Plan Review Stops For Permit 14010620 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2014-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-03 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-03 |
Time |
12:55 |
Sent To |
|
|
Notes |
2014-03-03 13:56:10 | THIS PERMIT IS FOR LIMITED EXPLORATORY DEMOLITION ONLY | | AS STATED IN THE DESCRIPTION OF WORK ON THE | | APPLICATION. THE SCOPE OF WORK FOR THIS PERMIT IS | | LIMITED DEMOLITION TO DETERMINE THE EXISTING STRUCTURAL | | CONNECTIONS. A SEPARATE APPLICATION, PERMIT AND REVIEWS | | WILL BE REQUIRED TO SHOW THE CONVERSION OF THE GARAGE | | TO AN APARTMENT OR ACCESSORY STRUCTURE. | | | | NOTE: | | | | ACCORDING TO CITY RECORDS, THIS STRUCTURE WAS | | ORIGINALLY CONSTRUCTED AS A DETACHED GARAGE. IT WAS | | CONVERTED TO AN APARTMENT WITH A KITCHEN, BEDROOM AND | | BATHROOM WITHOUT THE REQUIRED PERMITS OR INSPECTIONS. | | UNDER THE 2010 FBC EXISTING BUILDING THIS IS CONSIDERED | | A CHANGE OF OCCUPANCY. IN ORDER FOR THIS STRUCTURE-TO | | BE BROUGHT INTO COMPLIANCE, IT WILL BE REQUIRED TO | | COMPLY WITH THE 2010 FBC EXISTING BUILDING FOR A CHANGE | | OF OCCUPANCY FROM A UTILITY TO AN R-3 OCCUPANCY. THIS | | CHANGE IS FROM A LOWER HAZARD CATEGORY TO A HIGHER ONE. | | THEREFORE, THE FOLLOWING ITEMS WILL NEED TO BE BROUGHT | | INTO COMPLIANCE. THE STRUCTURE WILL BE REQUIRED TO | | COMPLY WITH THE 2010 FBCR WINDLOAD REQUIREMENTS FOR THE | | BUILDING ENVELOPE ( IN ADDITION TO GRAVITY LOADS), | | PRODUCT APPROVALS FOR EXTERIOR DOORS AND WINDOWS, | | EGRESS REQUIREMENTS, LIGHT AND VENTILATION, SMOKE AND | | CARBON MONOXIDE ALARMS, FIRE PROTECTION REQUIREMENTS | | (SEPARATION DISTANCE AND ALLOWABLE OPENINGS), THE | | REQUIREMENTS OF THE 2010 FBC ENERGY CONSERVATION, THE | | REQUIREMENTS OF THE 2010 FBCR MECHANICAL, THE | | REQUIREMENTS OF THE 2010 FBCR PLUMBING AND THE | | ELECTRICAL SYSTEM WILL BE REQUIRED TO COMPLY WITH THE | | 2008 NATIONAL ELECTRICAL CODE. THE PLANS WILL NEED TO | | SHOW HOW THE GARAGE WILL BE CONVERTED TO HABITABLE | | SPACE IN COMPLIANCE WITH THE 2010 FBC AND 2008 NEC. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2014-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-03 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-03 |
Time |
13:56 |
Sent To |
|
|
Notes |
2014-03-03 13:58:35 | NO ELECTRICAL WORK IS SPECIFIED AS PART OF THIS PERMIT. | | A SEPARATE APPLICATION, PERMIT AND REVIEW IS REQUIRED | | FOR ELECTRICAL WORK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-03 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-01-13 |
Time |
17:34 |
Sent To |
|
|
Notes |
2014-01-17 17:35:17 | TO SK DESK | | | 2014-01-13 17:35:17 | INCOMING SENT <$5K BUILD BOX. JW |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2014-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-03 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-03 |
Time |
12:45 |
Sent To |
|
|
Notes |
2014-03-03 12:55:03 | THE SCOPE OF THIS PERMIT IS TO DO SOME EXPLORATORY | | DEMOLISION TO DETERMINE THE EXISTING STRUCTURAL | | CONNECTIONS. THERE IS AN IMPACT FEE REVIEW STAMP ON TWO | | OF THE PLANS THAT WERE SUBMITTED. BE SURE TO SUBMIT | | THESE STAMPED PLANS WHEN YOU APPLY FOR THE PERMIT TO | | CONVERT THE GARAGE TO HABITABLE SPACE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2014-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-03 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-03 |
Time |
12:44 |
Sent To |
|
|
Notes |
