Plan Review Details - Permit 14011279
Plan Review Stops For Permit 14011279 |
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2014-01-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-01-27 |
Time |
05:57 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-01-27 |
Time |
05:30 |
Sent To |
|
|
Notes |
2014-01-27 06:02:14 | 14011279 | | INSTALATION OF NATURAL GAS LINE | | NATURAL | | 0.5 PS | | TABLE 402.4(19) | | PRESSURE DROP O.5 IN. W.C. | | SPECIFIC GRAVITY 0.60 | | METHOD: LONGEST LENGTH | | 20'-0" | | 3/4 " PE PIPE | | | | 2010 FUEL GAS PROVISO: | | 404.15.3 TRACER. | | A YELLOW INSULATED COPPER TRACER WIRE OR OTHER APPROVED | | CONDUCTOR SHALL BE | | INSTALLED ADJACENT TO UNDERGROUND NONMETALLIC PIPING . | | ACCESS SHALL BE PROVIDED | | TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE | | ABOVE GROUND AT EACH END | | OF THE NONMETALLIC PIPING . THE TRACER WIRE SIZE SHALL | | NOT BE LESS THAN 18 AWG AND | | THE INSULATION TYPE SHALL BE SUITABLE FOR DIRECT | | BURIAL. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2014-01-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-01-25 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-01-25 |
Time |
12:45 |
Sent To |
|
|
Notes |
2014-01-25 13:49:33 | FUEL GAS PLAN REVIEW | | PERMIT: 14011279 | | ADD: 816 ARDMORE RD | | CONT: APEX GAS CONTRACTORS | | TEL: (561)202-7873 | | | | 2010 FLORIDA FUEL GAS CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: SATURDAY JAN. 25/ 2014 | | ACTION: DENIED | | | | 1) SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | FBC-2010 FUEL GAS SEC. 402.2. | | | | 2) 503.4.2 SPECIAL GAS VENTS. SPECIAL GAS VENTS SHALL | | BE LISTED AND INSTALLED IN ACCORDANCE WITH THE SPECIAL | | GAS VENT MANUFACTURER?S INSTALLATION INSTRUCTIONS. | | TO PROVIDE THE MINIMUM PROXIMATY OF THE APPLIANCE TO | | WINDOWS, DOORS, INSIDE CORNERS AND ROOF OVER HANGS. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-01-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-01-27 |
Time |
06:11 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-01-27 |
Time |
05:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-01-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-01-25 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-01-25 |
Time |
12:45 |
Sent To |
|
|
Notes |
2014-01-22 14:31:06 | ROUTED TO PLUMBING LESS THAN $5000 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |