVICE IN THE STORAGE AREA.
 (6) CASH OUT AREA SHOULD BE IN THE FRONT OF THE STORE,
 CLOSE TO THE ENTRANCE.
 (7) SECURE THE REGISTERS TO THE COUNTER.
 (8) INSTALL ANTI-THEFT DEVICES INCLUDING SECURITY
 TOWERS AT ENTRANCES.
 (9) USE CONVEX MIRRORS IN CORNERS AND ANTI-THEFT TAGS
 ON MERCHANDISE.
 (10) HEIGHT MARKERS AT THE ENTRANCE AND EXIT.
 (11) EMPLOYEE ACCESS CONTROL ON ALL DOORS THAT LEAD
 INTO THE BACK.
 (12) WHERE WINDOW(S) ARE PRESENT, A CLEAR AND
 UNOBSTRUCTED VIEW FROM OUTSIDE THE STORE AND IN A
 NORMAL LINE OF SIGHT OF THE CASH REGISTER AND SALES
 TRANSACTION AREA
 (13) IF INSTALLING SWING GATE AT REGISTERS THEY SHOULD
 HAVE SIMPLE ACCESS CONTROL.
 (14) ALL SHOWCASES SHOULD HAVE LOCKS AND IN THE
 EXPENSIVE SHOWCASES, CONSIDER AN ALARM.
 (15) INTERIOR SHELVING AND DISPLAYS SHOULD BE NO HIGHER
 THAN FIVE FEET, EVEN LESS IN FRONT OF WINDOWS.
  
  
 OFFICER K. TUCKER-CARSILLO
 CRIME PREVENTION UNIT
 WEST PALM BEACH POLICE DEPT
 600 BANYAN BLVD
 WEST PALM BEACH, FL 33401
 (561) 822-1620 OFFICE
 (561) 822-1648 FAX
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2014-02-05 Cont ID  
Sent By eschneid Date 2014-02-05 Time 21:38 Rev Time 0.25
Received By eschneid Date 2014-02-05 Time 21:38 Sent To  
Notes
2014-01-27 14:41:111/27/14