Plan Review Details - Permit 13120825
Plan Review Stops For Permit 13120825
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2014-07-08 Cont ID  
Sent By jwitmer Date 2014-07-08 Time 11:37 Rev Time 0.00
Received By jwitmer Date 2014-07-08 Time 10:25 Sent To  
Notes
2014-07-08 11:36:57BUILDING PLAN REVIEW
 PERMIT: 13120825
 ADD: 5731 PREMIER PARK RD.
 CONT: ZIRKELBACH CONSTRUCTION
 TEL: (864)300-1013
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW- NUCOR BUILDING SYSTEMS DATE STAMPED MAY
 16/2014
 DATE: TUES. JULY 08/2014
 ACTION: DENIED
  
 1) PLEASE SUBMIT THIS PACKAGE FOR THE DESIGNER OF
 RECORD APPROVAL. FL 61G1-23.015 (2) THE ARCHITECT IS
 RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL PROJECT
 DATA, REPORTS, SHOP DRAWINGS ETC..
 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31),(D) ROOFING PRODUCTS AND ASSEMBLIES
  
 2) UNDER THE ORIGINAL BUILDING PERMIT THE ROOFING
 APPROVAL NOA 12-0814.10 NUCOR BUILDING SYSTEMS
 STRUCTURAL VR-16-II VICELOC 360 GALVALUME STEEL ROOF
 SYSTEM WAS SUBMITTED.
 IN THIS SUBMITTAL PACKAGE NUCOR LIST (2) ROOFING
 PRODUCTA CFR ROOF (FL4891.1) & CLASSIC ROOF (FL4891.2)
 THERE IS NO MIAMI-DADE NOA LISTED IN THE PACKAGE.
 PLEASE SUBMIT THESE PRODUCT APPROVALS SO THE DESIGN
 PROFESSIONAL AND REVIEW THE DESIGN PRESSURES & SPANS
 ASSOCIATED WITH EACH OF THESE PRODUCTS AS WELL AS THE
 STRUCTURAL SSTELL FRAMING MEMBERS AND PURLIN SPACING
 FOR CODE COMPLIANCE.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2014-04-17 Cont ID  
Sent By jwitmer Date 2014-04-17 Time 18:53 Rev Time 0.00
Received By jwitmer Date 2014-04-17 Time 17:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2014-04-11 Cont ID  
Sent By jwitmer Date 2014-04-11 Time 18:19 Rev Time 0.00
Received By jwitmer Date 2014-04-11 Time 17:02 Sent To  
Notes
2014-03-29 11:40:00 
 BUILDING PLAN REVIEW
 PERMIT: 13120825
 ADD: 5731 PREMIER PARK RD.
 CONT: ZIRKELBACH CONSTRUCTION
 TEL: (864)300-1013
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: FRI. APRIL 11/2014
 ACTION: DENIED
  
 1A) COMPLIED.RESIDENT INSPECTOR AGREEMENT FILED UNDER
 THE FOUNDATION PERMIT # 14020271.
 THIS PROJECT BEING TILT-WALL CONSTRUCTION WILL REQUIRE
 A RESIDENT INSPECTOR. 2010 WEST PALM BEACH AMENDMENTS
 TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION, 2010 EDITION* 110.3.9 RESIDENT
 INSPECTOR.
 SUBMIT INSPECTOR RESUME' AND LICENSE DOCUMENTS TO KEN
 CONRAD, MANAGER OF THE RESIDENT INSPECTOR PROGRAM. A
 RESIDENT INSPECTOR PROGRAM IS REQUIRED, ON THIS
 PROJECT, DUE TO ONE OR MORE OF THE FOLLOWING:
 - BUILDINGS/ADDITIONS OF TYPE I OR II CONSTRUCTION
 - ANY MAJOR STRUCTURAL ALTERATIONS
 - STRUCTURES IN WHICH THE CONCRETE DESIGN IS BASED ON
 COMPRESSIVE STRENGTH (F'C) IN EXCESS OF 3000 PSI
 - BUILDINGS OVER 20,000 SQ FT IN AREA
 - BUILDING/STRUCTURES OF UNUSUAL DESIGN OR METHODS OF
 CONSTRUCTION (TILT WALL DESIGN).
  
 KEN CONRAD CONTACT INFORMATION:
 TEL: 561-805-6666
 E-MAIL: [email protected]
  
 RESIDENT INSPECTOR BOOKLET & FORMS WERE E-MAILED TO
 ANTHONY CAMPANO AT [email protected]
 1/06/2014 07:46 AM.
 SUCH INSPECTORS SHALL BE ADEQUATELY PRESENT AT TIMES
 WORK IS UNDERWAY ON THE STRUCTURAL ELEMENTS OF THE
 BUILDING. SUCH INSPECTORS SHALL BE A REGISTERED
 ARCHITECT, OR ENGINEER, OR A PERSON LICENSED UNDER
 CHAPTER 468, PART XII, FLORIDA STATUTES. SUCH
 INSPECTORS SHALL SUBMIT WEEKLY PROGRESS REPORTS
 INCLUDING THE DAILY INSPECTIONS TO THE BUILDING
 OFFICIAL, AND INCLUDING A CODE COMPLIANCE OPINION OF
 THE RESIDENT INSPECTOR.
  
 AT THE COMPLETION OF THE CONSTRUCTION WORK OR PROJECT,
 SUCH INSPECTORS SHALL SUBMIT A CERTIFICATE OF
 COMPLIANCE TO THE BUILDING OFFICIAL, STATING THAT THE
 WORK WAS DONE IN COMPLIANCE WITH THIS CODE AND IN
 ACCORDANCE WITH THE PERMITTED DRAWING. FINAL INSPECTION
 SHALL BE MADE BY THE BUILDING OFFICIAL BEFORE A
 CERTIFICATE OF OCCUPANCY OR CERTIFICATE OF COMPLETION
 IS ISSUED; AND CONFIRMATION INSPECTIONS MAY BE MADE AT
 ANY TIME TO MONITOR ACTIVITIES AND RESIDENT INSPECTORS.
  
 1B) 3RD REQUEST, SINCE THIS PROJECT WILL REQUIRE A
 RESIDENT INSPECTOR (3) SETS OF PLANS, AND PRODUCT
 APPROVALS WILL BE REQUIRED
 A 3RD SET OF PLANS WAS SUBMITTED MARCH 24/ 2014 MISSING
 THE STRUCTURAL SHEETS.
  
 1C) 4/11/2014 3 SETS OF FIRE SPRINKLER PLANS SUBMITTED
 TODAY, THEY ARE SIGNED AND SEALED COPIES SIGNATURES NOT
 ORIGINAL. PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND BEING
 FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE
 DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS
 .
  
 2-4) COMPLIED
  
 5) 3RD REQUEST.
 MISSING IN THE STRUCTURAL DESIGN ROOF FRAMING AND ROOF
 DECK DESIGN, PART OF THE BUILDING ENVELOPE. * 2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, ADMINISTRATION, 2010 EDITION 107.3.5.1.1(8)
 MINIMUM REQUIREMENTS FOR COMMERCIAL PLAN REVIEW,
 BUILDING ENVELOPE/ ROOF FRAMING/ ROOF SYSTEMS.
  
 SHEET S-101 DOES HAVE A ROOF DESIGN CRITERIA BUT THERE
 ARE NO DRAWINGS FROM PEMB WITH THE SUPPORTING ROOF
 FRAMING, ROOF DECK AND BUILDING ENVELOPE, COMPONENTS
 AND CLADDING.
  
 ROOFING PRODUCT APPROVALS WERE SUBMITTED NOA 12-0814.10
 NUCOR BUILDING SYSTEMS 0.30" MIN STRUCTURAL VR16-II
 VICE LOCK 360 GALVALUME STEEL ROOF PANEL SYSTEM.
 WITHOUT THE GIRT LAYOUT FROM PEMB SHOP DRAWINGS THIS
 ROOFING APPROVAL CAN NOT BE REVIEWED.
  
 ROOFING APPROVALS HAVE NOT BEEN STAMPED REVIEWED BY THE
 DESIGNER OF RECORD. 2010 FBC 107.3.4.1 PRODUCT
 APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE
 DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
  
 6) COMPLIED.
  
 7) 3RD REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING 2 COPIES OF
 PRODUCT APPROVALS WERE SUBMITTED, (3) REQUIRED FOR A
 RESIDENT INSPECTOR PROGRAM.
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 NOA 11-0912.06 OVERHEAD DOOR COMMERCIAL SECTIONAL STEEL
 GARAGE DOOR 10'-2" WIDE
 NOA 11-1222.02 OVERHEAD DOOR COMMERCIAL SECTIONAL STEEL
 GARAGE DOOR 14'-2" WIDE
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 NOA 12-0814.10 NUCOR BUILDING SYSTEMS 0.30" MIN
 STRUCTURAL VR16-II VICE LOCK 360 GALVALUME STEEL ROOF
 PANEL SYSTEM.
  
 8) 3RD REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE
 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 THE DESIGNER OF RECORD HAS NOT STAMPED THEIR APPROVAL
 WITH A SHOP DRAWING STAMP OF APPROVAL.
  
 9-12) COMPLIED>
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-02-22 Cont ID  
Sent By jwitmer Date 2014-02-22 Time 13:59 Rev Time 0.00
Received By jwitmer Date 2014-02-22 Time 13:00 Sent To  
Notes
2014-02-22 13:29:47BUILDING PLAN REVIEW
 PERMIT: 13120825
 ADD: 5731 PREMIER PARK RD.
 CONT: ZIRKELBACH CONSTRUCTION
 TEL: (864)300-1013
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: SAT. FEB. 22/2014
 ACTION: DENIED
  
 1A) COMPLIED.
 THIS PROJECT BEING TILT-WALL CONSTRUCTION WILL REQUIRE
 A RESIDENT INSPECTOR. 2010 WEST PALM BEACH AMENDMENTS
 TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION, 2010 EDITION* 110.3.9 RESIDENT
 INSPECTOR.
 SUBMIT INSPECTOR RESUME' AND LICENSE DOCUMENTS TO KEN
 CONRAD, MANAGER OF THE RESIDENT INSPECTOR PROGRAM. A
 RESIDENT INSPECTOR PROGRAM IS REQUIRED, ON THIS
 PROJECT, DUE TO ONE OR MORE OF THE FOLLOWING:
 - BUILDINGS/ADDITIONS OF TYPE I OR II CONSTRUCTION
 - ANY MAJOR STRUCTURAL ALTERATIONS
 - STRUCTURES IN WHICH THE CONCRETE DESIGN IS BASED ON
 COMPRESSIVE STRENGTH (F'C) IN EXCESS OF 3000 PSI
 - BUILDINGS OVER 20,000 SQ FT IN AREA
 - BUILDING/STRUCTURES OF UNUSUAL DESIGN OR METHODS OF
 CONSTRUCTION (TILT WALL DESIGN).
  
 KEN CONRAD CONTACT INFORMATION:
 TEL: 561-805-6666
 E-MAIL: [email protected]
  
 RESIDENT INSPECTOR BOOKLET & FORMS WERE E-MAILED TO
 ANTHONY CAMPANO AT [email protected]
 1/06/2014 07:46 AM.
 SUCH INSPECTORS SHALL BE ADEQUATELY PRESENT AT TIMES
 WORK IS UNDERWAY ON THE STRUCTURAL ELEMENTS OF THE
 BUILDING. SUCH INSPECTORS SHALL BE A REGISTERED
 ARCHITECT, OR ENGINEER, OR A PERSON LICENSED UNDER
 CHAPTER 468, PART XII, FLORIDA STATUTES. SUCH
 INSPECTORS SHALL SUBMIT WEEKLY PROGRESS REPORTS
 INCLUDING THE DAILY INSPECTIONS TO THE BUILDING
 OFFICIAL, AND INCLUDING A CODE COMPLIANCE OPINION OF
 THE RESIDENT INSPECTOR.
  
 AT THE COMPLETION OF THE CONSTRUCTION WORK OR PROJECT,
 SUCH INSPECTORS SHALL SUBMIT A CERTIFICATE OF
 COMPLIANCE TO THE BUILDING OFFICIAL, STATING THAT THE
 WORK WAS DONE IN COMPLIANCE WITH THIS CODE AND IN
 ACCORDANCE WITH THE PERMITTED DRAWING. FINAL INSPECTION
 SHALL BE MADE BY THE BUILDING OFFICIAL BEFORE A
 CERTIFICATE OF OCCUPANCY OR CERTIFICATE OF COMPLETION
 IS ISSUED; AND CONFIRMATION INSPECTIONS MAY BE MADE AT
 ANY TIME TO MONITOR ACTIVITIES AND RESIDENT INSPECTORS.
  
 1B) 2ND REQUEST, SINCE THIS PROJECT WILL REQUIRE A
 RESIDENT INSPECTOR (3) SETS OF PLANS, AND PRODUCT
 APPROVALS WILL BE REQUIRED.
  
 2) NOTIFICATION. * 2010 WEST PALM BEACH AMENDMENTS TO
 THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION,
 2010 EDITION 110.7 IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE
 PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE
 CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS
 PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT
 GRANTED BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS
 OR CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY
 OWNER. THIS INCLUDES, BUT IS NOT LIMITED TO, THE
 CONTROL OF DUST, NOISE, WATER OR DRAINAGE RUN-OFFS,
 DEBRIS, AND THE STORAGE OF CONSTRUCTION MATERIALS. NEW
 CONSTRUCTION ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL
 HISTORIC SURFACE
 WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, AND
 MAY REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE POSITIVE DRAINAGE
 PATTERNS OF THE AFFECTED SITES. ACCORDINGLY,
 DEVELOPERS, CONTRACTORS AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS,
 PATIOS, DRIVEWAYS, DECKS OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A SIGNIFICANT DECREASE OF
 PERMEABLE LAND AREA ON ANY PARCEL OR HAS ALTERED THE
 DRAINAGE FLOW ON THE DEVELOPED PROPERTY SHALL, AS A
 PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED
 DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A
 CERTIFICATION FROM A LICENSED PROFESSIONAL SHALL BE
 SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL
 OF THE FINAL INSPECTION.
  
 3) COMPLIED>
 THE STRUCTURAL SHEETS ENGINEERS SIGNATURE AND SEAL ARE
 ALL PHOTO-COPIES. PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND
 BEING FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE
 DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS
 EFFECTIVE DATE 05/06/2009
 (2)(A) EVERY SHEET OF PLANS AND PRINTS WHICH MUST BE
 SEALED UNDER THE PROVISIONS OF CHAPTER 471, F.S., SHALL
 BE SEALED, SIGNED AND DATED BY THE PROFESSIONAL
 ENGINEER IN RESPONSIBLE CHARGE.
  
 4) COMPLIED> SHEET S-101 THE WIND DESIGN CRITERIA NEEDS
 CORRECTIONS, THERE IS A DISCREPANCY BETWEEN THE
 BUILDING IMPORTANCE FACTOR (BUILDING CATEGORY 2) AND
 THE WIND VELCITY (160 ULTIMATE). WE AGREE THIS IS A
 BUILDING CATEGORY 2 BUT WITH A ULTIMATE VELOCITY OF 170
 MPH WIND VELOCITY , EXPOSURE C.
  
 5) 2ND REQUEST.
 MISSING IN THE STRUCTURAL DESIGN ROOF FRAMING AND ROOF
 DECK DESIGN, PART OF THE BUILDING ENVELOPE. * 2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, ADMINISTRATION, 2010 EDITION 107.3.5.1.1(8)
 MINIMUM REQUIREMENTS FOR COMMERCIAL PLAN REVIEW,
 BUILDING ENVELOPE/ ROOF FRAMING/ ROOF SYSTEMS.
  
 6) COMPLIED.
  
 7) 2ND REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (E) PRE-ENGINEERED A/C STANDS
  
 8) 2ND REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE
 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 9) 2ND REQUEST. SHEET A1.3 INDICATES THE EGRESS PLAN IS
 DESIGNED TO THE 2004 FBC-B, 2010 FBC- EXISTING
 BUILDING. 1001.1 SCOPE. AN ADDITION TO A BUILDING OR
 STRUCTURE SHALL COMPLY WITH THE FLORIDA BUILDING CODES
 AS ADOPTED FOR NEW CONSTRUCTION WITHOUT REQUIRING THE
 EXISTING BUILDING OR STRUCTURE TO COMPLY WITH ANY
 REQUIREMENTS OF THOSE CODES OR OF THESE PROVISIONS,
 EXCEPT AS REQUIRED BY THIS CHAPTER. WHERE AN ADDITION
 IMPACTS THE EXISTING BUILDING OR STRUCTURE, THAT
 PORTION SHALL COMPLY WITH THIS CODE.
  
 10) SHEET A3.1, CUT SECTION THRU NEW OFFICE WALLS,
 DETAIL # 2/ A8.2 :
 10A) COMPLIED.
 2010 FL EXISITNG BLDG CODE 1001.2 CREATION OR EXTENSION
 OF NONCONFORMITY. AN ADDITION SHALL NOT CREATE OR
 EXTEND ANY NONCONFORMITY IN THE EXISTING BUILDING TO
 WHICH THE ADDITION IS BEING MADE WITH REGARD TO
 ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, MEANS
 OF EGRESS, OR THE CAPACITY OF MECHANICAL, PLUMBING, OR
 ELECTRICAL SYSTEMS.
 THE COVER SHEET NOR A3.1 INDICATE HOW COMPLIANCE WITH
 OCCUPANCY SEPERATION IS OBTAINED AND COMPLIANCE WITH
 FBC-B TABLE 508.4.
  
 10B) 2ND REQUEST. THIS DETAIL INDICATES INSULATION IN
 THE WALL THAT SEPERATES THE STORAGE OCCUPANCY FROM THE
 OFFICE AREA. 2010 EXIST BLDG CODE LEVEL II ALTERATIONS:
 711.1 MINIMUM REQUIREMENTS. ALTERATIONS SUBJECT TO THIS
 CHAPTER SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, ENERGY CONSERVATION.101.4.1
 EXISTING BUILDINGS.
 EXISTING BUILDINGS SHALL MEET THE CRITERIA IN TABLE
 101.4.1 AS APPROPRIATE TO THE CONDITION DESCRIBED. IN
 TABLE 101.4.1 RENOVATION ENVELOPE TO MEET SECTION 502 .
 502.1.1.1 SHELL BUILDINGS, RENOVATIONS AND ALTERATIONS.
 THE BUILDING THERMAL ENVELOPE SHALL MEET THE
 REQUIREMENTS OF TABLE 502.1.1.1(1) OR TABLE
 502.1.1.1(2)
  
 10C) 2ND REQUEST. PROVIDE COMPLIANCE WITH 2010 ENERGY
 CODE 502.2.1.2 CEILING INSULATION. INSULATION INSTALLED
 ON A SUSPENDED CEILING WITH REMOVABLE CEILING TILES
 SHALL NOT BE CONSIDERED PART OF THE MINIMUM THERMAL
 RESISTANCE OF THE ROOF INSULATION UNLESS THE
 ROOF/CEILING CAVITY IS SEALED FROM THE EXTERIOR
 ENVIRONMENT.
 502.3.5.2 UNVENTED DROPPED CEILING CAVITIES.
 WHERE UNVENTED DROPPED CEILING CAVITIES OCCUR OVER
 CONDITIONED SPACES THAT DO NOT HAVE AN AIR BARRIER
 BETWEEN THE CONDITIONED AND UNCONDITIONED SPACE (SUCH
 AS T-BAR CEILINGS), THEY SHALL BE COMPLETELY SEALED
 FROM THE EXTERIOR ENVIRONMENT (AT THE ROOF PLANE) AND
 ADJACENT SPACES BY A CONTINUOUS AIR BARRIER THAT IS
 ALSO SEALED TO THE AIR BARRIER OF THE WALLS. IN THAT
 CASE, THE ROOF ASSEMBLY SHALL CONSTITUTE BOTH THE UPPER
 THERMAL ENVELOPE AND PRESSURE ENVELOPE OF THE BUILDING.
  
 11) 2ND REQUEST. SHEET A1.3 & A2.1 SHOW 2 NEW LOADING
 DOORS 27 & 28, SHEET A9.2 DETAIL # 3 INDICATES CONCRETE
 WALL PANELS WHERE DETAIL 1,6 & 10 APPEAR THEY ARE FOR
 METAL BUILDING?
 DISCREPANCY IN THE PLANS. 107.2.1.3. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-01-06 Cont ID  
Sent By jwitmer Date 2014-01-06 Time 10:49 Rev Time 0.00
Received By jwitmer Date 2014-01-06 Time 06:31 Sent To  
Notes
2014-01-06 08:07:42BUILDING PLAN REVIEW
 PERMIT: 13120825
 ADD: 5731 PREMIER PARK RD.
 CONT: ZIRKELBACH CONSTRUCTION
 TEL: (864)300-1013
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JAN. 06/2013
 ACTION: DENIED
  
 1A) THIS PROJECT BEING TILT-WALL CONSTRUCTION WILL
 REQUIRE A RESIDENT INSPECTOR. 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION, 2010 EDITION* 110.3.9 RESIDENT
 INSPECTOR.
 SUBMIT INSPECTOR RESUME' AND LICENSE DOCUMENTS TO KEN
 CONRAD, MANAGER OF THE RESIDENT INSPECTOR PROGRAM. A
 RESIDENT INSPECTOR PROGRAM IS REQUIRED, ON THIS
 PROJECT, DUE TO ONE OR MORE OF THE FOLLOWING:
 - BUILDINGS/ADDITIONS OF TYPE I OR II CONSTRUCTION
 - ANY MAJOR STRUCTURAL ALTERATIONS
 - STRUCTURES IN WHICH THE CONCRETE DESIGN IS BASED ON
 COMPRESSIVE STRENGTH (F'C) IN EXCESS OF 3000 PSI
 - BUILDINGS OVER 20,000 SQ FT IN AREA
 - BUILDING/STRUCTURES OF UNUSUAL DESIGN OR METHODS OF
 CONSTRUCTION (TILT WALL DESIGN).
  
 KEN CONRAD CONTACT INFORMATION:
 TEL: 561-805-6666
 E-MAIL: [email protected]
  
 RESIDENT INSPECTOR BOOKLET & FORMS WERE E-MAILED TO
 ANTHONY CAMPANO AT [email protected]
 1/06/2014 07:46 AM.
 SUCH INSPECTORS SHALL BE ADEQUATELY PRESENT AT TIMES
 WORK IS UNDERWAY ON THE STRUCTURAL ELEMENTS OF THE
 BUILDING. SUCH INSPECTORS SHALL BE A REGISTERED
 ARCHITECT, OR ENGINEER, OR A PERSON LICENSED UNDER
 CHAPTER 468, PART XII, FLORIDA STATUTES. SUCH
 INSPECTORS SHALL SUBMIT WEEKLY PROGRESS REPORTS
 INCLUDING THE DAILY INSPECTIONS TO THE BUILDING
 OFFICIAL, AND INCLUDING A CODE COMPLIANCE OPINION OF
 THE RESIDENT INSPECTOR.
  
 AT THE COMPLETION OF THE CONSTRUCTION WORK OR PROJECT,
 SUCH INSPECTORS SHALL SUBMIT A CERTIFICATE OF
 COMPLIANCE TO THE BUILDING OFFICIAL, STATING THAT THE
 WORK WAS DONE IN COMPLIANCE WITH THIS CODE AND IN
 ACCORDANCE WITH THE PERMITTED DRAWING. FINAL INSPECTION
 SHALL BE MADE BY THE BUILDING OFFICIAL BEFORE A
 CERTIFICATE OF OCCUPANCY OR CERTIFICATE OF COMPLETION
 IS ISSUED; AND CONFIRMATION INSPECTIONS MAY BE MADE AT
 ANY TIME TO MONITOR ACTIVITIES AND RESIDENT INSPECTORS.
  
 1B) SINCE THIS PROJECT WILL REQUIRE A RESIDENT
 INSPECTOR (3) SETS OF PLANS, AND PRODUCT APPROVALS WILL
 BE REQUIRED.
  
 2) * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 110.7 IMPACT OF CONSTRUCTION. ALL CONSTRUCTION ACTIVITY
 REGULATED BY THIS CODE SHALL BE PERFORMED IN A MANNER
 SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF ADJACENT
 PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO AFFECT
 SAID PROPERTY PURSUANT TO A CONSENT GRANTED BY THE
 APPLICABLE PROPERTY OWNER, UNDER TERMS OR CONDITIONS
 AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS
 INCLUDES, BUT IS NOT LIMITED TO, THE CONTROL OF DUST,
 NOISE, WATER OR DRAINAGE RUN-OFFS, DEBRIS, AND THE
 STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION
 ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL HISTORIC
 SURFACE
 WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, AND
 MAY REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE POSITIVE DRAINAGE
 PATTERNS OF THE AFFECTED SITES. ACCORDINGLY,
 DEVELOPERS, CONTRACTORS AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS,
 PATIOS, DRIVEWAYS, DECKS OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A SIGNIFICANT DECREASE OF
 PERMEABLE LAND AREA ON ANY PARCEL OR HAS ALTERED THE
 DRAINAGE FLOW ON THE DEVELOPED PROPERTY SHALL, AS A
 PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED
 DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A
 CERTIFICATION FROM A LICENSED PROFESSIONAL SHALL BE
 SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL
 OF THE FINAL INSPECTION.
  
 3) THE STRUCTURAL SHEETS ENGINEERS SIGNATURE AND SEAL
 ARE ALL PHOTO-COPIES. PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND
 BEING FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE
 DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS
 EFFECTIVE DATE 05/06/2009
 (2)(A) EVERY SHEET OF PLANS AND PRINTS WHICH MUST BE
 SEALED UNDER THE PROVISIONS OF CHAPTER 471, F.S., SHALL
 BE SEALED, SIGNED AND DATED BY THE PROFESSIONAL
 ENGINEER IN RESPONSIBLE CHARGE.
  
 4) SHEET S-101 THE WIND DESIGN CRITERIA NEEDS
 CORRECTIONS, THERE IS A DISCREPANCY BETWEEN THE
 BUILDING IMPORTANCE FACTOR (BUILDING CATEGORY 2) AND
 THE WIND VELCITY (160 ULTIMATE). WE AGREE THIS IS A
 BUILDING CATEGORY 2 BUT WITH A ULTIMATE VELOCITY OF 170
 MPH WIND VELOCITY , EXPOSURE C.
  
 5) MISSING IN THE STRUCTURAL DESIGN ROOF FRAMING AND
 ROOF DECK DESIGN, PART OF THE BUILDING ENVELOPE. * 2010
 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 107.3.5.1.1(8) MINIMUM REQUIREMENTS FOR COMMERCIAL PLAN
 REVIEW, BUILDING ENVELOPE/ ROOF FRAMING/ ROOF SYSTEMS.
  
 6) MISSING IN THE STRUCTURAL DESIGN 2010 FBC-B 1609.1.1
 DETERMINATION OF WIND DESIGN- CHAPTER 6 OF ASCE 7-10.
  
 6A) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 6B) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE
 TABLE 1609.2(2) .
  
 6C) PLEASE PROVIDE PRESSURES IN BOTH VASD & VULT. NOTE
 PRODUCT APPROVALS INDICATE PRESSURES IN VASD. 2010
 FBC-B 1609.1.5.
  
 7) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (E) PRE-ENGINEERED A/C STANDS
  
 8) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 9) SHEET A1.3 INDICATES THE EGRESS PLAN IS DESIGNED TO
 THE 2004 FBC-B, 2010 FBC- EXISTING BUILDING. 1001.1
 SCOPE. AN ADDITION TO A BUILDING OR STRUCTURE SHALL
 COMPLY WITH THE FLORIDA BUILDING CODES AS ADOPTED FOR
 NEW CONSTRUCTION WITHOUT REQUIRING THE EXISTING
 BUILDING OR STRUCTURE TO COMPLY WITH ANY REQUIREMENTS
 OF THOSE CODES OR OF THESE PROVISIONS, EXCEPT AS
 REQUIRED BY THIS CHAPTER. WHERE AN ADDITION IMPACTS THE
 EXISTING BUILDING OR STRUCTURE, THAT PORTION SHALL
 COMPLY WITH THIS CODE.
  
 10) SHEET A3.1, CUT SECTION THRU NEW OFFICE WALLS,
 DETAIL # 2/ A8.2 :
 10A) 2010 FL EXISITNG BLDG CODE 1001.2 CREATION OR
 EXTENSION OF NONCONFORMITY. AN ADDITION SHALL NOT
 CREATE OR EXTEND ANY NONCONFORMITY IN THE EXISTING
 BUILDING TO WHICH THE ADDITION IS BEING MADE WITH
 REGARD TO ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE
 SAFETY, MEANS OF EGRESS, OR THE CAPACITY OF MECHANICAL,
 PLUMBING, OR ELECTRICAL SYSTEMS.
 THE COVER SHEET NOR A3.1 INDICATE HOW COMPLIANCE WITH
 OCCUPANCY SEPERATION IS OBTAINED AND COMPLIANCE WITH
 FBC-B TABLE 508.4.
  
 10B) THIS DETAIL INDICATES INSULATION IN THE WALL THAT
 SEPERATES THE STORAGE OCCUPANCY FROM THE OFFICE AREA.
 2010 EXIST BLDG CODE LEVEL II ALTERATIONS: 711.1
 MINIMUM REQUIREMENTS. ALTERATIONS SUBJECT TO THIS
 CHAPTER SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, ENERGY CONSERVATION.101.4.1
 EXISTING BUILDINGS.
 EXISTING BUILDINGS SHALL MEET THE CRITERIA IN TABLE
 101.4.1 AS APPROPRIATE TO THE CONDITION DESCRIBED. IN
 TABLE 101.4.1 RENOVATION ENVELOPE TO MEET SECTION 502 .
 502.1.1.1 SHELL BUILDINGS, RENOVATIONS AND ALTERATIONS.
 THE BUILDING THERMAL ENVELOPE SHALL MEET THE
 REQUIREMENTS OF TABLE 502.1.1.1(1) OR TABLE
 502.1.1.1(2)
  
 10C) PROVIDE COMPLIANCE WITH 2010 ENERGY CODE 502.2.1.2
 CEILING INSULATION. INSULATION INSTALLED ON A SUSPENDED
 CEILING WITH REMOVABLE CEILING TILES SHALL NOT BE
 CONSIDERED PART OF THE MINIMUM THERMAL RESISTANCE OF
 THE ROOF INSULATION UNLESS THE ROOF/CEILING CAVITY IS
 SEALED FROM THE EXTERIOR ENVIRONMENT.
 502.3.5.2 UNVENTED DROPPED CEILING CAVITIES.
 WHERE UNVENTED DROPPED CEILING CAVITIES OCCUR OVER
 CONDITIONED SPACES THAT DO NOT HAVE AN AIR BARRIER
 BETWEEN THE CONDITIONED AND UNCONDITIONED SPACE (SUCH
 AS T-BAR CEILINGS), THEY SHALL BE COMPLETELY SEALED
 FROM THE EXTERIOR ENVIRONMENT (AT THE ROOF PLANE) AND
 ADJACENT SPACES BY A CONTINUOUS AIR BARRIER THAT IS
 ALSO SEALED TO THE AIR BARRIER OF THE WALLS. IN THAT
 CASE, THE ROOF ASSEMBLY SHALL CONSTITUTE BOTH THE UPPER
 THERMAL ENVELOPE AND PRESSURE ENVELOPE OF THE BUILDING.
  
 11) SHEET A1.3 & A2.1 SHOW 2 NEW LOADING DOORS 27 & 28,
 SHEET A9.2 DETAIL # 3 INDICATES CONCRETE WALL PANELS
 WHERE DETAIL 1,6 & 10 APPEAR THEY ARE FOR METAL
 BUILDING?
 DISCREPANCY IN THE PLANS. 107.2.1.3. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2014-08-13 Cont ID  
Sent By dhayes Date 2014-08-13 Time 10:04 Rev Time 0.00
Received By dhayes Date   Time 08:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-01-29 Cont ID  
Sent By albarran Date 2014-01-29 Time 20:01 Rev Time 0.00
Received By albarran Date 2014-01-29 Time 18:08 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2014-04-11 Cont ID  
Sent By wjolin Date 2014-04-11 Time 11:34 Rev Time 0.00
Received By wjolin Date 2014-04-11 Time 10:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2014-02-26 Cont ID  
Sent By wjolin Date 2014-02-26 Time 10:19 Rev Time 0.00
Received By wjolin Date 2014-02-26 Time 10:04 Sent To  
Notes
2014-02-26 10:19:215731 PREMIER PARK DRIVE
 PERMIT #13120825
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 REPEAT COMMENT - GENERAL: PROVIDE A PLAN SHOWING THE
 PROPOSED LAYOUT OF THE VEHICLES, BELT CONVEYORS,
 EQUIPMENT, ETC.
  
 REPEAT COMMENT - GENERAL: FOR ISSUANCE OF A GENERAL
 BUILDING PERMIT, SECTION 105.3.1.2(2) OF THE FLORIDA
 BUILDING CODE REQUIRES ENGINEER SEALED FIRE PROTECTION
 CONSTRUCTION DOCUMENTS FOR THE DESIGN OR ALTERATION OF
 50 OR MORE AUTOMATIC FIRE SPRINKLERS. PER FLORIDA
 ADMINISTRATIVE CODE SECTION 61G15-32.004, FIRE
 PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE
 POINT OF SERVICE FOR THE WATER SUPPLY, HYDRANT
 LOCATIONS, A LIST OF APPLICABLE NFPA STANDARDS
 APPLICABLE TO THE PROJECT, CLASSIFICATION OF HAZARD
 OCCUPANCY FOR EACH ROOM OR AREA, SUPPRESSION SYSTEM
 TYPE, DESIGN DENSITIES, WATER SUPPLY DATA (FIRE PUMP
 DATA, HYDRANT FLOW TEST DATA) AND ANY PERFORMANCE BASED
 INFORMATION SUCH AS PRE-ENGINEERED SYSTEMS.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2014-01-10 Cont ID  
Sent By wjolin Date 2014-01-10 Time 10:24 Rev Time 0.00
Received By wjolin Date 2014-01-10 Time 08:58 Sent To  
Notes
2014-01-10 10:23:285731 PREMIER PARK DRIVE
 PERMIT #13120825
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 GENERAL: PROVIDE A PLAN SHOWING THE PROPOSED LAYOUT OF
 THE VEHICLES, BELT CONVEYORS, EQUIPMENT, ETC.
  
 SHEET M1.1: PLAN INDICATES TWO CARBON MONOXIDE
 DETECTORS ON THE WEST AND CENTRAL AREA OF THE BUILDING
 ADDITION. AN ADDITIONAL DETECTOR MAY BE NEEDED ON THE
 EAST SIDE OF THE BUILDING.
  
