Plan Review Details - Permit 14010745
Plan Review Stops For Permit 14010745 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-02-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-02-12 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-12 |
Time |
16:46 |
Sent To |
|
|
Notes |
2014-02-12 16:49:04 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. TWO SETS OF ENGINEERING SUBMITTED, FOUR REQUIRED | | (TWO DIFFERENT PERMITS, ONE SET FOR EACH PERMIT). THE | | GRAPHIC ON THE ENGINEERING DOES NOT MATCH EITHER SIGN | | ("OUTLET" IN A DIFFERENT PLACE). PLEASE PROVIDE TWO | | SETS OF ENGINEERING WHICH MATCHES THE ZONING APPROVALS | | OR SUBMIT NEW ZONING ELEVATIONS SHOWING SIGN AND | | LOCATION, FBC 107. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-02-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-02-02 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-02 |
Time |
13:16 |
Sent To |
|
|
Notes |
2014-02-02 13:17:52 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. PROVIDE ENGINEERING FOR THE PROPOSED SIGNS, FBC | | 1609. THIS IS TO INCLUDE WIND DESIGN CRITERIA. PLANS | | REFER TO ENGINEERING FOR FASTENING, BUT I WAS UNABLE TO | | LOCATE A SPECIFICATION. | | | | 2. SEE FBC 109.3, FOR PERMITTING PURPOSES, VALUATION OF | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | EXCLUDING ONLY LAND VALUE. REVISE VALUE. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2014-02-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-02-04 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-02-04 |
Time |
11:38 |
Sent To |
|
|
Notes |
2014-02-04 11:42:45 | PROVIDE DETAILS NECESSARY TO ESTABLISH COMPLIANCE WITH | | NEC 600. SHOW DISCONNECT PER NEC 600.6. THE PROVIDED | | DETAILS ARE CROSSED OUT AND MARKED "DO NOT USE." |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-02-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-02-12 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-06 |
Time |
15:52 |
Sent To |
|
|
Notes |
2014-02-07 15:52:44 | RESUBMITTAL SENT TO S. HILL'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-02-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-02-04 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-01-14 |
Time |
16:23 |
Sent To |
|
|
Notes |
2014-02-02 13:18:04 | TO SK | | | 2014-01-14 16:23:20 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2014-02-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-02-02 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-02-02 |
Time |
13:18 |
Sent To |
|
|
Notes |
2014-02-02 13:18:39 | OK PER AV | | |
|
|
|