2013-10-28 10:51:03 | BUILDING REVIEW COMMENTS TO SUBMITTAL ADDRESSING |
| PROVISO: |
| |
| ***NOTE: THERE WERE NOT REVISED DRAWINGS SUBMITTED AT |
| THIS TIME. ONLY PRODUCT APPROVALS AND ENERGY |
| CALCULATIONS*** |
| |
| |
| 1- ENERGY CALCULATIONS SUBMITTED MAIN HOUSE AND CABANA: |
| A) ENERGY CALCULATIONS AND PLANS NEED TO BE |
| COORDINATED. PLANS TO SHOW THE R-VALUE FOR WALLS, |
| CEILINGS AND FLOOR OVER OTHER SPACE. |
| SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. |
| |
| B) CALCULATIONS WERE SIGNED AND SEALED BY A |
| PROFESSIONAL ENGINEER. NEED ENGINEER'S ORIGINAL SEAL |
| AND SIGNATURE (NO COPY) AS REQUIRED BY CHAPTER 471 |
| FLORIDA STATUTE. |
| |
| C) REVISE DOOR TYPE TO MATCH PRODUCT APPROVALS. THERE |
| ARE NOT WOOD DOORS. |
| |
| 2- PROVIDE MANUFACTURER SPECS FOR THE ICYNENE |
| INSULATION. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 3- ENERGY CALCULATIONS ARE TAKING THE CEILING FANS |
| CREDIT. NEED PLANS TO SHOW FAN SIZES AS REQUIRED BY SEE |
| SEC. 405.6.6 OF 2010 FBC-ENERGY CONSERVATION. |
| |
| 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| DCA RULE 9N-3 FOR: |
| *A)ENTRY DOOR THAT MEETS THE ENGINEER CALCULATED |
| PRESSURES. INFORMATION SUBMITTED IS NOT A FLORIDA |
| PRODUCT APPROVAL AND DOESN'T MEET THE CALCULATED DESIGN |
| PRESSURES. |
| |
| ***NOTE; MANUFACTURER MAY APPLY FOR A LOCAL OR SITE |
| SPECIFIC PRODUCT APPROVAL IF THERE IS NOT A CURRENT |
| FLORIDA PRODUCT APPROVAL. COMPLETE ORIGINAL ENGINEERED |
| PACKAGE WILL BE REQUIRED FOR APPROVAL. |
| |
| B) SHUTTERS AS SHOWN ON PLANS. AND PROVIDE COMPLETE |
| INSTALLATION SCHEDULE. |
| |
| C) STORAGE STEEL DOOR. NEED COMPLETE PRODUCT APPROVAL |
| INCLUDING THE DRAWINGS. |
| |
| 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| ABOVE PRODUCT APPROVALS. SEC. 107.3.4.1 OF CITY |
| AMENDMENTS TO FBC. |
| |