Plan Review Stops For Permit 14011168 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2014-03-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-18 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-18 |
Time |
09:34 |
Sent To |
|
|
Notes |
2014-03-18 09:34:48 | CONTRACTOR SUBMITTED NEW PRODUCT APPROVALS FOR THE | | FRONT DOOR. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-03-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-17 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-17 |
Time |
09:37 |
Sent To |
|
|
Notes |
2014-03-17 13:33:33 | PROVISO | | | | SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE NEW | | IN-SWING FRONT DOOR WHICH HAS DESIGN PRESSURES OF AT | | LEAST + 46.4, - 50.5 PSF. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-01 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-24 |
Time |
17:16 |
Sent To |
|
|
Notes |
2014-02-27 19:07:26 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE SURVEY THAT WAS SUBMITTED INCORRECTLY SPECIFIES | | THE PROPERTY AS BEING FLOOD ZONE B AND A-5. ACCORDING | | TO THE FLOOD INSURANCE RATE MAP ON FILE WITH THE CITY | | THIS PROPERTY IS LOCATED IN FLOOD ZONE B ONLY. SUBMIT | | TWO COPIES OF A CORRECTED SURVEY. | | | | 2) THIS STRUCTURE IS LOCATED WITHIN 600 FEET OF THE | | INTER-COASTAL WATERWAY AND IS CONSIDERED EXPOSURE | | CATEGORY D. PLEASE CORRECT THE WIND DESIGN DATA AND THE | | WIND PRESSURES ON SHEET S1.00 AND SPECIFY THE MEAN ROOF | | HEIGHT AND ROOF SLOPE OF THE STRUCTURE ON THE PLANS. | | | | 3) SHOW COMPLIANCE WITH FBC R310 FOR EMERGENCY ESCAPE | | AND RESCUE OPENINGS FOR SECOND FLOOR BEDROOMS #2 AND | | #3. | | | | 4) WALL SECTION C ON SHEET A.07 APPEARS TO SHOW AN | | UN-VENTED ATTIC WITH THE INSULATION ON THE TOP CORD | | WITH NO SOFFIT VENTS FOR ATTIC VENTILATION SHOWN. THE | | ENERGY CALCULATIONS SPECIFY A VENTED ATTIC. PLEASE | | CLARIFY. IF THE ATTIC IS UN-VENTED PROVIDE TWO COPIES | | OF THE PRODUCT EVALUATIONS FOR THE SPRAY FOAM | | INSULATION THAT WILL BE USED. IF THE ATTIC IS VENTED | | SPECIFY THE SIZE AND SPACING OF THE VENTS. CITY | | AMENDMENTS 107.2.1, FBC R806 | | | | 5) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED | | AND DATED BY THE PREPARER AND THE OWNER/AGENT. FBC | | ENERGY CONSERVATION 405.4 | | | | 6) SPECIFY THE WINDOW TYPES, SIZES AND LOCATIONS ON THE | | PLANS FOR THE WINDOWS THAT WILL BE REPLACED. CITY | | AMENDMENTS 107.2.1, FBC R301.2.1, R310 | | | | 7) INDICATE THE WINDOWS THAT WILL BE CONNECTED TOGETHER | | WITH THE STRUCTURAL MULLIONS. CITY AMENDMENTS 107.2.1, | | FBC R301.2.1 | | | | 8) TAKE NOTE OF THE SOIL REPORT RECOMMENDATIONS AND | | COORDINATE INSPECTIONS WITH THE STRUCTURAL BUILDING | | INSPECTOR. | | | | 9) NOTE: THE WOOD FENCE AND GATE SHOWN ON THE PLANS | | REQUIRE SEPARATE APPLICATION, PERMIT AND REVIEWS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-03-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-17 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-17 |
Time |
07:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2014-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-25 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-25 |
Time |
09:40 |
Sent To |
|
|
Notes |
2014-02-25 09:41:18 | REDLINED THE PLANS. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2014-02-03 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-02-03 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-02-03 |
Time |
15:52 |
Sent To |
|
|
Notes |
2014-02-04 08:34:30 | APPROVED WITH PROVISO THAT PRODUCT FOR ROOFING BE | | REVISED TO BARREL TILE. CONFIRMED WITH ARCHITECT | | ANTHONY HARRINGTON 568-8861 ON 2/4/14. QUESTIONS | | CONTACT FRIEDERIKE MITTNER 822-1457. | 2014-01-27 14:24:22 | 1/27/14 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-03-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-17 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-12 |
