Plan Review Details - Permit 14011168
Plan Review Stops For Permit 14011168
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-03-18 Cont ID  
Sent By rmcdouga Date 2014-03-18 Time 09:34 Rev Time 0.00
Received By rmcdouga Date 2014-03-18 Time 09:34 Sent To  
Notes
2014-03-18 09:34:48CONTRACTOR SUBMITTED NEW PRODUCT APPROVALS FOR THE
 FRONT DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-03-17 Cont ID  
Sent By rmcdouga Date 2014-03-17 Time 13:33 Rev Time 0.00
Received By rmcdouga Date 2014-03-17 Time 09:37 Sent To  
Notes
2014-03-17 13:33:33PROVISO
  
 SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE NEW
 IN-SWING FRONT DOOR WHICH HAS DESIGN PRESSURES OF AT
 LEAST + 46.4, - 50.5 PSF.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-03-01 Cont ID  
Sent By rmcdouga Date 2014-03-01 Time 07:41 Rev Time 0.00
Received By rmcdouga Date 2014-02-24 Time 17:16 Sent To  
Notes
2014-02-27 19:07:262010 FBC
  
 DENIED BY BUILDING
  
 1) THE SURVEY THAT WAS SUBMITTED INCORRECTLY SPECIFIES
 THE PROPERTY AS BEING FLOOD ZONE B AND A-5. ACCORDING
 TO THE FLOOD INSURANCE RATE MAP ON FILE WITH THE CITY
 THIS PROPERTY IS LOCATED IN FLOOD ZONE B ONLY. SUBMIT
 TWO COPIES OF A CORRECTED SURVEY.
  
 2) THIS STRUCTURE IS LOCATED WITHIN 600 FEET OF THE
 INTER-COASTAL WATERWAY AND IS CONSIDERED EXPOSURE
 CATEGORY D. PLEASE CORRECT THE WIND DESIGN DATA AND THE
 WIND PRESSURES ON SHEET S1.00 AND SPECIFY THE MEAN ROOF
 HEIGHT AND ROOF SLOPE OF THE STRUCTURE ON THE PLANS.
  
 3) SHOW COMPLIANCE WITH FBC R310 FOR EMERGENCY ESCAPE
 AND RESCUE OPENINGS FOR SECOND FLOOR BEDROOMS #2 AND
 #3.
  
 4) WALL SECTION C ON SHEET A.07 APPEARS TO SHOW AN
 UN-VENTED ATTIC WITH THE INSULATION ON THE TOP CORD
 WITH NO SOFFIT VENTS FOR ATTIC VENTILATION SHOWN. THE
 ENERGY CALCULATIONS SPECIFY A VENTED ATTIC. PLEASE
 CLARIFY. IF THE ATTIC IS UN-VENTED PROVIDE TWO COPIES
 OF THE PRODUCT EVALUATIONS FOR THE SPRAY FOAM
 INSULATION THAT WILL BE USED. IF THE ATTIC IS VENTED
 SPECIFY THE SIZE AND SPACING OF THE VENTS. CITY
 AMENDMENTS 107.2.1, FBC R806
  
 5) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED
 AND DATED BY THE PREPARER AND THE OWNER/AGENT. FBC
 ENERGY CONSERVATION 405.4
  
 6) SPECIFY THE WINDOW TYPES, SIZES AND LOCATIONS ON THE
 PLANS FOR THE WINDOWS THAT WILL BE REPLACED. CITY
 AMENDMENTS 107.2.1, FBC R301.2.1, R310
  
 7) INDICATE THE WINDOWS THAT WILL BE CONNECTED TOGETHER
 WITH THE STRUCTURAL MULLIONS. CITY AMENDMENTS 107.2.1,
 FBC R301.2.1
  
 8) TAKE NOTE OF THE SOIL REPORT RECOMMENDATIONS AND
 COORDINATE INSPECTIONS WITH THE STRUCTURAL BUILDING
 INSPECTOR.
  
 9) NOTE: THE WOOD FENCE AND GATE SHOWN ON THE PLANS
 REQUIRE SEPARATE APPLICATION, PERMIT AND REVIEWS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-03-17 Cont ID  
Sent By rmcdouga Date 2014-03-17 Time 08:28 Rev Time 0.00
Received By rmcdouga Date 2014-03-17 Time 07:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-02-25 Cont ID  
Sent By rmcdouga Date 2014-02-25 Time 09:40 Rev Time 0.00
Received By rmcdouga Date 2014-02-25 Time 09:40 Sent To  
Notes
2014-02-25 09:41:18REDLINED THE PLANS.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-02-03 Cont ID  
Sent By fmittner Date 2014-02-03 Time 15:52 Rev Time 0.00
Received By fmittner Date 2014-02-03 Time 15:52 Sent To  
Notes
2014-02-04 08:34:30APPROVED WITH PROVISO THAT PRODUCT FOR ROOFING BE
 REVISED TO BARREL TILE. CONFIRMED WITH ARCHITECT
 ANTHONY HARRINGTON 568-8861 ON 2/4/14. QUESTIONS
 CONTACT FRIEDERIKE MITTNER 822-1457.
2014-01-27 14:24:221/27/14

