Plan Review Stops For Permit 14011176 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2014-08-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-08-22 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-08-22 |
Time |
16:37 |
Sent To |
|
|
Notes |
2014-08-22 16:42:45 | BUILDING PROVISO / APPROVED WITH EXCEPTION. | | | | SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE ROOF | | COVERING MATERIALS THAT HAVE BEEN REVIEWED AND APPROVED | | BY THE DESIGNER OF RECORD. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2014-08-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-08-21 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-08-21 |
Time |
06:38 |
Sent To |
E |
|
Notes |
2014-08-21 08:58:24 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE NON-ENGINEERED FLOOD OPENINGS SPECIFIED ON | | SHEETS A-1 AND A-4 OF THE PLANS ARE ALL LOCATED ON THE | | SAME EXTERIOR WALL. FBCR322.2.2(2)(2.1) REQUIRES A | | MINIMUM OF TWO OPENINGS ON DIFFERENT SIDES OF EACH | | ENCLOSED AREA. PROVIDE OPENINGS ON ONE OF THE OTHER | | EXTERIOR WALLS. ONLY THE "NET OPEN AREA" OF THE | | NON-ENGINEERED OPENINGS CAN BE COUNTED TOWARD THE | | REQUIRED FLOOD OPENING AREA. THE MEASUREMENT OF THE NET | | OPEN AREA MUST TAKE INTO CONSIDERATION ANY COVERINGS | | THAT HAVE SOLID OBSTRUCTIONS, SUCH AS GRILLS, FIXED | | LOUVERS OR FACEPLATES. | | | | 2) THE ROOFING PRODUCT APPROVALS THAT WERE SUBMITTED | | ARE FOR A CONCRETE DECK AND THIS PROJECT HAS A PLYWOOD | | ROOF DECK. THE PRODUCT APPROVALS ARE REQUIRED TO BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD. SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR | | THE ROOFING MATERIALS THAT WILL BE USED AS REQUIRED BY | | DCA RULE 9N-3. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2014-07-03 |
|
|
Cont ID |
|
Sent By |
RMCDOUGA |
Date |
2014-07-03 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-07-02 |
Time |
18:54 |
Sent To |
E |
|
Notes |
2014-07-03 07:32:31 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE WITH A | | REQUIRED BASE FLOOD ELEVATION OF 7' NGVD. THE ELEVATION | | FOR THE FINISH FLOOR OF THE GARAGE IS SPECIFIED ON THE | | PLANS AS 5.74', WHICH DOES NOT COMPLY WITH THE CITY'S | | FLOOD ORDINANCE (6" ABOVE BFE). BECAUSE THE ADDITION OF | | A SECOND FLOOR TO THE GARAGE IS A SUBSTANTIAL | | IMPROVEMENT THE EXISTING GARAGE IS REQUIRED TO COMPLY | | WITH THE FLOOD ORDINANCE. THE FINISH FLOOR OF THE | | GARAGE CAN BE RAISED TO 7.5' NGVD. IF THE GARAGE IS | | USED SOLELY FOR THE PARKING OF VECHICLES, THE FINISHED | | FLOOR CAN BE BELOW THE BFE AND ENGINEERED FLOOD VENTS | | OR FLOOD OPENINGS CAN BE INSTALLED IN THE WALLS OF THE | | GARAGE ( SEE FEMA TECHINICAL BULLETIN 1 / AUGUST 2008 ) | | OR SOME OTHER APPROVED METHOD MAY BE USED. | | THE NOTE ON THE NEW S-1 SHEET THAT WAS SUBMITTED | | REQUIRES THE CONTRACTOR TO VERIFY EXISTING FLOOD VENTS | | ARE PRESENT AND NOTIFY ENGINEER IF NONE ARE PRESENT. | | THIS NEEDS TO BE ADDRESSED BEFORE THE PERMIT IS ISSUED. | | SPECIFY THE SIZE AND LOCATION OF THE FLOOD OPENINGS ON | | THE PLANS. PROVIDE CALCULATIONS TO SHOW THAT REQUIRED | | AREA OF FLOOD OPENINGS HAS BEEN PROVIDED. IF ENGINEERED | | FLOOD VENTS, SUCH AS 'SMART VENTS' ARE USED SUBMIT TWO | | COPIES OF THE PRODUCT APPROVALS FOR THEM AS REQUIRED BY | | DCA RULE 9N-3. YOU WILL ALSO NEED TO SHOW THAT NO | | EQUIPMENT OR MATERIALS