2014-03-03 13:59:37 | NO MECHANICAL WORK IS SPECIFIED AS PART OF THIS PERMIT. | | A SEPARATE APPLICATION, PERMIT AND REVIEW IS REQUIRED | | FOR MECHANICAL WORK. | | | | 2010 FBC | | | | DENIED BY MECHANICAL | | | | 1) SUBMIT TWO SETS OF EQUIPMENT SIZING CALCULATIONS FOR | | THE HEATING/COOLING EQUIPMENT. FBCR M1401.3 | | | | 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE MECHANICAL | | PLANS THAT MATCHES THE SIZING CALCULATIONS. CITY | | AMENDMENTS 107.3.5.3 | | | | 3) SPECIFY THE DUCT LOCATION AND SIZES, THE GRILL SIZES | | AND CFMS AT EACH SUPPLY OUTLET, SHOW LOCATION AND SIZE | | OF RETURN DUCTS AND GRILLS. CITY AMENDMENTS 107.3.5.3 | | | | 4) SHOW THE LOCATION OF THE HVAC EQUIPMENT ON THE | | PLANS. CITY AMENDMENTS 107.3.5.3 | | | | 5) SHOW THE A/C DISCONNECTS AND EQUIPMENT SERVICING | | RECEPTACLE OUTLET ON THE PLANS. NEC 422.31 AND 210.63 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2014-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-03 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-03 |
Time |
09:50 |
Sent To |
|
|
Notes |
2014-03-03 11:06:24 | NO PLUMBING WORK IS SPECIFIED AS PART OF THIS PERMIT. A | | SEPARATE APPLICATION, PERMIT AND REVIEW IS REQUIRED FOR | | PLUMBING WORK.2010 FBC | | | | DENIED BY PLUMBING | | | | 1) THE BATHROOM FIXTURES ARE NOT PROPERLY VENTED. THERE | | ARE TWO WET-VENTED FIXTURE DRAINS DISCHARGING UPSTREAM | | OF THE DRY-VENTED FIXTURE DRAIN CONNECTION. THIS IS NOT | | ALLOWED BY CODE. SEE FBCR P3108.2.1 | | | | 2) THE PLUMBING RISER DIAGRAM DOES NOT MATCH THE FLOOR | | PLAN. THE DRAINS FOR THE CLOTHES WASHER AND THE KITCHEN | | SINK ARE NOT SHOWN. CITY AMENDMENTS 107.2.1 AND | | 107.3.5.3 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
N |
Date |
2014-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-03 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-03 |
Time |
15:18 |
Sent To |
|
|
Notes |
2014-03-03 15:22:53 | THE ZONING COMMENTS FROM THE FIRST REVIEW WILL NEED TO | | BE ADDRESSED WHEN APPLICATIONS ARE MADE FOR SEPARATE | | PERMITS TO CONVERT THE GARAGE TO LIVING SPACE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2014-01-28 |
|
|
Cont ID |
|
Sent By |
dkittred |
Date |
2014-01-27 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
dkittred |
Date |
2014-01-27 |
Time |
15:26 |
Sent To |
|
|
Notes |
2014-01-27 17:10:17 | 1/27/14 - SENT BACK TO R06 | | | 2014-01-27 17:09:38 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | 1/27/14 | | | | PERMIT IS UNCLEAR IF AS-BUILTS ARE DEPICTING A | | RECREATION ROOM OR ACCESSORY APARTMENT (SEE OPTIONS | | BELOW). PROPERTY IS APPROX. 5,000 SQ. FT. WITH A WIDTH | | OF 50 FT. IN THE MF20 ZONING DISTRICT. AN ACCESSORY | | APARTMENT IS NOT PERMITTED. PLEASE CLARIFY THE REQUEST. | | | | OPTION 1 - STRUCTURE CAN BE UTILIZED AS A DETACHED | | BEDROOM FROM THE MAIN HOUSE WITH BATHROOM, BUT NO | | KITCHEN. THIS SPACE CAN NOT BE RENTED SEPARATELY FROM | | THE MAIN HOUSE. A MICROWAVE, UNDERCOUNTER REFRIGERATOR, | | AND/OR SMALL SINK WOULD ALL BE PERMITTED AND NOT | | CLASSIFIED AS A KITCHEN. | | | | OPTION 2 - THE STRUCTURE CAN BE USED AS A RECREATION | | ROOM, BUT PLANS SHOULD MORE CLEARLY INDICATE AS SUCH AS | | THE PLANS SHOW A BEDROOM, BATHROOM, AND KITCHEN AREA. | | | | PLEASE FEEL FREE TO CALL AND DISCUSS BEFORE RESUBMITTAL | | TO MAKE SURE THE REVISION WILL PASS ZONING REVIEW. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | DANIELLE J. KITTREDGE, AICP | | SENIOR PLANNER | | PLANNING & ZONING DIVISION | | PHONE: (561)-822-1443 | | EMAIL: [email protected] | | | 2014-01-27 14:35:36 | 1/27/14 |
|
|