 GENERAL: FOR ISSUANCE OF A GENERAL BUILDING PERMIT,
 SECTION 105.3.1.2(2) OF THE FLORIDA BUILDING CODE
 REQUIRES ENGINEER SEALED FIRE PROTECTION CONSTRUCTION
 DOCUMENTS FOR THE DESIGN OR ALTERATION OF 50 OR MORE
 AUTOMATIC FIRE SPRINKLERS. PER FLORIDA ADMINISTRATIVE
 CODE SECTION 61G15-32.004, FIRE PROTECTION ENGINEERING
 DOCUMENTS SHALL INCLUDE THE POINT OF SERVICE FOR THE
 WATER SUPPLY, HYDRANT LOCATIONS, A LIST OF APPLICABLE
 NFPA STANDARDS APPLICABLE TO THE PROJECT,
 CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR
 AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER
 SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA)
 AND ANY PERFORMANCE BASED INFORMATION SUCH AS
 PRE-ENGINEERED SYSTEMS.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status   Date   Cont ID  
Sent By dhayes Date   Time 08:51 Rev Time 0.00
Received By dhayes Date 2014-08-06 Time 08:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2014-07-08 Cont ID  
Sent By jwitmer Date 2014-07-08 Time 11:37 Rev Time 0.00
Received By jwitmer Date 2014-07-03 Time 09:40 Sent To  
Notes
2014-07-07 09:41:04SHOP DRAWINGS SENT TO JIM WITMER'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-04-11 Cont ID  
Sent By jwitmer Date 2014-04-11 Time 18:20 Rev Time 0.00
Received By jwitmer Date 2014-03-19 Time 13:43 Sent To  
Notes
2014-03-19 13:49:54C16
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-03-14 Cont ID  
Sent By hmoser Date 2014-03-14 Time 12:50 Rev Time 0.00
Received By hmoser Date 2014-02-06 Time 17:32 Sent To  
Notes
2014-02-07 17:33:22RESUBMITTAL SENT TO C16 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-03 Cont ID  
Sent By skennedy Date 2014-02-03 Time 15:02 Rev Time 0.00
Received By skennedy Date 2013-12-19 Time 16:58 Sent To  
Notes
2014-01-29 20:02:36SH DESK
  
2013-12-23 16:58:47SENT TO C9 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2014-02-28 Cont ID  
Sent By jwitmer Date 2014-02-22 Time 13:49 Rev Time 0.00
Received By jwitmer Date 2014-02-22 Time 13:49 Sent To  
Notes
2014-02-28 06:37:27IMPACT FEES PAID SEE FOUNDATION PLANS (14020271) STAMP
 BY PBC IMPACT FEE OFFICE. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-01-06 Cont ID  
Sent By jwitmer Date 2014-01-06 Time 06:32 Rev Time 0.00
Received By jwitmer Date 2014-01-06 Time 06:32 Sent To  
Notes
2014-01-06 06:33:08BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-03-14 Cont ID  
Sent By hmoser Date 2014-03-14 Time 12:50 Rev Time 0.00
Received By hmoser Date 2014-03-14 Time 12:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-02-03 Cont ID  
Sent By skennedy Date 2014-02-03 Time 15:00 Rev Time 0.00
Received By skennedy Date 2014-01-31 Time 09:44 Sent To  
Notes
2014-02-03 15:02:06PROVIDE OUTSIDE AIR PER FBC-M 403.2
 J SAEZ,
2014-01-31 09:46:24REVIEW BY JSAEZ PX 1328

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-01-28 Cont ID  
Sent By jwitmer Date 2014-01-28 Time 11:13 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2014-02-26 Cont ID  
Sent By eschneid Date 2014-02-26 Time 11:54 Rev Time 0.50
Received By eschneid Date 2014-02-26 Time 11:54 Sent To  
Notes
2014-02-26 13:31:34PASSED
  
 PLEASE NOTE THAT A D-CURB IS REQUIRED TO PROTECT ALL
 LANDSCAPE AREAS FROM VEHICULAR ENCROACHMENT AND THE
 CITY STANDARD IS ONE SIDED WHEEL STOPS.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2014-01-15 Cont ID  
Sent By eschneid Date 2014-01-15 Time 13:58 Rev Time 0.50
Received By eschneid Date 2014-01-15 Time 13:58 Sent To  
Notes
2014-01-15 14:34:11FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES TO THE COMMENTS:
  
 1) THIS PERMIT COVERS ONLY THE BUILDING CONSTRUCTION.
 SEPARATE PERMITS, WITH PLANS ARE REQUIRED FOR THE
 FOLLOWING:
  
 A. SITE DEMOLITION
 B. LANDSCAPE
 C. PARKING LOT CURBING AND STRIPING
 D. SITE LIGHTING RELOCATION
  
 2) PLEASE NOTE THAT A D-CURB IS REQUIRED TO PROTECT ALL
 LANDSCAPE AREAS FROM VEHICULAR ENCROACHMENT AND THE
 CITY STANDARD IS ONE SIDED WHEEL STOPS.
  
 3) THERE IS A DISCREPANCY BETWEEN THE WIDTH OF THE
 TRUCK PARKING AND LANDSCAPE AREA NORTH OF THE EXPANSION
 ON THE CIVIL SHEETS (45 FEET) AND THE ARCHITECTURAL
 SHEETS (44 FEET). PLEASE NOTE THAT THE APPROVED ZONING
 SITE PLAN SHOWS 44 FEET.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2014-01-02 11:54:271/2/13