THAT ARE NOT FLOOD | | DAMAGE-RESISTANT IS LOCATED BELOW THE 7.5' BFE. | | | | 2) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED | | AND DATED BY THE OWNER/AGENT. THIS COMMENT WAS NOT | | ADDRESSED. | | | | 3) THE ENERGY CALCULATION FORM LISTS THE INSULATION FOR | | THE FLOOR OVER THE GARAGE AS R-21.0 AND THE SECTIONS ON | | SHEET A-6 SPECIFY R-11 BATT INSULATION. PLEASE CORRECT. | | THIS COMMENT WAS NOT ADDRESSED. | | | | 4) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | ROOFING MATERIALS THAT WILL BE USED AS REQUIRED BY DCA | | RULE 9N-3. THIS COMMENT WAS NOT ADDRESSED. | | | | 5) THE VALUE OF $23,000.00 SPECIFIED ON THE PERMIT | | APPLICATION IS TOO LOW FOR THE SCOPE OF WORK SHOWN ON | | THE PLANS. CITY AMENDMENTS 109.3 THIS COMMENT WAS NOT | | ADDRESSED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-05-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-05-29 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-05-28 |
Time |
15:56 |
Sent To |
Z |
|
Notes |
2014-05-29 11:10:58 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE WITH A | | REQUIRED BASE FLOOD ELEVATION OF 7' NGVD. THE ELEVATION | | FOR THE FINISH FLOOR OF THE GARAGE IS SPECIFIED ON THE | | PLANS AS 5.74', WHICH DOES NOT COMPLY WITH THE CITY'S | | FLOOD ORDINANCE (6" ABOVE BFE). BECAUSE THE ADDITION OF | | A SECOND FLOOR TO THE GARAGE IS A SUBSTANTIAL | | IMPROVEMENT THE EXISTING GARAGE IS REQUIRED TO COMPLY | | WITH THE FLOOD ORDINANCE. THE FINISH FLOOR OF THE | | GARAGE CAN BE RAISED TO 7.5' NGVD. IF THE GARAGE IS | | USED SOLELY FOR THE PARKING OF VECHICLES, THE FINISHED | | FLOOR CAN BE BELOW THE BFE AND ENGINEERED FLOOD VENTS | | OR FLOOD OPENINGS CAN BE INSTALLED IN THE WALLS OF THE | | GARAGE ( SEE FEMA TECHINICAL BULLETIN 1 / AUGUST 2008 ) | | OR SOME OTHER APPROVED METHOD MAY BE USED. | | | | 2) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED | | AND DATED BY THE OWNER/AGENT. | | | | 3) THE ENERGY CALCULATION FORM LISTS THE INSULATION FOR | | THE FLOOR OVER THE GARAGE AS R-21.0 AND THE SECTIONS ON | | SHEET A-6 SPECIFY R-11 BATT INSULATION. PLEASE CORRECT. | | | | 4) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | ROOFING MATERIALS THAT WILL BE USED AS REQUIRED BY DCA | | RULE 9N-3. | | | | 5) THE VALUE OF $23,000.00 SPECIFIED ON THE PERMIT | | APPLICATION IS TOO LOW FOR THE SCOPE OF WORK SHOWN ON | | THE PLANS. CITY AMENDMENTS 109.3 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-03-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-07 |
Time |
19:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-07 |
Time |
08:06 |
Sent To |
|
|
Notes |
2014-03-07 18:19:39 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE. THE | | ELEVATION CERTIFICATE ON FILE FOR THE CONSTRUCTION OF | | THE SINGLE FAMILY DWELLING, PERMIT NUMBER 02100307, | | INDICATES THAT THE TOP OF THE LOWEST FLOOR IS 7.5' | | WHICH COMPLIES WITH THE CITY'S FLOOD ORDINANCE (6" | | ABOVE BFE). | | | | 2) THE PLANS THAT WERE SUBMITTED ARE INCOMPLETE. THE | | STRUCTURAL SHEETS ARE NUMBERED S-6, S-7 AND S-8. SHEETS | | S-1 THRU S-5 ARE MISSING. SUBMIT TWO SETS OF ELEVATION | | DRAWINGS AND A SITE PLAN SHOWING THE LOCATION OF THE | | STRUCTURES ON THE LOT. CITY AMENDMENTS 107.2.1 | | | | | | 3) THE STRUCTURE IS LOCATED ON THE INTERCOASTAL | | WATERWAY MAKING IT EXPOSURE CATEGORY D. PLEASE CORRECT | | THE EXPOSURE