Plan Review Details - Permit 14011291
Plan Review Stops For Permit 14011291
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-02-14 Cont ID  
Sent By rmcdouga Date 2014-02-14 Time 10:02 Rev Time 0.00
Received By rmcdouga Date 2014-02-14 Time 09:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-01-24 Cont ID  
Sent By rmcdouga Date 2014-01-24 Time 06:27 Rev Time 0.00
Received By rmcdouga Date 2014-01-23 Time 16:37 Sent To  
Notes
2014-01-24 07:10:192010 FBC
  
 DENIED BY BUILDING
  
 1) SPECIFY THE MEAN ROOF HEIGHT OF THE STRUCTURE AND
 THE SLOPE OF THE PITCHED ROOF. FBC R301.2.1
  
 2) SPECIFY THE SQUARE FOOTAGE OF THE SLOPED ROOF AND OF
 THE FLAT ROOF. CITY AMENDMENTS 109.3
  
 3) THE STRUCTURE IS LOCATED IN A 170 MPH VULT WIND
 SPEED AND IN EXPOSURE CATEGORY C. ACCORDING TO THE
 ROOFING SYSTEM SPECIFIED ON PAGE 28 OF NOA NO.
 13-0204.03 THAT WAS SUBMITTED THE MAXIMUM DESIGN
 PRESSURE IS -52.5 PSF, WHICH IS NOT ADEQUATE FOR THE
 CORNER AND PERIMETER ROOF AREA UPLIFT PRESSURES.
 LIMITATION #7 ON SHEET 32 OF THE NOA ALLOWS FOR
 INCREASED FASTENER DENSITIES WHEN CALCULATED USING RAS
 117 CALCULATIONS. SUBMIT TWO SETS OF SIGNED AND SEALED
 RAS 117 CALCULATIONS AS SPECIFIED IN LIMITATION # 7 OF
 THE NOA. FBC R301.2.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-01-22 Cont ID  
Sent By fmittner Date 2014-01-22 Time 15:30 Rev Time 0.00
Received By fmittner Date 2014-01-22 Time 15:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-14 Cont ID  
Sent By rmcdouga Date 2014-02-14 Time 10:02 Rev Time 0.00
Received By rmcdouga Date 2014-02-13 Time 17:35 Sent To  
Notes
2014-02-13 17:36:00CUSTOMER PUT ROOFING RESUB WITH WINDOWS
 ROUTED ON 2/13 TO RM DESK
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved