2013-11-19 11:26:32 | |
| BUILDING PLAN REVIEW |
| PERMIT: 13110598 |
| ADD: 1306 8TH ST |
| CONT: J & M CONTRACTORS OF S. FLORIDA |
| TEL: (561 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUESDAY / NOV. 19/2013 |
| |
| ACTION: BUILDING PROVISO: |
| SLOPE: 3/12 |
| |
| 2010 FBC-R R905.2.7 UNDERLAYMENT APPLICATION. |
| FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS |
| HORIZONTAL (17-PERCENT SLOPE), UP TO FOUR UNITS |
| VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE), TWO |
| LAYERS OF UNDERLAYMENT COMPLYING WITH ASTM D 226 TYPE I |
| OR TYPE II, ASTM D 4869 TYPE I OR TYPE II, OR ASTM D |
| 6757 SHALL BE APPLIED IN THE FOLLOWING MANNER: |
| |
| 1. APPLY A MINIMUM 19-INCH-WIDE (483 MM) STRIP OF |
| UNDERLAYMENT FELT PARALLEL WITH AND STARTING AT THE |
| EAVES. |
| |
| 2. STARTING AT THE EAVE, APPLY 36-INCH-WIDE (914 MM) |
| SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19 |
| INCHES (483 MM). DISTORTIONS IN THE UNDERLAYMENT SHALL |
| NOT INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL. |
| |
| 3. END LAPS SHALL BE OFFSET BY 6 FEET (1829 MM). |
| |
| 4. CORROSION RESISTANT FASTENERS ARE TO BE APPLIED |
| ALONG THE OVERLAP AT A MAXIMUM SPACING OF 36 INCHES |
| (914 MM) ON CENTER. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |