Plan Review Details - Permit 13120507
Plan Review Stops For Permit 13120507
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2014-07-17 Cont ID  
Sent By jgomez Date 2014-07-17 Time 08:54 Rev Time 0.00
Received By jgomez Date 2014-07-17 Time 08:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2014-05-20 Cont ID  
Sent By jgomez Date 2014-05-19 Time 17:19 Rev Time 0.00
Received By jgomez Date 2014-05-19 Time 17:06 Sent To  
Notes
2014-05-19 17:18:20RESIDENTIAL (R3) GARAGE CONVERSION, THIRD CHECKLIST.
 CODE: 2010 FBC.
  
 1- WINDOWS AND DOORS PRODUCT APPROVALS SUBMITTED NOW
 ARE FOR VINYL PRODUCTS. THIS TYPE OF WINDOWS AND DOORS
 ARE NOT APPROVED BY HISTORIC. NEED TO PROVIDE PRODUCT
 APPROVAL (2 COPIES) AS REQUIRED BY DCA RULE 9N-3 FOR
 ANOTHER WINDOWS AND DOORS THAT ARE ACCEPTABLE FOR
 HISTORIC. SEE HISTORIC COMMENTS.
  
 ***NOTE: IF NEW PRODUCT APPROVALS SUBMITTED ARE FOR
 NON-IMPACT WINDOWS AND DOORS, THEN NEED TO PROVIDE
 STORM SHUTTERS PRODUCT APPROVAL AND COMPLETE
 INSTALLATION SCHEDULE.
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ABOVE PRODUCT APPROVALS. SEC. 107.3.4.1 OF CITY
 AMENDMENTS TO FBC.
  
 3- THE BEDROOM WINDOW DOESN'T COMPLY WITH THE EGRESS
 REQUIREMENTS OF SEC. R310.1.2 OF 2010 FBC-RESIDENTIAL.
 48"X48" SINGLE HUNG WINDOW DOESN'T PROVIDE THE REQUIRED
 24" MIN. CLEAR HEIGHT. REVISE AS REQUIRED.
  
 4- A) PROVIDE COMPLETE FRAMING DETAILS FOR THE NEW
 EXTERIOR OPENINGS, INCLUDING THE NEW DOUBLE FRENCH
 DOORS. SEC. R301.1. (REPEAT COMMENT. NOT ADDRESSED.
 ONLY DETAIL FOR WINDOW FRAMING WAS PROVIDED).
  
 B) NEW FRENCH DOORS OPENING: SPECIFY MASONRY OPENING
 VERTICAL REINFORCEMENT AS REQUIRED BY SEC. R609.3.2.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 C) PROVIDE COMPLETE STRUCTURAL BUCK DETAIL FOR NEW
 FRENCH DOORS AS REQUIRED BY SEC. R612.10.2.1. ***NOTE:
 BUCK SPECIFIED NEEDS TO PROVIDE FULL SUPPORT TO THE
 DOOR FRAME. (REPEAT COMMENT. NOT ADDRESSED).
  
 5- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 DUE. THEN, BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE. (REPEAT COMMENT. NOT ADDRESSED).
  
 6- SCOPE OF WORK IS TO CONVERT GARAGE TO LIVING SPACE,
 NOT TO REPLACE WINDOWS/DOORS AND MOVE BATHROOM
 LOCATION. VALUATION DECLARED IN THE PERMIT APPLICATION
 IS TOO LOW. UPDATE VALUATION TO INCLUDE ALL LABOR,
 MATERIALS, CONTRACTOR'S OVERHEAD/ PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 OF CITY
 AMENDMENTS. (REPEAT COMMENT. NOT ADDRESSED)
  
 ***NOTES:
 *PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-03-13 Cont ID  
Sent By jgomez Date 2014-03-13 Time 16:59 Rev Time 0.00
Received By jgomez Date 2014-03-13 Time 16:59 Sent To  
Notes
2014-03-13 17:04:15RESIDENTIAL (R3) GARAGE CONVERSION, SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: 2010 FBC.
  
 1- PLANS SUBMITTED NOW ARE MISSING THE ENGINEER'S SEAL.
 CHAPTER 471 FL. ST.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) HURRICANE SHUTTERS FOR WINDOWS THAT DON'T HAVE
 IMPACT GLAZING. (REPEAT COMMENT. NOT ADDRESSED).
  
 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL THE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 4- HURRICANE SHUTTERS: PROVIDE COMPLETE INSTALLATION
 SCHEDULE ( SEE CITY SAMPLE OF INSTALLATION SCHEDULE OR
 PROVIDE ANOTHER FORMAT THAT PROVIDES ALL THE
 INFORMATION).
 ***NOTE: CLEARLY IDENTIFY SPECIFIC MOUNTING CONDITIONS
 AND SPECIFIC ANCHOR TYPE AND SPACING TO BE USED. SEC.
 107.2.1 CITY AMENDMENTS. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 5- SHEET A-2:
 A) SHOW COMPLIANCE WITH THE EGRESS REQUIREMENTS FOR THE
 BEDROOM AS REQUIRED BY SEC. R310 OF 2010
 FBC-RESIDENTIAL. (NOTE: SHEET A-1 SHOWS EXISTING
 BEDROOM, THERE ARE NO PERMITS ON CITY RECORDS FOR THE
 CONVERSION). (REPEAT COMMENT. NOT ADDRESSED).
  
 B) PROVIDE COMPLIANCE WITH THE HEATING REQUIREMENTS OF
 SEC. R303.8 OF 2010 FBC-RESIDENTIAL. (REPEAT COMMENT.
 NOT ADDRESSED). FLOOR PLAN ONLY SHOWS AN A/C SHAFT NEXT
 TO THE CLOSET. NO A/C INFORMATION WAS PROVIDED).
  
 C) PROVIDE COMPLETE FRAMING DETAILS FOR THE NEW
 EXTERIOR OPENINGS, INCLUDING THE BEDROOM WINDOW AND NEW
 DOUBLE FRENCH DOORS. SEC. R301.1. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 D) NEW DOUBLE FRENCH DOOR: SPECIFY MASONRY OPENING
 VERTICAL REINFORCEMENT AS REQUIRED BY SEC. R609.3.2.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 E) REVISE EXTERIOR FRENCH DOORS NOTE #2. REVISE THE
 BUILDING EXPOSURE. IT'S EXPOSURE "C" NOT "B". (REPEAT
 COMMENT).
 ***NOTE: SAME COMMENT APPLIES TO WINDOWS NOTES. REVISE
 AS REQUIRED. (REPEAT COMMENT).
  
 F) REVISE ALL WINDOWS AND DOORS NOA NUMBER AND
 MANUFACTURER SPECIFIED ON THE FLOOR PLAN AND WINDOWS
 AND DOORS NOTES TO MATCH ACTUAL PRODUCT APPROVALS
 SUBMITTED FOR REVIEW. SEC. 107.2.1 CITY AMENDMENTS TO
 FBC.
  
 6- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 DUE. THEN, BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE. (REPEAT COMMENT. NOT ADDRESSED).
  
 7- SCOPE OF WORK IS TO CONVERT GARAGE TO LIVING SPACE,
 NOT TO REPLACE WINDOWS/DOORS AND MOVE BATHROOM
 LOCATION. VALUATION DECLARED IN THE PERMIT APPLICATION
 IS TOO LOW. UPDATE VALUATION TO INCLUDE ALL LABOR,
 MATERIALS, CONTRACTOR'S OVERHEAD/ PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 OF CITY
 AMENDMENTS.
  
 ***NOTES:
 *PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-01-16 Cont ID  
Sent By jgomez Date 2014-01-16 Time 09:02 Rev Time 0.00
Received By jgomez Date 2014-01-16 Time 08:17 Sent To  
Notes
2014-01-16 09:03:33RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- ENGINEER NEEDS TO USE CURRENT APPROVED SEAL AS
 REQUIRED BY SEC. 61G15-23.001 OF FLORIDA ADMINISTRATIVE
 CODE AND CHAPTER 471 FLORIDA STATUTE. CURRENT SEAL TO
 SAY "LICENSE" NOT CERTIFICATE".
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) FRENCH DOORS. NOA 08-0312.12 SUBMITTED EXPIRED ON
 MAY 25, 2011. NEED TO PROVIDE CURRENT NOA.
  
 B) SINGLE HUNG WINDOWS. NOA 06-0705.02 SUBMITTED
 EXPIRED ON JULY 12, 2011. NEED TO PROVIDE CURRENT NOA.
  
 C) HURRICANE SHUTTERS FOR WINDOWS AND DOORS THAT DON'T
 HAVE IMPACT GLAZING.
  
 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL THE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC.
  
 4- HURRICANE SHUTTERS: PROVIDE COMPLETE INSTALLATION
 SCHEDULE ( SEE CITY SAMPLE OF INSTALLATION SCHEDULE OR
 PROVIDE ANOTHER FORMAT THAT PROVIDES ALL THE
 INFORMATION).
 ***NOTE: CLEARLY IDENTIFY SPECIFIC MOUNTING CONDITIONS
 AND SPECIFIC ANCHOR TYPE AND SPACING TO BE USED. SEC.
 107.2.1 CITY AMENDMENTS.
  
 5- SHEET C-1:
 A) THE CURRENT CODE IS THE 2010 FBC, NOT THE 2007 FBC.
 REVISE AL THE INFORMATION ON PLANS THAT IS REFERENCING
 THE 2007 FBC.
  
 B) SPECIFY THE WIND DESIGN LOADS: ULTIMATE WIND SPEED
 AND THE NOMINAL WIND SPEED AS REQUIRED BY SEC.
 R301.2.1.3 OF 2010 FBC-RESIDENTIAL.
  
 C) SPECIFY THE BUILDING EXPOSURE. ACCORDING TO SEC.
 R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL, THIS BUILDING IS
 LOCATED IN EXPOSURE "C" NOT "B". COORDINATE WITH ITEM
 #7 BELOW.
  
 6- SHEET A-2:
 A) SHOW COMPLIANCE WITH THE EGRESS REQUIREMENTS FOR THE
 BEDROOM AS REQUIRED BY SEC. R310 OF 2010
 FBC-RESIDENTIAL. (NOTE: SHEET A-1 SHOWS EXISTING
 BEDROOM, THERE ARE NO PERMITS ON CITY RECORDS FOR THE
 CONVERSION).
  
 B) PROVIDE COMPLIANCE WITH THE HEATING REQUIREMENTS OF
 SEC. R303.8 OF 2010 FBC-RESIDENTIAL.
  
 C) PROVIDE COMPLETE FRAMING DETAILS FOR THE NEW
 EXTERIOR OPENINGS, INCLUDING THE NEW DOUBLE FRENCH
 DOORS. SEC. R301.1.
  
 D) SPECIFY OPENINGS VERTICAL REINFORCEMENT AS REQUIRED
 BY SEC. R609.3.2.
  
 E)REVISE EXTERIOR FRENCH DOORS NOTE #2. CURRENT ASCE IS
 ASCE 7-10 NOT ASCE 7-05. ALSO, REVISE THE WIND SPEED,
 EXPOSURE AND THE OPENINGS DESIGN PRESSURES. COORDINATE
 WITH ITEM # 5 ABOVE.
 ***NOTE: SAME COMMENT APPLIES TO WINDOWS NOTES. REVISE
 AS REQUIRED.
  
 7- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 DUE. THEN, BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 8- SCOPE OF WORK IS TO CONVERT GARAGE TO LIVING SPACE,
 NOT TO REPLACE WINDOWS/DOORS AND MOVE BATHROOM
 LOCATION. VALUATION DECLARED IN THE PERMIT APPLICATION
 IS TOO LOW. UPDATE VALUATION TO INCLUDE ALL LABOR,
 MATERIALS, CONTRACTOR'S OVERHEAD/ PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 OF CITY
 AMENDMENTS.
  
 ***NOTES:
 *PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2014-07-17 Cont ID  
Sent By skennedy Date 2014-07-17 Time 13:43 Rev Time 0.00
Received By skennedy Date 2014-07-17 Time 13:43 Sent To  
Notes
2014-07-17 10:34:26NEW SHEETS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2014-05-15 Cont ID  
Sent By skennedy Date 2014-05-15 Time 06:54 Rev Time 0.00
Received By skennedy Date 2014-05-15 Time 06:54 Sent To  
Notes
2014-05-15 07:08:08GENERAL AFTER THE FACT PERMITS
  
 PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY
 COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR
 INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL
 CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110
 & FBC 117.
  
 FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A
 PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY
 THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK
 SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION
 PURPOSES UNTIL APPROVED.
  
 FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR
 TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE
 TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN
 APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2014-03-13 Cont ID  
Sent By skennedy Date 2014-03-13 Time 14:42 Rev Time 0.00
Received By skennedy Date 2014-03-12 Time 12:44 Sent To B
Notes
2014-03-13 14:45:41PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 FBC- 107.3.5.3 PROVIDE AN ELECTRIC SERVICE RISER WITH
 WIRE SIZES, IF THE PANEL SHOWN IS A SUB PANEL, SHOW HOW
 FED. PROVIDE COMPLETE LOAD CALCULATIONS, PANEL
 SCHEDULES.
 NEC 406.11- PROVIDE TAMPER RESISTANT RECEPTACLES.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-02-05 Cont ID  
Sent By skennedy Date 2014-02-05 Time 09:30 Rev Time 0.00
Received By skennedy Date 2014-02-05 Time 09:20 Sent To  
Notes
2014-02-05 09:44:50PLEASE ADDRESS THE ITEMS NOTED BELOW:
 FBC- 107.3.5.3 PROVIDE AN ELECTRIC SERVICE RISER WITH
 WIRE SIZES, IF THE PANEL SHOWN IS A SUB PANEL, SHOW HOW
 FED. PROVIDE COMPLETE LOAD CALCULATIONS, PANEL
 SCHEDULES.
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 5 Status P Date 2014-07-02 Cont ID  
Sent By fmittner Date 2014-07-02 Time 15:38 Rev Time 0.00
Received By fmittner Date 2014-07-02 Time 15:38 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 4 Status F Date 2014-05-20 Cont ID  
Sent By fmittner Date 2014-05-20 Time 09:50 Rev Time 0.00
Received By fmittner Date 2014-05-20 Time 09:50 Sent To  
Notes
2014-05-20 09:50:53VINYL WINDOWS ARE NOT PERMITTED IN HISTORIC DISTRICTS.
 QUESTIONS CONTACT FRIEDERIKE MITTNER 822-1457

Review Stop HIST HISTORICAL
Rev No 3 Status F Date 2014-05-06 Cont ID  
Sent By fmittner Date 2014-05-06 Time 10:44 Rev Time 0.00
Received By fmittner Date 2014-05-06 Time 10:44 Sent To  
Notes
2014-05-06 10:44:50VINYL WINDOW PRODUCT NOT PERMITTED IN HISTORIC
 DISTRICT. QUESTIONS CONTACT FRIEDERIKE MITTNER, CITY
 HISTORIC PRESERVATION PLANNER AT 822-1457.
2014-04-28 12:43:28NEW SHEETS AND PRODUCT APPROVALS SUBMITTED. JG.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2014-02-28 Cont ID  
Sent By fmittner Date 2014-02-28 Time 10:54 Rev Time 0.00
Received By fmittner Date 2014-02-28 Time 10:54 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2013-12-12 Cont ID  
Sent By fmittner Date 2013-12-12 Time 11:28 Rev Time 0.00
Received By fmittner Date 2013-12-12 Time 11:28 Sent To  
Notes
2013-12-12 11:30:29FAILED FOR SAME REASONS LAST PERMIT (13080961) WAS
 DENIED. SCOPE OF WORK REQUIRES A CERTIFICATE OF
 APPROPRIATENESS. PVC WINDOWS NOT PERMITTED IN HISTORIC
 DISTRICTS WITHOUT BOARD APPROVAL. QUESTIONS CONTACT
 FRIEDERIKE MITTNER 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2014-07-29 Cont ID  
Sent By jgomez Date 2014-07-29 Time 13:29 Rev Time 0.00
Received By jgomez Date 2014-07-29 Time 13:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2014-07-17 Cont ID  
Sent By jgomez Date 2014-07-17 Time 14:11 Rev Time 0.00
Received By jgomez Date 2014-06-18 Time 18:38 Sent To  
Notes
2014-06-18 18:38:49INCOMING SENT TO ZONING. REQUIRES HISTORIC SIGN OFF. JW

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-05-20 Cont ID  
Sent By jgomez Date 2014-05-20 Time 14:21 Rev Time 0.00
Received By jgomez Date 2014-04-25 Time 16:28 Sent To  
Notes
2014-04-28 16:27:01RESUBMITTAL SENT TO R15 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-03-14 Cont ID  
Sent By jgomez Date 2014-03-14 Time 09:44 Rev Time 0.00
Received By jgomez Date 2014-03-12 Time 11:15 Sent To  
Notes
2014-03-12 11:16:08TO SK DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-02-05 Cont ID  
Sent By skennedy Date 2014-02-05 Time 09:45 Rev Time 0.00
Received By skennedy Date 2013-12-12 Time 10:04 Sent To  
Notes
2013-12-14 10:04:52R04

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 5 Status P Date 2014-07-29 Cont ID  
Sent By jgomez Date 2014-07-29 Time 13:41 Rev Time 0.00
Received By jgomez Date 2014-07-29 Time 13:41 Sent To  
Notes
2014-07-29 13:42:26NO FEES DUE. MU-2014-16266. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status F Date 2014-07-17 Cont ID  
Sent By jgomez Date 2014-07-17 Time 14:12 Rev Time 0.00
Received By jgomez Date 2014-07-17 Time 14:12 Sent To  
Notes
2014-07-17 14:34:027/17/14 TALKED TO PETER. TOLD HIM WE NEED THE PLANS
 STAMPED BY THE COUNTY. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2014-05-20 Cont ID  
Sent By jgomez Date 2014-05-20 Time 14:21 Rev Time 0.00
Received By jgomez Date 2014-05-20 Time 14:21 Sent To  
Notes
2014-05-20 14:21:371- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 DUE. THEN, BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE. (REPEAT COMMENT. NOT ADDRESSED).

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2014-03-14 Cont ID  
Sent By jgomez Date 2014-03-14 Time 09:45 Rev Time 0.00
Received By jgomez Date 2014-03-14 Time 09:45 Sent To  
Notes
2014-03-14 09:46:241- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 DUE. THEN, BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE. (REPEAT COMMENT. NOT ADDRESSED).

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-01-16 Cont ID  
Sent By jgomez Date 2014-01-16 Time 13:04 Rev Time 0.00
Received By jgomez Date 2014-01-16 Time 13:04 Sent To  
Notes
2014-01-16 13:07:181- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 DUE. THEN, BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2014-07-17 Cont ID  
Sent By jgomez Date 2014-07-17 Time 10:32 Rev Time 0.00
Received By jgomez Date 2014-07-17 Time 10:32 Sent To  
Notes
2014-07-17 10:33:337/17/14 PER PHONE CONVERSATION WITH PETER.
  
 MECHANICAL REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE COMPLETE AND CORRECT A/C PLAN AND AND
 EQUIPMENT SIZING CALCULATIONS UNDER A SEPARATE PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2014-05-20 Cont ID  
Sent By jgomez Date 2014-05-20 Time 10:39 Rev Time 0.00
Received By jgomez Date 2014-05-20 Time 10:39 Sent To  
Notes
2014-05-20 13:27:05RESIDENTIAL (R3) GARAGE CONVERSION, THIRD MECHANICAL
 REVIEW CHECKLIST.
 CODE: 2010 FBC.
  
 1- PROVIDE EQUIPMENT SIZING CALCULATIONS THAT COMPLY
 WITH SEC. 403.6 OF 2010 FBC-ENERGY CONSERVATION.
 A) NEED TO PROVIDE MANUAL J CALCULATIONS OR ANY OTHER
 APPROVED HEATING AND COOLING CALCULATION METHOD.
 CALCULATIONS SUBMITTED ARE NOT APPROVED BY THE FLORIDA
 BUILDING COMMISSION. CALCULATIONS TO INCLUDE THE
 MANUFACTURER AND MODEL NUMBER WITH THE SENSIBLE AND
 TOTAL COOLING CAPACITIES. EQUIPMENT CAPACITY CAN'T BE
 MORE THAN 1.15 TIMES GREATER THE TOTAL CALCULATED LOAD.
  
 2- A/C PLAN PROVIDED:
 A) SPECIFY ON THE A/C PLAN THE EQUIPMENT LISTED ON THE
 EQUIPMENT SIZING CALCULATIONS. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION.
  
 B) RETURN AIR GRILLE SHOWN BY THE SITTING ROOM DOESN'T
 SHOW ANY DUCTWORK. CLARIFY HOW IS IT CONNECTED TO THE
 AIR HANDLING UNIT. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2014-03-14 Cont ID  
Sent By jgomez Date 2014-03-14 Time 09:46 Rev Time 0.00
Received By jgomez Date 2014-03-14 Time 09:46 Sent To  
Notes
2014-03-14 09:52:48RESIDENTIAL (R3) GARAGE CONVERSION, SECOND MECHANICAL
 REVIEW CHECKLIST.
 CODE: 2010 FBC.
  
 ***REPEAT COMMENTS. NOT ADDRESSED.
  
  
 1- PROVIDE EQUIPMENT SIZING CALCULATIONS AS REQUIRED BY
 SEC. 403.6.1 OF 2010 FBC-ENERGY CONSERVATION.
  
 2- PROVIDE COMPLETE A/C PLAN AND SPECIFY EQUIPMENT
 LISTED ON THE EQUIPMENT SIZING CALCULATIONS. SEC.
 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-01-16 Cont ID  
Sent By jgomez Date 2014-01-16 Time 15:56 Rev Time 0.00
Received By jgomez Date 2014-01-16 Time 15:55 Sent To  
Notes
2014-01-16 15:57:10RESIDENTIAL (R3) ALTERATION, MECHANICAL REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE EQUIPMENT SIZING CALCULATIONS AS REQUIRED BY
 SEC. 403.6.1 OF 2010 FBC-ENERGY CONSERVATION.
  