Time |
14:58 |
Sent To |
|
|
Notes |
2014-03-12 14:59:40 | INCOMING SENT TO R MCDOUGALS DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-01 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-01-21 |
Time |
17:04 |
Sent To |
|
|
Notes |
2014-01-21 17:07:57 | EXPEDITED R05 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2014-03-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-18 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-18 |
Time |
09:29 |
Sent To |
|
|
Notes |
2014-03-18 09:31:41 | MU2014-6016 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2014-02-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-24 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-24 |
Time |
17:12 |
Sent To |
|
|
Notes |
2014-02-24 17:15:59 | AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE | | REQUIRED WHEN THE PLANS HAVE BEEN APPROVED BY THE CITY | | BUILDING DEPARTMENT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2014-03-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-17 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-17 |
Time |
07:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2014-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-25 |
Time |
06:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-24 |
Time |
18:35 |
Sent To |
|
|
Notes |
2014-02-24 18:35:21 | 2010 FBC | | | | DENIED BY MECHANICAL | | | | 1) SUBMIT TWO SETS OF MECHANICAL PLANS FOR THE NEW | | ADDITIONS. SHOW THE LOCATIONS OF THE HEATING AND | | COOLING EQUIPMENT. SHOW THE LOCATIONS AND SIZES OF ALL | | SUPPLY AND RETURN DUCTS. SPECIFY THE GRILL SIZES AND | | CFMS AT EACH OF THE SUPPLY OUTLETS. CITY AMENDMENTS | | 107.3.5.3 | | | | 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS THAT | | MATCHES THE EQUIPMENT SIZING CALCULATIONS. 107.2.1 | | | | 3) SHOW COMPLIANCE WITH FBCR M1602.4 FOR BALANCED AIR | | RETURN. | | | | 4) THE PLANS SHOW THE A/C CONDENSING UNITS LOCATED 12" | | OFF THE PROPERTY LINE. PLEASE BE AWARE THAT THE HEATING | | AND COOLING EQUIPMENT IS REQUIRED TO BE LOCATED TO | | PERMIT THE MAINTENANCE AND SERVICING OF THE EQUIPMENT, | | AS WELL AS, PROVIDING THE CLEARANCES REQUIRED BY THE | | MANUFACTURER. FBCR M1401.1 AND M1401.2. | | | | 5) PROVIDE THE NAME, LICENSE NUMBER AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE MECHANICAL SYSTEM DESIGN | | ON THE PLANS. CITY AMENDMENTS 107.2.1 AND FS 471.003 | | | | | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2014-03-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-17 |
Time |
07:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-17 |
Time |
06:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2014-02-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-24 |
Time |
18:23 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-24 |
Time |
18:04 |
Sent To |
|
|
Notes |
2014-02-24 18:31:37 | 2010 FBC | | | | DENIED BY PLUMBING | | | | 1) SUBMIT TWO SETS OF A PLUMBING RISER DIAGRAM FOR THE | | ENTIRE DWELLING THAT MATCHES THE PLANS. THE ONE THAT IS | | ON SHEET E.01 IS INCOMPLETE AND ILLEGIBLE. CITY | | AMENDMENTS 107.2.1 AND 107.3.5.3 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2014-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-25 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-25 |
Time |
17:41 |
Sent To |
|
|
Notes |
2014-02-25 17:46:13 | ROOFING PRODUCT APPROVALS SUBMITTED: | | | | 1) OWENS CORNING WEATHERLOCK TILE UNDERLAYMENT NOA NO. | | 12-0309.03 | | 2) 3M AH-160 ROOF TILE ADHESIVE | | 3) SANTEFE SPANISH 'S' CLAY ROOF TILE |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-02-03 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-02-03 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-02-03 |
Time |
15:52 |
Sent To |
|
|
Notes |
|
|