CATEGORY AND THE WIND PRESSURES IN THE | | SCHEDULE ON SHEET S-6. FBC R301.2.1.4 | | | | 4) THE SCOPE OF WORK SHOWN ON THE PLANS IS NOT CLEAR. | | PLEASE PROVIDE A COMPLETE LIST OF THE WORK THAT IS TO | | BE DONE UNDER THIS PERMIT. CITY AMENDMENTS 107.2.1 | | | | 5) THERE ARE NOT AND GUARDS SHOWN ON THE DRAWINGS FOR | | THE STAIRS, THE WALKWAY OR THE ROOF DECK. SHOW | | COMPLIANCE WITH FBC R312. | | | | 6) SHOW COMPLIANCE WITH FBC R311.7.7 FOR THE REQUIRED | | HANDRAILS. | | | | 7) FROM THE INFORMATION PROVIDED ON SHEET S-6, IT | | APPEARS THAT NEW WINDOWS ARE BEING INSTALLED INTO NEW | | OPENINGS INTO THE GARAGE WALLS. PLEASE CLARIFY. | | | | 8) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE NEW | | EXTERIOR DOOR WITH SIDELIGHT, THE ROOFING MATERIAL THAT | | WILL BE INSTALLED ON THE GARAGE ROOF DECK AND THE | | ELEVATED WALKWAY ( PLYWOOD), THE METAL CONNECTORS, | | ANCHORS AND HANGERS, THE NEW WINDOWS AND 8" STRUCTURAL | | LINTELS AS REQUIRED BY DCA RULE 9N-3. | | | | 9) THE NEW WINDOWS WILL BE REQUIRED TO HAVE LARGE | | MISSILE IMPACT PROTECTION. FBCR 301.2.1.2 IF STORM | | PANELS ARE USED, SUBMIT TWO SETS OF PRODUCT APPROVALS | | FOR THEM. DCA RULE 9N-3 | | | | 10) PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE | | PROJECT. CITY AMENDMENTS 107.3.4.1 | | | | 11) PROVIDE BUCK DETAILS FOR THE NEW DOOR AND WINDOW | | OPENINGS. FBCR612.10.2 | | | | 12) SUBMIT THE MANUFACTURER'S LOAD TABLES FOR THE 5-14" | | X 14" MICROLAM BEAMS. FBCR 301.1 | | | | 13) UPDATE THE ACI STANDARDS SPECIFIED ON SHEET S-8 TO | | THE 2008 EDITIONS. THIS IS THE EDITION THAT IS | | REFERENCED IN THE 2010 FBC. SEE CHAPTER 43. | | | | NOTE: IN ORDER TO SPEED REVIEW TIME, PLEASE SUBMIT A | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS WAS ADDRESSED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2014-08-22 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-08-22 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-08-22 |
Time |
14:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2014-07-03 |
|
|
Cont ID |
|
Sent By |
ALBARRAN |
Date |
2014-07-03 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-07-03 |
Time |
10:49 |
Sent To |
|
|
Notes |
2014-07-03 11:37:04 | DATE: 7/3/2014 | | PROJECT: | | PERMIT#: | | CODE: 2008 EDITION OF THE NEC | | 2010 EDITION OF THE FBC | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | 3RD ELECTRICAL PLAN REVIEW | | ACTION: PROVISO | | | | 1) THE SMOKE/CARBON MONOXIDE DETECTORS SHOWN ON THE | | LANDING APPEAR TO BE OUT IN THE OPEN. NOT ONLY ARE | | THESE DEVICES NOT LISTED FOR OUTDOOR USE, BUT THEY ARE | | NOT NEEDED. | | 2) A CORRECTION/ADDITION TO "NOTE 8" TO INCLUDE THE NEC | | 314.27 REQUIREMENT STATING THAT THESE BOXES SHALL BE | | LISTED TO SUPPORT 50#. | | 3) ADDITIONAL OUTLETS REQUIRED IN THE BEDROOMS TO MEET | | THE SPACING CRITERIA OF NEC 210.52 | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2014-05-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-06-02 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-05-21 |
Time |
08:32 |
Sent To |
|
|
Notes |
2014-05-21 10:14:57 | THE FOLLOWING DEFICIENCIES WERE NOTED ON THE SECOND | | REVIEW: | | | | 1. THE SMOKE/CARBON MONOXIDE DETECTORS SHOWN ON THE | | LANDING APPEAR TO BE OUT IN THE OPEN. NOT ONLY ARE | | THESE DEVICES NOT LISTED FOR OUTDOOR USE, BUT THEY ARE | | NOT DESIGNED FOR THE PURPOSE. | | 2. A CORRECTION/ADDITION TO "NOTE 8" TO INCLUDE THE NEC | | 314.27 REQUIREMENT STATING THAT THESE BOXES SHALL BE | | LISTED TO SUPPORT 50#. | | 3. THERE SHALL BE A CARBON MONOXIDE DETECTOR OUTSIDE OF | | THE SLEEPING OF THE ROOMS AND WITHIN 10' OF THE DOOR AS | | PER FBC-R 315. | | 4. ADDITIONAL OUTLETS REQUIRED IN THE BEDROOMS TO MEET | | THE SPACING CRITERIA OF NEC 210.52. | | 5. INDICATE ON THE PLANS THE ACTUAL LOCATION OF THE | | ELECTRICAL PANELS. THERE IS A CONFLICT BETWEEN THE | | LOCATIONS INDICATED ON PAGES A-0 & E-1. | | 6. PROVIDE LOAD CALCS IN ACCORDANCE WITH NEC 220.83(B). | | 7. PROVIDE AN ACCURATE AND SITE SPECIFIC ELECTRICAL | | RISER DIAGRAM AND PANEL SCHEDULE. | | | | THESE PLANS WERE REVIEWED BY MIKE ALBARRAN, ELECTRICAL | | PLANS EXAMINER | | YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE | | FOLLOWING LINK: | | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | US.ASPX | | | | ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS | | EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER, | | AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB | | ABOVE THE SECOND PERMIT INFORMATION). | | AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR | | COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER | | PERMIT CONDITIONS. | | FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME. | | I CAN BE REACHED AT 561-805-6718 OR | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-03-05 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-03-05 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-03-05 |
Time |
09:08 |
Sent To |
|
|
Notes |
2014-03-05 09:33:48 | ELECTRICAL PLAN & PERMIT REQUIRED. IF THERE IS EXISTING | | ELECTRIC IN THE GARAGE BELOW, THERE SHALL BE A MINIMUM | | OF ONE ELECTRIC OUTLET ON THE DECK. FOR LIFE SAFETY, | | THE STAIRS LEADING TO THIS DECK SHALL BE PROPERLY | | ILLUMINATED AS WELL. | | FOR ANY QUESTIONS OR COMMENTS ON THIS REVIEW, PLEASE | | CONTACT: | | MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER, PX3353 | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | PH: (561) 805-6718, EMAIL: [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2015-05-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-05-07 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-05-07 |
Time |
16:57 |
Sent To |
|
|
Notes |
2015-05-07 16:57:31 | ****EXPEDITED**** | | TO ZONING BOX | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2014-08-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-08-22 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-07-15 |
Time |
18:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-07-03 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-07-03 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-06-17 |
Time |
13:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-06-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-06-02 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-05-20 |
Time |
17:21 |
Sent To |
E |
|
Notes |
2014-05-20 17:21:50 | SENT MALBARRAN |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-03-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-07 |
Time |
19:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-01-21 |
Time |
13:17 |
Sent To |
|
|
Notes |
2014-01-23 13:17:52 | SENT TO R8 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
N |
Date |