 2- PROVIDE COMPLETE A/C PLAN AND SPECIFY EQUIPMENT
 LISTED ON THE EQUIPMENT SIZING CALCULATIONS. SEC.
 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 4 Status P Date 2014-07-17 Cont ID  
Sent By jgomez Date 2014-07-17 Time 10:53 Rev Time 0.00
Received By jgomez Date 2014-07-17 Time 10:52 Sent To  
Notes
2014-07-17 10:53:577/17/14 PER PHONE CONVERSATION WITH PETER:
  
 PLUMBING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE CORRECT PLUMBING RISER DIAGRAM UNDER A
 SEPARATE PERMIT.

Review Stop P PLUMBING
Rev No 3 Status P Date 2014-05-20 Cont ID  
Sent By jgomez Date 2014-05-20 Time 10:38 Rev Time 0.00
Received By jgomez Date 2014-05-20 Time 10:37 Sent To  
Notes
2014-07-17 10:42:56PLUMBING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE CORRECT PLUMBING RISER DIAGRAM.

Review Stop P PLUMBING
Rev No 2 Status F Date 2014-03-14 Cont ID  
Sent By jgomez Date 2014-03-14 Time 09:53 Rev Time 0.00
Received By jgomez Date 2014-03-14 Time 09:53 Sent To  
Notes
2014-03-14 09:54:45RESIDENTIAL (R3) GARAGE CONVERSION, SECOND PLUMBING
 REVIEW CHECKLIST.
 CODE: 2010 FBC.
  
 ****REPEAT COMMENT. NOT ADDRESSED.
  
  
 1- PROVIDE PLUMBING RISER DIAGRAM AS REQUIRED BY SEC.
 107.3.5.3 OF CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-01-16 Cont ID  
Sent By jgomez Date 2014-01-16 Time 15:49 Rev Time 0.00
Received By jgomez Date 2014-01-16 Time 15:49 Sent To  
Notes
2014-01-16 15:55:17RESIDENTIAL (R3) ALTERATION, PLUMBING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE PLUMBING RISER DIAGRAM AS REQUIRED BY SEC.
 107.3.5.3 OF CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2014-01-16 Cont ID  
Sent By jgomez Date 2014-01-16 Time 15:55 Rev Time 0.00
Received By jgomez Date 2014-01-16 Time 15:55 Sent To  
Notes
2014-01-16 15:56:07NO ROOF WORK SHOWN. JG.

Review Stop Z ZONING
Rev No 4 Status P Date 2014-07-02 Cont ID  
Sent By fmittner Date 2014-07-02 Time 15:37 Rev Time 0.00
Received By fmittner Date 2014-07-02 Time 15:37 Sent To  
Notes
2014-06-25 11:46:316/25/14
2014-06-19 12:59:376/19/14 ZONING SENT TO FM. SG

Review Stop Z ZONING
Rev No 3 Status P Date 2014-05-06 Cont ID  
Sent By fmittner Date 2014-05-06 Time 10:45 Rev Time 0.00
Received By fmittner Date 2014-05-06 Time 10:45 Sent To  
Notes
2014-05-06 10:45:43NO COOKING FACILITIES PERMITTED. NOT A SEPARATE LIVING
 QUARTER.
2014-04-28 12:43:01NEW SHEETS AND PRODUCT APPROVALS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 2 Status P Date 2014-02-28 Cont ID  
Sent By fmittner Date 2014-02-28 Time 10:54 Rev Time 0.00
Received By fmittner Date 2014-02-28 Time 10:54 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2013-12-12 Cont ID  
Sent By fmittner Date 2013-12-12 Time 11:30 Rev Time 0.00
Received By fmittner Date 2013-12-12 Time 11:30 Sent To B
Notes
2014-01-17 10:31:21CLARIFICATION: KITCHEN NOT PERMITTED IN ACCESSORY
 STRUCTURE. SINK ACCEPTABLE, NO COOKING FACLITIES.
2013-12-12 11:31:31MUST SUBMIT SURVEY AND SHOW THAT PROPERTY HAS ADEQUATE
 PARKING OFF SITE WITH LOSS OF GARAGE. QUESTIONS CONTACT
 FRIEDERIKE MITTNER 822-1457.