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-03-17 Cont ID  
Sent By rmcdouga Date 2014-03-17 Time 13:33 Rev Time 0.00
Received By rmcdouga Date 2014-03-12 Time 14:58 Sent To  
Notes
2014-03-12 14:59:40INCOMING SENT TO R MCDOUGALS DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-03-01 Cont ID  
Sent By rmcdouga Date 2014-03-01 Time 07:41 Rev Time 0.00
Received By rmcdouga Date 2014-01-21 Time 17:04 Sent To  
Notes
2014-01-21 17:07:57EXPEDITED R05

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2014-03-18 Cont ID  
Sent By rmcdouga Date 2014-03-18 Time 09:29 Rev Time 0.00
Received By rmcdouga Date 2014-03-18 Time 09:29 Sent To  
Notes
2014-03-18 09:31:41MU2014-6016

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-02-24 Cont ID  
Sent By rmcdouga Date 2014-02-24 Time 17:12 Rev Time 0.00
Received By rmcdouga Date 2014-02-24 Time 17:12 Sent To  
Notes
2014-02-24 17:15:59AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE
 REQUIRED WHEN THE PLANS HAVE BEEN APPROVED BY THE CITY
 BUILDING DEPARTMENT.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-03-17 Cont ID  
Sent By rmcdouga Date 2014-03-17 Time 09:46 Rev Time 0.00
Received By rmcdouga Date 2014-03-17 Time 07:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-02-25 Cont ID  
Sent By rmcdouga Date 2014-02-25 Time 06:47 Rev Time 0.00
Received By rmcdouga Date 2014-02-24 Time 18:35 Sent To  
Notes
2014-02-24 18:35:212010 FBC
  
 DENIED BY MECHANICAL
  
 1) SUBMIT TWO SETS OF MECHANICAL PLANS FOR THE NEW
 ADDITIONS. SHOW THE LOCATIONS OF THE HEATING AND
 COOLING EQUIPMENT. SHOW THE LOCATIONS AND SIZES OF ALL
 SUPPLY AND RETURN DUCTS. SPECIFY THE GRILL SIZES AND
 CFMS AT EACH OF THE SUPPLY OUTLETS. CITY AMENDMENTS
 107.3.5.3
  
 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS THAT
 MATCHES THE EQUIPMENT SIZING CALCULATIONS. 107.2.1
  
 3) SHOW COMPLIANCE WITH FBCR M1602.4 FOR BALANCED AIR
 RETURN.
  
 4) THE PLANS SHOW THE A/C CONDENSING UNITS LOCATED 12"
 OFF THE PROPERTY LINE. PLEASE BE AWARE THAT THE HEATING
 AND COOLING EQUIPMENT IS REQUIRED TO BE LOCATED TO
 PERMIT THE MAINTENANCE AND SERVICING OF THE EQUIPMENT,
 AS WELL AS, PROVIDING THE CLEARANCES REQUIRED BY THE
 MANUFACTURER. FBCR M1401.1 AND M1401.2.
  
 5) PROVIDE THE NAME, LICENSE NUMBER AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE MECHANICAL SYSTEM DESIGN
 ON THE PLANS. CITY AMENDMENTS 107.2.1 AND FS 471.003
  
  
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-03-17 Cont ID  
Sent By rmcdouga Date 2014-03-17 Time 07:28 Rev Time 0.00
Received By rmcdouga Date 2014-03-17 Time 06:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-02-24 Cont ID  
Sent By rmcdouga Date 2014-02-24 Time 18:23 Rev Time 0.00
Received By rmcdouga Date 2014-02-24 Time 18:04 Sent To  
Notes
2014-02-24 18:31:372010 FBC
  
 DENIED BY PLUMBING
  
 1) SUBMIT TWO SETS OF A PLUMBING RISER DIAGRAM FOR THE
 ENTIRE DWELLING THAT MATCHES THE PLANS. THE ONE THAT IS
 ON SHEET E.01 IS INCOMPLETE AND ILLEGIBLE. CITY
 AMENDMENTS 107.2.1 AND 107.3.5.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2014-02-25 Cont ID  
Sent By rmcdouga Date 2014-02-25 Time 17:41 Rev Time 0.00
Received By rmcdouga Date 2014-02-25 Time 17:41 Sent To  
Notes
2014-02-25 17:46:13ROOFING PRODUCT APPROVALS SUBMITTED:
  
 1) OWENS CORNING WEATHERLOCK TILE UNDERLAYMENT NOA NO.
 12-0309.03
 2) 3M AH-160 ROOF TILE ADHESIVE
 3) SANTEFE SPANISH 'S' CLAY ROOF TILE

Review Stop Z ZONING
Rev No 1 Status P Date 2014-02-03 Cont ID  
Sent By fmittner Date 2014-02-03 Time 15:52 Rev Time 0.00
Received By fmittner Date 2014-02-03 Time 15:52 Sent To  
Notes
***NONE***