Plan Review Details - Permit 13120383
Plan Review Stops For Permit 13120383
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-02-03 Cont ID  
Sent By JWITMER Date 2014-02-03 Time 06:42 Rev Time 0.00
Received By jwitmer Date 2014-02-03 Time 05:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-01-13 Cont ID  
Sent By jwitmer Date 2014-01-10 Time 12:56 Rev Time 0.00
Received By jwitmer Date 2014-01-10 Time 12:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-02-05 Cont ID  
Sent By SKENNEDY Date 2014-02-05 Time 13:14 Rev Time 0.00
Received By dharvey Date 2014-02-05 Time 13:03 Sent To  
Notes
2014-02-05 13:04:10BY RL

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-01-13 Cont ID  
Sent By skennedy Date 2014-01-13 Time 16:45 Rev Time 0.00
Received By skennedy Date 2014-01-13 Time 16:43 Sent To  
Notes
2014-01-13 16:55:48PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 THE PLAN INDICATES PANEL LP3A LOCATED IN SUITE 302
 CONTROLS ELECTRICAL CUIRCUITS LOCATED IN SUITE 300 AND
 IN THE COMMON CORRIDOR UTILIZED FOR EGRESS.
 PER NEC 240.24 (A) & (B) PANELS SHALL BE LOCATED SUCH
 THAT OVER CURRENT DEVICES ARE ACCESSIBLE AND THAT
 OCCUPANTS SHALL HAVE ACCESS TO OCP DEVICES.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-01-27 Cont ID  
Sent By SCALDERO Date 2014-01-27 Time 13:52 Rev Time 0.00
Received By scaldero Date 2014-01-27 Time 13:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2014-01-06 Cont ID  
Sent By scaldero Date 2014-01-06 Time 16:13 Rev Time 0.00
Received By scaldero Date 2014-01-06 Time 16:13 Sent To  
Notes
2014-01-06 16:21:48PERMIT #13120383
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1) EMERGENCY LIGHTING IS NEEDED FOR THE OFFICES,
 CONFERENCE ROOM, AND RECEPTION AREA. EMERGENCY
 ILLUMINATION SHALL BE PROVIDED FOR A MINIMUM OF 1.5
 HOURS IN THE EVENT OF FAILURE OF NORMAL LIGHTING.
 EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO
 PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN AN
 AVERAGE OF 1 FT-CANDLE AND, AT ANY POINT, NOT LESS THAN
 0.1 FT-CANDLE, MEASURED ALONG THE PATH OF EGRESS AT
 FLOOR LEVEL.
  
 2) PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND
 DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF
 NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE
 REMOVED FROM THE SITE DAILY. SMOKING SHALL BE
 PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL
 OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE
 RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED.
  
 3) PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) OR IN WRITING (FAX:
 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE
 MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.?
  
 4) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
  
 5) PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
  
 SUE ELLEN CALDERON
 FIRE INSPECTOR & INVESTIGATOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-03-11 Cont ID  
Sent By hmoser Date 2014-03-11 Time 14:42 Rev Time 0.00
Received By hmoser Date 2014-01-23 Time 11:31 Sent To  
Notes
2014-01-24 11:34:55B28

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-01-13 Cont ID  
Sent By skennedy Date 2014-01-13 Time 16:57 Rev Time 0.00
Received By skennedy Date 2013-12-10 Time 09:51 Sent To  
Notes
2013-12-11 09:46:22SENT TO B30 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-03-11 Cont ID  
Sent By HMOSER Date 2014-03-11 Time 14:42 Rev Time 0.00
Received By hmoser Date 2014-03-10 Time 15:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-01-03 Cont ID  
Sent By shill Date 2013-12-19 Time 11:31 Rev Time 0.00
Received By hmoser Date 2014-01-03 Time 11:31 Sent To  
Notes
2014-01-03 11:31:46PLAN REVIEW BY J SAIS PX 1328
  
 1. PROVIDE FIRE DAMPER DETAIL
  
 2. PROVIDE HEAT LOAD CALCS
  
 3. HVAC DESIGN REQUIREMENTS
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-02-03 Cont ID  
Sent By LWAGNER Date 2014-02-03 Time 06:45 Rev Time 0.00
Received By jwitmer Date 2014-02-03 Time 06:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-12-19 Cont ID  
Sent By lwagner Date 2013-12-19 Time 13:57 Rev Time 0.00
Received By lwagner Date 2013-12-19 Time 11:00 Sent To  
Notes
2013-12-19 13:57:42FBC 2010 EXISTING BUILDING CODE
 FBC 2010 ACCESSIBILITY CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 1. A HI/LOW DRINKING FOUNTAIN WILL BE REQUIRED PER FBC
 ACCESSIBILITY
 211.2 MINIMUM NUMBER.
 NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
  
 2. THERE WILL NOT BE ENOUGH SPACE INSIDE AND ENOUGH
 CLEAR SPACE IN FRONT OF THE H/C SHOWER.
 608.2.1 TRANSFER TYPE SHOWER COMPARTMENTS.
 TRANSFER TYPE SHOWER COMPARTMENTS SHALL BE 36 INCHES
 (915 MM) BY 36 INCHES (915 MM) CLEAR INSIDE DIMENSIONS
 MEASURED AT THE CENTER POINTS OF OPPOSING SIDES AND
 SHALL HAVE A 36 INCH (915 MM) WIDE MINIMUM ENTRY ON THE
 FACE OF THE SHOWER COMPARTMENT. CLEARANCE OF 36 INCHES
 (915 MM) WIDE MINIMUM BY 48 INCHES (1220 MM) LONG
 MINIMUM MEASURED FROM THE CONTROL WALL SHALL BE
 PROVIDED.
  
 3. THE LAVITORY IS REQUIRED TO BE OUTSIDE OF THE 60"
 CLEAR SPACE FOR THE WATER CLOSET.
 604.3.1 SIZE.
 CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED
 PERPENDICULAR FROM THE REAR WALL.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status N Date 2013-12-19 Cont ID  
Sent By aaponte Date 2013-12-19 Time 16:29 Rev Time 0.00
Received By aaponte Date 2013-12-19 Time 16:29 Sent To  
Notes
2013-12-18 10:54:5112/18/13