Plan Review Stops For Permit 14010016 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2014-01-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-01-02 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-01-02 |
Time |
13:38 |
Sent To |
|
|
Notes |
2014-01-02 13:39:20 | OTHER PORTIONS OF ROOF WERE APPROVED IN 2008. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2014-01-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-01-02 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-01-02 |
Time |
13:19 |
Sent To |
|
|
Notes |
2014-01-02 13:23:13 | IT APPEARS FROM THE SUBMITTED DRAWING THAT THE ENTIRE | | ROOF CONSTITUTES ONE ROOF SECTION AND THIS APPLICATION | | IS TO REPLACE MORE THAN 25% OF THE ROOF COVERING. THIS | | IS NOT ALLOWABLE BASED UPON THE SECTION BELOW. | | FBC EXISTING BUILDINGS - 611.1.1 - NOT MORE THAN 25 | | PERCENT OF THE TOTAL ROOF AREA OR ROOF SECTION OF ANY | | EXISTING BUILDING OR STRUCTURE SHALL BE REPAIRED, | | REPLACED OR RECOVERED IN ANY 12 MONTH PERIOD UNLESS THE | | ENTIRE ROOFING SYSTEM OR ROOF SECTION CONFORMS TO | | REQUIREMENTS OF THIS CODE. | | STEVEN KENNEDY | | 561 805 6710 | | [email protected] | | |
|
|
|