2014-08-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-08-21 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-08-21 |
Time |
09:54 |
Sent To |
|
|
Notes |
2014-08-21 09:53:44 | MU2014-18470 | | NO IMPACT FEES WERE DUE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2014-05-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-05-28 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-05-28 |
Time |
16:21 |
Sent To |
|
|
Notes |
2014-05-28 16:29:05 | THE NEW PLANS THAT WERE SUBMITTED INDICATE THAT | | ADDITIONAL LIVING SPACE IS BEING ADDED. WHEN THE PLANS | | HAVE BEEN APPROVED, ONE SET IS TO BE SIGNED OUT AND | | TAKEN TO PALM BEACH COUNTY FOR AN IMPACT FEE REVIEW. | | THE PLANS WITH THE PLAN REVIEW STAMP AND A COPY OF THE | | PAID IMPACT FEE RECIEPT CAN THEN BE RETURNED TO THE | | CITY BUILDING DEPARTMENT. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2014-03-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-07 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-07 |
Time |
16:49 |
Sent To |
|
|
Notes |
2014-03-07 17:17:48 | NO HABITABLE SPACE IS BEING ADDED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-05-28 |
Time |
18:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-05-28 |
Time |
17:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-05-28 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-05-28 |
Time |
16:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2014-07-17 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2014-07-17 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2014-07-17 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2014-06-23 |
|
|
Cont ID |
|
Sent By |
DKITTRED |
Date |
2014-06-23 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2014-06-23 |
Time |
12:27 |
Sent To |
|
|
Notes |
2014-06-23 13:03:36 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | 6/23/14 | | | | JUNE 17, 2014 RESUBMITTAL DID NOT ADDRESS ANY OF | | PLANNING AND ZONING'S PREVIOUS COMMENTS DATED 6/5/14. | | PLEASE ADDRESS PREVIOUS COMMENTS WHEN RESUBMITTING. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2014-05-30 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2014-05-30 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2014-05-29 |
Time |
10:32 |
Sent To |
|
|
Notes |
2014-06-05 17:07:48 | 6/5/14 NOTE TO FILE: CONNECTED BUILDINGS MEET MINIMUM 5 | | FOOT SIDE SETBACK REQUIREMENT. A SETBACK THAT JOGS WITH | | THE BUILDING HAS BEEN APPROVED, PER AV, ALLOWING THE | | STRUCTURE TO MEET THE MINIMUM TOTAL SIDE SETBACK | | REQUIREMENT OF 15 FEET. DK | | | 2014-06-05 14:47:49 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | REVISED COMMENTS 6/5/14 | | [VOID COMMENTS - 5/30/14 (UPDATED 6/2/14)] | | | | REVISED PLANS CHANGED THE PROPOSED SCOPE OF WORK AND | | REQUIRED RE-REVIEW BY ZONING. | | | | 1. DRAWINGS SHOW A CONNECTION BETWEEN THE ACCESSORY | | STRUCTURE AND PRINCIPAL STRUCTURE, HOWEVER, THIS IS NOT | | ILLUSTRATED ON THE SITE PLAN. | | | | 2. ACCESSORY APARTMENTS ARE NOT PERMITTED IN THE SF7 | | ZONING DISTRICT. PLEASE BE SURE ADDITION DOES NOT | | CONTAIN STOVE, FULL SIZE REFRIDGERATOR (UNDER | | COUNTER-STYLE REFRIGERATORS ARE PERMITTED), AND/OR | | DOUBLE STYLE SINK. FOR CLARIFICATION OF THE NEW | | ADDITION, PLANS SHOULD INDICATE THE SPACE WILL NOT BE | | USED AS AN ACCESSORY APARTMENT. | | | | 3. VERIFY OVERALL HEIGHT OF HOUSE AS DEPICTED ON THE | | PLANS. | | | | 4. PLAN INDICATES AN EXISTING RAILING AROUND THE TOP OF | | THE PRINCIPAL STRUCTURE. THE PERMIT TO INSTALL THIS | | RAILING AND ROOF IMPROVEMENTS (PERMIT NO. 13010304) HAS | | EXPIRED. PLEASE NOTE, PER THE BUILDING DIVISION, ONLY A | | 104 FINAL INSPECTION LEFT. - "THEY WILL HAVE TO APPLY | | FOR A REISSUE, BUT THEY DON'T NEED A CONTRACTOR, AND | | THE FEE WILL BE $80. THE PERMIT WILL BE ISSUED AT THE | | FRONT COUNTER IMMEDIATELY AND THE INSPECTION CAN BE | | SCHEDULED FOR THE NEXT BUSINESS DAY." | | | | ADDITIONAL COMMENTS MAY BE GENERATED BASED ON ANY | | ALTERATIONS MADE TO THE PLAN. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | 2014-05-30 12:12:21 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | 5/30/14 (UPDATED 6/2/14) | | | | REVISED PLANS CHANGED THE PROPOSED SCOPE OF WORK AND | | REQUIRED RE-REVIEW BY ZONING. | | | | 1. THE MAXIMUM SQUARE FOOTAGE OF TOTAL FLOOR AREA OF | | ALL ROOFED ACCESSORY BUILDINGS ON A PROPERTY SHALL NOT | | EXCEED 75 PERCENT OF THE GROSS FLOOR AREA OF THE | | PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA OF 1,000 | | SQUARE FEET [ZLDR SEC. 94-304(B)(1)]. THE EXPANSION OF | | THE EXISTING ACCESSORY STRUCTURE INCREASES THE TOTAL | | SQUARE FOOTAGE OF THE ACCESSORY STRUCTURE TO OVER 2,000 | | SQUARE FEET AND IS NOT PERMITTED. | | | | 2. DRAWINGS SHOW A CONNECTION BETWEEN THE ACCESSORY | | STRUCTURE AND PRINCIPAL STRUCTURE, HOWEVER, THIS IS NOT | | ILLUSTRATED ON THE SITE PLAN. BY CONNECTING THE TWO | | BUILDINGS WITH ANYTHING OTHER THAN A CANVAS AWNING ON | | THE GROUND LEVEL IS CONSIDERED ATTACHING THE BUIDLINGS | | AND THE WHOLE STRUCTURE MUST THEN COMPLY WITH PRINCIPAL | | STRUCTURE SETBACKS OF THE SF7 ZONING DISTRICTED. BASED | | ON THE SITE DIMENSIONS PROVIDED ONTHE SITE PLAN, THE | | STRUCTURES COULD NOT BE ATTACHED AND MEET THE PRINCIPAL | | STRUCTURE SETBACKS. | | | | 3. OTHER ZONING CONSIDERATIONS IF MODFICATIONS ARE | | RESUBMITTED: | | | | A. PLEASE BE SURE ANY CHANGES TO THE PLANS ARE | | REFLECTED ACCURATELY ON THE SITE PLAN. | | | | B. ACCESSORY APARTMENTS ARE NOT PERMITTED IN THE SF7 | | ZONING DISTRICT. | | | | C. VERIFY OVERALL HEIGHT OF HOUSE AS DEPICTED ON THE | | PLANS. STRUCTURE APPEARS TO BE HIGHER THAN WHAT WOULD | | HAVE ORIGINALLY BEEN PERMITTED. | | | | D. PLAN INDICATES AN EXISTING RAILING AROUND THE TOP OF | | THE PRINCIPAL STRUCTURE. THE PERMIT TO INSTALL THIS | | RAILING AND ROOF IMPROVEMENTS (PERMIT NO. 13010304) HAS | | EXPIRED. PLEASE NOTE, PER THE BUILDING DIVISION, ONLY A | | 104 FINAL INSPECTION LEFT. - "THEY WILL HAVE TO APPLY | | FOR A REISSUE, BUT THEY DON'T NEED A CONTRACTOR, AND | | THE FEE WILL BE $80. THE PERMIT WILL BE ISSUED AT THE | | FRONT COUNTER IMMEDIATELY AND THE INSPECTION CAN BE | | SCHEDULED FOR THE NEXT BUSINESS DAY." | | | | ADDITIONAL COMMENTS MAY BE GENERATED BASED ON ANY | | ALTERATIONS MADE TO THE PLAN. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-01-27 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2014-01-27 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2014-01-27 |
Time |
15:25 |
Sent To |
|
|
Notes |
2014-01-27 17:29:33 | 1/27/14 - SENT BACK TO R08. DK | | | 2014-01-27 17:28:04 | 1/27/14 - IMPROVEMENTS DO NOT EXCEED 30' AND WALKWAY | | DOES NOT EXTEND PASSED EXISTING BUILDING SETBACKS. DK | 2014-01-27 14:37:45 | 1/27/14 |
|
|